Desa BHDV34PA, BHDV34NA installation manual General Venting, Location of Vent Termination

Page 5

OWNER’S MANUAL

PRE-INSTALLATION

PREPARATION

Continued

13"

9 1/4"

41"

29"

12 5/8"

34 3/8"

35 1/16"

58"

Figure 6 - Framing Clearances for Corner Installation

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

2

Note: There must be

 

 

 

 

 

 

 

a minimum clear-

A

 

 

3

ance of 18" above

 

 

 

top of louver

 

 

 

 

 

 

4

opening when

 

B

 

 

5

installing a television

 

 

 

or entertainment

 

 

 

 

C

6

center above the

 

 

 

 

 

 

 

 

 

D

fireplace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of Louver Opening

 

 

 

 

 

 

 

 

 

 

Ref.

 

Mantel Depth

 

Ref.

 

Mantel from Top

 

 

 

 

 

 

 

 

 

 

of Louver Opening

 

 

1

 

14" (356mm)

 

A

 

16" (406mm)

 

 

 

 

 

 

 

 

 

 

 

2

 

12" (305mm)

 

B

 

14" (356mm)

 

 

3

 

10" (254mm)

 

C

 

12" (305mm)

 

 

 

 

 

 

 

 

 

 

 

4

 

8" (203mm)

 

D

 

10" (254mm)

 

 

 

 

 

 

 

 

 

 

 

5

 

6" (152mm)

 

E

 

8" (203mm)

 

 

 

 

 

 

 

 

 

 

 

6

 

4" (101mm)

 

F

 

6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

7

 

2" (51mm)

 

G

 

4" (101mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 7 - Clearances for Combustible Mantels

Nailing Tabs

Wall

GENERAL VENTING

These models are approved for use with Simpson Dura-Vent 6 5/8" direct-vent pipe components and terminations as well as both flex and rigid Vanguard vent components.

Your fireplace is approved to be vented either through the side wall, or vertically using the following guidelines:

Only use Vanguard or Simpson Dura- Vent GS venting components or kits spe- cifically approved for this fireplace.

Minimum clearance between vent pipes and combustible materials is 1" (25 mm), except where stated otherwise.

Combustible material may be flush with the top front of fireplace with a maxi- mum thickness of 3/4".

Do not recess venting terminals into a wall or siding.

Install horizontal venting with a 1/4" rise for every 12" of run toward the termination.

You may paint the vent terminal with 450ºF (232ºC) heat-resistant paint to co- ordinate with the exterior finish.

There must not be any obstruction such

as bushes, garden sheds, fences, decks, or utility buildings within 24" from the front of the termination cap.

Do not locate termination cap where ex- cessive snow or ice build up may occur. Be sure to clear vent termination area af- ter snow falls to prevent accidental block- age of venting system. When using snow blowers, do not direct snow towards vent termination area.

LOCATION OF VENT

TERMINATION

When locating vent termination, it is impor- tant to observe the minimum clearances shown in Figure 8, page 6. You will avoid extra framing by positioning your fireplace against an already existing framing mem- ber. The sides of the fireplace may be posi- tioned directly against combustible walls.

*Check with local codes or with the current CAN/CGA B149 [.1 or .2] Installation Codes for Canada or the USA Installations follow the current National Fuel Gas Code, ANS Z223.1, also known as NFPA 54.

Continued

105981

5

Image 5
Contents Natural GAS Model BHDV34NA PROPANE/LP GAS Model BHDV34PA For Your SafetyFor Your Safety What to do if YOU Smell GAS DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingLocation of Vent Termination General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Vertical Rigid Venting Configuration Using Two 90 ElbowsVenting Installing Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610T Blowers Check GAS TypeSide View As a freestanding unit with an acInstallation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Close manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsInstalling Optional Wall Mount Switch GWMS2 Installing Optional Wall Mounted Thermostat GWMT1REMOVING/REPLACING Glass Door Installing 9-Volt Alkaline Battery into ReceiverInstalling 9-Volt Battery in Hand- Held Remote Control Unit Installing Left Side Brick Panel Installing Optional Brick Liner D8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersOperating Fireplace Ghrct Series Operation Operating Optional Blower AccessoryGhrc Series Operation Inspecting Burners Pilot AssemblyOperating Optional GWMT1 Wall Mounted Thermostat Burner Flame PatternGlass Door Cleaning and MaintenancePilot and Burners Venting SystemObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementWiring Diagram Replacement PartsTechnical Service Service HintsBHDV34NA BHDV34PA SpecificationsAccessories Duplex Outlet KIT Receiver and HAND-HELD Remote Control KIT Ghrc SeriesBrass Louver KIT Manual Blower KIT GA3700BHDV34NA BHDV34PA Illustrated Parts BreakdownDIRECT-VENT Fireplace BHDV34NA BHDV34PA Parts ListWarranty Information