Desa CHL3924NR installation manual Safety Information

Page 3

SAFETY INFORMATION

Continued

WARNING:Thisproductcon- tainsand/orgenerateschemicals known to the state of California to cause cancer or birth defects or other reproductive harm.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, op- erate or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explo- sion,electricalshockandcarbon monoxide poisoning.

DANGER: Carbon monoxide

poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with head- aches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.

Natural and Propane/LP Gas: Natural and pro- pane/LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warn- ings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not ap- proved for use with this heater.

WARNING: Do not allow fans toblowdirectly intothe fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Heater base assembly becomes veryhotwhenrunningheater.Keep children and adults away from hot surface to avoid burns or clothing ignition.Heaterwillremainhotfora time after shutdown.Allow surface to cool before touching.

Carefully supervise young chil- dren when they are in the room withheater.Whenusingthehand- held remote accessory, keep se- lector switch in the OFF position to prevent children from turning on burners with remote.

Keep the appliance area clear and free from combustible ma- terials, gasoline and other flam- mable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) in- side any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).

3.To prevent performance problems, the use of a propane/LP fuel tank of less than 100 lb. capacity is not recommended (propane/LP units only).

111161-01Hwww.desatech.com

Image 3
Contents Yellow Flame Model Shown 18, 24 and 30 Remote ReadySafety Information Table of ContentsSafety Information Local Codes Unpacking Product FeaturesRemote Control Accessories Product IdentificationDetermining if You Have a Confined or Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationMinimum Firebox Installation and ClearancesVent-Free Operation Only Minimum Fireplace Clearance To Combustible MaterialsMantel Clearances If Using Mantel15 to Installing Damper Clamp Accessory for Vented OperationFloor Clearances Chimney Minimum PermanentInstallation Items Needed Installing Heater Base AssemblyExternal Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Propane/LPNatural Installing Remote Receiver Unit Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Installing Wireless hand- Held Remote control AccessoryInstalling 9-Volt Battery in Receiver Installing Front Log #1 CCL3930PR/NR Shown Installing LogsInstalling Crossover Log #4 CCL3930PR/NR Shown For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance On/Off Series Model HRC101  MANUAL Lighting ProcedureOptional Hand-Held Remote OperationPilot Flame Pattern Inspecting BurnersMain burner Cleaning MaintenanceBurner Injector Holder and Pilot Air Inlet Hole LogsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, See Cleaning and Mainte See Checking Gas Connec Gas leak. See WarningModels CCL3018PR, CCL3018PRA, CCL3018NR and CCL3018NRA Illustrated Parts BreakdownParts List Models CCL3930NRA Description QTY Service Hints SpecificationsWiring Diagram Technical ServiceParts Central Replacement PartsParts Under Warranty Parts Not Under WarrantyFireplace Hood Receiver and HAND-HELD Thermostat Remote Control KIT HRC201Receiver and HAND-HELD Remote Control KIT HRC101 Equipment Shutoff Valve GA5010111161-01H Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

CHL3924NR specifications

Desa CHL3924NR is an innovative and versatile heating solution designed to meet the demands of modern living. This unit is particularly favored for its combination of efficiency, performance, and advanced technology, making it an ideal choice for homeowners looking for effective heating options.

One of the standout features of the Desa CHL3924NR is its impressive heating capacity. With a powerful design, it can deliver substantial warmth to medium to large spaces while maintaining a user-friendly operation. The unit boasts a range of heating settings, allowing users to customize the temperature according to their preferences and comfort. This flexibility not only enhances user experience but also optimizes energy consumption, contributing to lower utility bills.

Furthermore, the CHL3924NR incorporates cutting-edge technology to ensure reliable and efficient performance. The unit comes with a state-of-the-art digital thermostat that provides precise temperature control. This feature allows for easy monitoring and adjustment, ensuring that a comfortable environment is maintained effortlessly.

Energy efficiency is a hallmark of the Desa CHL3924NR. It is designed to minimize energy waste while maximizing output, making it an environmentally conscious choice. The unit's efficient fuel consumption means it operates with lower emissions compared to traditional heating systems, aligning with the growing trend towards sustainable living.

Durability is another significant characteristic of the Desa CHL3924NR. Constructed with high-quality materials, this heating unit is built to last, and its robust design can withstand the rigors of daily use. Coupled with a sleek, modern aesthetic, it seamlessly integrates into various home décors.

Safety features are paramount in the design of the CHL3924NR, ensuring peace of mind during operation. The unit is equipped with safety shut-off mechanisms, preventing overheating and potential hazards.

In conclusion, the Desa CHL3924NR stands out as a reliable, efficient, and stylish heating solution, perfect for contemporary homes. Its combination of advanced technology, user-friendly features, energy efficiency, and safety make it an excellent choice for anyone looking to enhance their heating experience. Whether for a cozy night in or providing warmth during colder months, the Desa CHL3924NR delivers exceptional performance that meets the needs of today’s consumers.