Desa CHL3924NR installation manual Inspecting Burners, Pilot Flame Pattern

Page 22

Operating heater

Continued

Manual Mode

1. Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2. Press the MANU button to turn on the fireplace.

3. Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1. Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2. Press AUTO button to select this mode.

3. Set the desired room temperature by press- ing the TEMP + or - buttons.

4. Press the POWER and LOCK buttons together to turn off the fireplace

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace.

Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1. If the average room temperature exceeds

82 degrees Fahrenheit (28 degrees Centi- grade), the hand-held remote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2. The receiver continuously receives signals from the hand-held remote to control the room temperature. If the hand-held remote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Key Pad Lock Feature

This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held remote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

Inspecting Burners

Check pilot flame pattern and burner flame pat- terns often.

PILOT FLAME PATTERN

Figure 36 shows a correct pilot flame pattern. Figure 37, shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 37

turn heater off (see To Turn Off Gas to Appli- ance, page 20)

see Troubleshooting, page 24

Note: The pilot flame on natural gas units will have a slight curve, but the flame should be blue and have no yellow or orange color.

Propane/LP

Pilot Burner

Natural Gas

Gas

 

 

Thermocouple

Figure 36 - Correct Pilot Flame Pattern

Pilot Burner

Pilot

Natural Gas

Propane/LP

Burner

Gas

 

 

Thermocouple

Figure 37 - Incorrect Pilot Flame Pattern

22

www.desatech.com

111161-01H

Image 22
Contents 18, 24 and 30 Remote Ready Yellow Flame Model ShownTable of Contents Safety InformationSafety Information Local Codes Product Identification Product FeaturesRemote Control Accessories UnpackingUnusually Tight Construction Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Check GAS TypeMinimum Fireplace Clearance To Combustible Materials Installation and ClearancesVent-Free Operation Only Minimum FireboxIf Using Mantel Mantel ClearancesChimney Minimum Permanent Installing Damper Clamp Accessory for Vented OperationFloor Clearances 15 toInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply External Regulator With Vent Pointing DownPropane/LP Checking GAS ConnectionsNatural Pressure Testing Heater Gas Connections Installing Remote Receiver UnitTest Pressures Equal To or Less Than Psig 3.5 kPa Accessory Installing Wireless hand- Held Remote controlInstalling 9-Volt Battery in Receiver Installing Logs Installing Front Log #1 CCL3930PR/NR ShownInstalling Crossover Log #4 CCL3930PR/NR Shown Operating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Remote Operation  MANUAL Lighting ProcedureOptional Hand-Held On/Off Series Model HRC101Inspecting Burners Pilot Flame PatternLogs Cleaning MaintenanceBurner Injector Holder and Pilot Air Inlet Hole Main burnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, See Cleaning and Mainte Gas leak. See Warning See Checking Gas ConnecIllustrated Parts Breakdown Models CCL3018PR, CCL3018PRA, CCL3018NR and CCL3018NRAParts List Models CCL3930NRA Description QTY Technical Service SpecificationsWiring Diagram Service HintsParts Not Under Warranty Replacement PartsParts Under Warranty Parts CentralEquipment Shutoff Valve GA5010 Receiver and HAND-HELD Thermostat Remote Control KIT HRC201Receiver and HAND-HELD Remote Control KIT HRC101 Fireplace Hood111161-01H Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters

CHL3924NR specifications

Desa CHL3924NR is an innovative and versatile heating solution designed to meet the demands of modern living. This unit is particularly favored for its combination of efficiency, performance, and advanced technology, making it an ideal choice for homeowners looking for effective heating options.

One of the standout features of the Desa CHL3924NR is its impressive heating capacity. With a powerful design, it can deliver substantial warmth to medium to large spaces while maintaining a user-friendly operation. The unit boasts a range of heating settings, allowing users to customize the temperature according to their preferences and comfort. This flexibility not only enhances user experience but also optimizes energy consumption, contributing to lower utility bills.

Furthermore, the CHL3924NR incorporates cutting-edge technology to ensure reliable and efficient performance. The unit comes with a state-of-the-art digital thermostat that provides precise temperature control. This feature allows for easy monitoring and adjustment, ensuring that a comfortable environment is maintained effortlessly.

Energy efficiency is a hallmark of the Desa CHL3924NR. It is designed to minimize energy waste while maximizing output, making it an environmentally conscious choice. The unit's efficient fuel consumption means it operates with lower emissions compared to traditional heating systems, aligning with the growing trend towards sustainable living.

Durability is another significant characteristic of the Desa CHL3924NR. Constructed with high-quality materials, this heating unit is built to last, and its robust design can withstand the rigors of daily use. Coupled with a sleek, modern aesthetic, it seamlessly integrates into various home décors.

Safety features are paramount in the design of the CHL3924NR, ensuring peace of mind during operation. The unit is equipped with safety shut-off mechanisms, preventing overheating and potential hazards.

In conclusion, the Desa CHL3924NR stands out as a reliable, efficient, and stylish heating solution, perfect for contemporary homes. Its combination of advanced technology, user-friendly features, energy efficiency, and safety make it an excellent choice for anyone looking to enhance their heating experience. Whether for a cozy night in or providing warmth during colder months, the Desa CHL3924NR delivers exceptional performance that meets the needs of today’s consumers.