Desa CHL3924NR  MANUAL Lighting Procedure, Optional Hand-Held, Remote Operation

Page 21

Operating heater

Continued

 MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 19.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions, page 20.

optional Hand-Held

REMOTE OPERATION

Note: HRC201 Hand-Held Remote Control Kit is included with CHL3924NR/PR models only. Hand-held remote control accessories must be purchased separately for all other models (see Accessories, page 34). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 19.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 33). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

Flame Adjustment

Control

Knob

 

 

Knob

 

 

ON

IH

 

PILOT

 

F

F

OFF

 

O

O

 

 

N

REMOTE

LO

 

 

 

 

 

Selector Switch in Remote Position

Figure 33 - Setting the Selector Switch,

Control Knob and Flame Adjustment

Knob for Remote Operation

On/Off Series (Model HRC101)

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 34).

To Lock press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

To Unlock press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Indicator

Control

Light

Button

 

Figure 34 - On/Off Hand-Held Remote

Control Unit (HRC101)

Thermostat Series (Model

HRC201)

The hand-held remote can be operated using either the manual mode (MANU) or thermo- static mode (AUTO) (see Figure 35). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.

 

 

 

 

Digital

 

 

 

 

Display

Locks

 

AUTO

Shows

ROOM

 

SET

Temperature

TEMP

 

TEMP

System to

 

 

 

and Settings

Prevent

LOCK

TEMP

POWER

Turns Hand-

Accidental

 

 

 

 

 

 

Held Remote

Ignition

 

 

 

 

 

 

On or Off and

 

MANU

ºC/ºF

AUTO

 

 

 

 

Allows You

Turns

 

 

 

to Choose

 

 

 

the Manual

Burners

 

 

 

Setting

On or Off

 

 

 

Selects AUTO

 

 

 

 

Increases or

 

 

 

Mode

 

 

 

 

Decreases Room

°C/°F Mode

Temperature in

 

 

 

 

AUTO Mode

Button

 

Figure 35 - Thermostat Hand-Held Remote Control Unit (HRC201)

111161-01H

www.desatech.com

21

Image 21
Contents Yellow Flame Model Shown 18, 24 and 30 Remote ReadySafety Information Table of ContentsSafety Information Local Codes Remote Control Accessories Product FeaturesProduct Identification UnpackingDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationVent-Free Operation Only Installation and ClearancesMinimum Fireplace Clearance To Combustible Materials Minimum FireboxMantel Clearances If Using MantelFloor Clearances Installing Damper Clamp Accessory for Vented OperationChimney Minimum Permanent 15 toInstallation Items Needed Installing Heater Base AssemblyExternal Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Propane/LPNatural Installing Remote Receiver Unit Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Installing Wireless hand- Held Remote control AccessoryInstalling 9-Volt Battery in Receiver Installing Front Log #1 CCL3930PR/NR Shown Installing LogsInstalling Crossover Log #4 CCL3930PR/NR Shown For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance Optional Hand-Held  MANUAL Lighting ProcedureRemote Operation On/Off Series Model HRC101Pilot Flame Pattern Inspecting BurnersBurner Injector Holder and Pilot Air Inlet Hole Cleaning MaintenanceLogs Main burnerObserved Problem Possible Cause Remedy TroubleshootingMaintenance, See Cleaning and Mainte See Checking Gas Connec Gas leak. See WarningModels CCL3018PR, CCL3018PRA, CCL3018NR and CCL3018NRA Illustrated Parts BreakdownParts List Models CCL3930NRA Description QTY Wiring Diagram SpecificationsTechnical Service Service HintsParts Under Warranty Replacement PartsParts Not Under Warranty Parts CentralReceiver and HAND-HELD Remote Control KIT HRC101 Receiver and HAND-HELD Thermostat Remote Control KIT HRC201Equipment Shutoff Valve GA5010 Fireplace Hood111161-01H Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

CHL3924NR specifications

Desa CHL3924NR is an innovative and versatile heating solution designed to meet the demands of modern living. This unit is particularly favored for its combination of efficiency, performance, and advanced technology, making it an ideal choice for homeowners looking for effective heating options.

One of the standout features of the Desa CHL3924NR is its impressive heating capacity. With a powerful design, it can deliver substantial warmth to medium to large spaces while maintaining a user-friendly operation. The unit boasts a range of heating settings, allowing users to customize the temperature according to their preferences and comfort. This flexibility not only enhances user experience but also optimizes energy consumption, contributing to lower utility bills.

Furthermore, the CHL3924NR incorporates cutting-edge technology to ensure reliable and efficient performance. The unit comes with a state-of-the-art digital thermostat that provides precise temperature control. This feature allows for easy monitoring and adjustment, ensuring that a comfortable environment is maintained effortlessly.

Energy efficiency is a hallmark of the Desa CHL3924NR. It is designed to minimize energy waste while maximizing output, making it an environmentally conscious choice. The unit's efficient fuel consumption means it operates with lower emissions compared to traditional heating systems, aligning with the growing trend towards sustainable living.

Durability is another significant characteristic of the Desa CHL3924NR. Constructed with high-quality materials, this heating unit is built to last, and its robust design can withstand the rigors of daily use. Coupled with a sleek, modern aesthetic, it seamlessly integrates into various home décors.

Safety features are paramount in the design of the CHL3924NR, ensuring peace of mind during operation. The unit is equipped with safety shut-off mechanisms, preventing overheating and potential hazards.

In conclusion, the Desa CHL3924NR stands out as a reliable, efficient, and stylish heating solution, perfect for contemporary homes. Its combination of advanced technology, user-friendly features, energy efficiency, and safety make it an excellent choice for anyone looking to enhance their heating experience. Whether for a cozy night in or providing warmth during colder months, the Desa CHL3924NR delivers exceptional performance that meets the needs of today’s consumers.