C-10
Cisco MGX 8220 Installation and Configuration
Release 5.0, Part Number 78-6430-03 Rev. D0, November 2003
Appendix C Firmware Upgrade and Downgrade Procedures
Standard Upgrade and Downgrade Proced ures
Use this step to examine the number of lines, p or t s, an d ch an n els af t er the upgr ad e o r downgr ad e. Th e
values can be compared to those b efor e t h e d own lo ad a nd i t c an be es t ab li she d that the configuration
has remained the same. Restor e t he ASC and SM configurations if ne cess a ry.
Procedure 5Standard Upgrade, 1-Core Card Set
Procedure 5 is used for 1.2.x to 4.y, and 2.3.x to 4.y.
Step 1 Save the current ASC configuration. Perform this step for the ASC prior to upgrading the firmware.
First reset the card, then u se T FTP get to save the cards current configuration in the workstation.
tftp shelf
tftp> bin
tftp> get AXIS_ASC_ACTIVE.BR
Step 2 Save the current service module (SM) co nfiguration for each primary and stand- alone SM. Perform this
step for the SM prior to upgrading the firmware.
First reset the card, then u se T FTP get to save the cards current configuration in the workstation.
tftp shelf
tftp> bin
tftp> get AXIS_SM_1_<slot>.PRI.<service password>
Step 3 Enter the dspadrcxat command. Note the value of th e ConnNumOfValidEntries parameter.
This value indicates the number of connections. This command is run again at the end of the procedure
to ensure that the number of co nnec tions has not changed.
Step 4 For all stand-alone and primary SM s
a. Enter the dsptotals command.
The configuration of the shelf should not be changed during the downgrade process. Use this step
to examine the number of lines, ports, and channels before the upgrade or downgrade. A similar
step can be made to examine the same configuration parameters after the upgrade or downgrade
and, therefore, it can be estab li she d that the configuration has rema ined the same.
b. Enter the tftp put <ASC_BT_fi le> AXIS_A SC_B ACKUP.FW command. This step downloads the
new boot code into the ASC.
c. Enter the chkflash command. This command ca lculates and compares the Flash ch ecksum to verify
whether the boot code is correct.
d. Enter the version command. This command displays the version of the boot code currently stored
in Flash memory. This ste p dow nloads new firmware int o th e ASC.
e. Enter the tftp put <ASC_FW_file> AXIS_ASC_ACTIVE.FW command.
f. Check the file size of the download ed firmw ar e. This step can be used to check t h at th e firm w ar e
was downloaded successfully to th e A S C d i s k.
g. Enter the dspfwrevs command to verify the correct firmware revision.