7-28

Cisco MGX 8220 Installation and Configuration
Release 5.0, Part Number 78-6430-03 Rev. D0, November 2003
Chapter
Making the BNM Trunk Connection
Making the BNM Trunk Connection

Connect two T3 coaxial cables b et w een t he T3 B NC connectors on the MGX 8220 B N M li ne m o du l e

card and the T3 BNC connector s o n th e B PX BNI line module. The trans mit po r t on th e BP X l ine

module and the receive port on the MGX 8220 BNM line module must connect to each other. (See

Figure7-22.)

Figure7-22 Connecting BNM-T3 or BMN-E3 Cables

If redundant BNM cards are being used, use Y-cable adapters as shown in Figure7-23. It is

recommended that specially desig n ed s h ort T3 or E 3 Y-cables be pur ch ase d from Cisco.

•••••••••••••••
T3E3-B
RX
TX
A
L
A
R
M
R
E
L
A
Y
S
E
X
T
T
M
G

T3 Trunk

RCV

XMT

H8294