C-22
Cisco MGX 8220 Installation and Configuration
Release 5.0, Part Number 78-6430-03 Rev. D0, November 2003
Appendix C Firmware Upgrade and Downgrade Procedures
Graceful Upgrade and Downgrade Procedu res
A CWM workstation attached to a BPX is one method in which MGX 8220 commands and TFTP
commands can be run on the MGS 8220 using an inband channe l. The wor ks tat i on can al so be att ach ed
to the MGX 8220 through an Ethernet LAN, or through a TCP/IP connection o n the control port on the
ASC.
Procedure 13Graceful Upgrade, 1-Core Card Set (SM only)
Procedure 13 is use d f o r 1. 2.x to 2.y.
Step 1 Save the current ASC configuration. Perform this step for the ASC prior to upgrading the firmware.
First reset the card, then u se T FTP get to save the cards current configuration in the workstation.
tftp shelf
tftp> bin
tftp> get AXIS_ASC_ACTIVE.BR
Step 2 Save the current service module (SM) co nfiguration for each primary and stand- alone SM. Perform this
step for the SM prior to upgrading the firmware.
First reset the card, then u se T FTP get to save the cards current configuration in the workstation.
tftp shelf
tftp> bin
tftp> get AXIS_SM_1_<slot>.PRI.<service password>
Step 3 Enter the dspadrcxat command. Note the value of th e ConnNumOfValidEntries parameter.
This value indicates the number of connec tion. This command is run again at the end of th e p roce dure
to ensure that the number of co nnec tions has not changed.
Step 4 For all SMs, enter the dsptotals command.
The configuration of the shelf should not be changed during the downgrade process. Use this step to
examine the number of lines, ports, and cha nn el s befo r e th e up g ra de or dow ngr ad e. A sim i lar step can
be made to examine the same configuration par ame ters after the upgrade or downgrade and, therefo r e,
it can be established that the co nfiguration has remained the sa m e.
Step 5 For all SMs
a. Enter the flashStartAddr and flashEndAddr commands to start the Flash memo r y file at
0xbfc00000 and end it at 0xbfc40000.
shelf.1.<slot>.<type><a|s>flashStartAddr = 0xbfc00000
shelf.1.<slot>.<type>.<a|s>flashEndAddr = 0xbfc40000
b. Enter the tftp put <SM_BT_file> AXIS_SM_1_$slot.FW command.
c. Enter the chkflash command. This command ca lculates and compares the Flash ch ecksum to verify
whether the boot code is correct.
d. Enter the version command. This command displays the version of the boot code currently stored
in Flash memory. This ste p dow nloads new firmware int o th e ASC.
Step 6 For all SMs
a. Enter the flashStartAddr and flashEndAddr commands to start the Flash memo r y file at
Oxbfc40000 and end it at 0xbfd00000
shelf.1.<slot>.<type><a|s>flashStartAddr = 0xbfc40000
shelf.1.<slot>.<type>.<a|s>flashEndAddr = 0xbfd00000