Desa CHL3924NR Product Identification, Unpacking, Product Features, Remote Control Accessories

Page 5

Product

Identification

Log Set

Optional

Remote

Control Piezo

Ignitor

 

 

Base

Optional

 

Grate

Selector

Flame

Control

Switch

Adjustment

Knob

 

Knob

 

 

Figure 1 - Vent-Free Gas Log Heater

(Logs May Vary By Model)

Unpacking

CAUTION: Do not remove the dataplatesattachedtotheheater base assembly. The data plates contain important warranty and safety information.

1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base as- sembly by burners. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging applied to logs and heater for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

Product Features

Operation

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic dancing, yellow flames. This heater is designed for vent-free operation with flue damper closed. It has been tested and approved to ANSI Z21.11.2 standard for unvented heaters. This heater may also be operated as a vented decorative (ANSI Z21.60) product by opening flue damper (non-thermostat models only).

Safety Pilot

This heater has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

Piezo Ignition System

This heater has a piezo ignitor. This system re- quires no matches, batteries or other sources to light heater.

Remote Control

Accessories

There are two optional remote controls that can be purchased separately for this log heater:

hand-held ON/OFF remote

hand-held thermostat remote

See Accessories, page 34.

The hand-held thermostat may not be used where vented decorative listing is required.

Air For Combustion

and Ventilation

WARNING: This heater shall not be installed in a confined space or unusually tight con- struction unless provisions are provided for adequate combus- tion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy effi- cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

111161-01Hwww.desatech.com

Image 5
Contents Yellow Flame Model Shown 18, 24 and 30 Remote ReadySafety Information Table of ContentsSafety Information Local Codes Remote Control Accessories Product FeaturesProduct Identification UnpackingDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationVent-Free Operation Only Installation and ClearancesMinimum Fireplace Clearance To Combustible Materials Minimum FireboxMantel Clearances If Using MantelFloor Clearances Installing Damper Clamp Accessory for Vented OperationChimney Minimum Permanent 15 toInstallation Items Needed Installing Heater Base AssemblyExternal Regulator With Vent Pointing Down Connecting to GAS SupplyNatural Checking GAS ConnectionsPropane/LP Test Pressures Equal To or Less Than Psig 3.5 kPa Installing Remote Receiver UnitPressure Testing Heater Gas Connections Installing 9-Volt Battery in Receiver Installing Wireless hand- Held Remote controlAccessory Installing Front Log #1 CCL3930PR/NR Shown Installing LogsInstalling Crossover Log #4 CCL3930PR/NR Shown Lighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To Appliance Optional Hand-Held  MANUAL Lighting ProcedureRemote Operation On/Off Series Model HRC101Pilot Flame Pattern Inspecting BurnersBurner Injector Holder and Pilot Air Inlet Hole Cleaning MaintenanceLogs Main burnerObserved Problem Possible Cause Remedy TroubleshootingMaintenance, See Cleaning and Mainte See Checking Gas Connec Gas leak. See WarningModels CCL3018PR, CCL3018PRA, CCL3018NR and CCL3018NRA Illustrated Parts BreakdownParts List Models CCL3930NRA Description QTY Wiring Diagram SpecificationsTechnical Service Service HintsParts Under Warranty Replacement PartsParts Not Under Warranty Parts CentralReceiver and HAND-HELD Remote Control KIT HRC101 Receiver and HAND-HELD Thermostat Remote Control KIT HRC201Equipment Shutoff Valve GA5010 Fireplace Hood111161-01H Limited Warranty VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

CHL3924NR specifications

Desa CHL3924NR is an innovative and versatile heating solution designed to meet the demands of modern living. This unit is particularly favored for its combination of efficiency, performance, and advanced technology, making it an ideal choice for homeowners looking for effective heating options.

One of the standout features of the Desa CHL3924NR is its impressive heating capacity. With a powerful design, it can deliver substantial warmth to medium to large spaces while maintaining a user-friendly operation. The unit boasts a range of heating settings, allowing users to customize the temperature according to their preferences and comfort. This flexibility not only enhances user experience but also optimizes energy consumption, contributing to lower utility bills.

Furthermore, the CHL3924NR incorporates cutting-edge technology to ensure reliable and efficient performance. The unit comes with a state-of-the-art digital thermostat that provides precise temperature control. This feature allows for easy monitoring and adjustment, ensuring that a comfortable environment is maintained effortlessly.

Energy efficiency is a hallmark of the Desa CHL3924NR. It is designed to minimize energy waste while maximizing output, making it an environmentally conscious choice. The unit's efficient fuel consumption means it operates with lower emissions compared to traditional heating systems, aligning with the growing trend towards sustainable living.

Durability is another significant characteristic of the Desa CHL3924NR. Constructed with high-quality materials, this heating unit is built to last, and its robust design can withstand the rigors of daily use. Coupled with a sleek, modern aesthetic, it seamlessly integrates into various home décors.

Safety features are paramount in the design of the CHL3924NR, ensuring peace of mind during operation. The unit is equipped with safety shut-off mechanisms, preventing overheating and potential hazards.

In conclusion, the Desa CHL3924NR stands out as a reliable, efficient, and stylish heating solution, perfect for contemporary homes. Its combination of advanced technology, user-friendly features, energy efficiency, and safety make it an excellent choice for anyone looking to enhance their heating experience. Whether for a cozy night in or providing warmth during colder months, the Desa CHL3924NR delivers exceptional performance that meets the needs of today’s consumers.