Desa LGCFTN Operating Fireplace, To Turn OFF GAS To Appliance, Thermostat Control Operation

Page 19

OPERATING FIREPLACE

Continued

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, page 22. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety in- terlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor

Pilot Burner

Electrode

Thermocouple

Figure 28 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1. Turn control knob clockwise to the OFF position.

2. Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PI- LOT position.

THERMOSTAT

CONTROL OPERATION

The thermostatic control used on this fireplace differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this fireplace senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the heater will cycle back on when room tem- perature drops below the set temperature.

The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb measures the temperature of air near the fireplace cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, open air temperatures, etc.). Frequent use of your fireplace will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 18.

2.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, column 1.

119508-01A

www.desatech.com

19

Image 19
Contents Lgcftp and Lgcftn Shown with Optional Cabinet Mantel/Hearth Base Accessory14,000 to 26,000 Btu/Hr with Thermostat Safety Information Table of ContentsSafety Information Product Information Local CodesProvide adequate clearances around air openings Assembly Product FeaturesUnpacking Providing Adequate Ventilation AssemblyAssembling and Installing Trim Air For Combustion VentilationConfined and Unconfined Space Determining FRESH-AIR Flow for fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors InstallationVentilation AIR Ventilation Air From Inside BuildingCheck GAS Type Installation ItemsLocating Fireplace Fireplace pilot and burner must be at least 18 above floor Built-In Fireplace InstallationCheck all gas connections for leaks. See If you have not assembled firebox, follow instructions onChecking Gas Connections, Removing Upper Louver Assembly Mantel Clearances for Built- In InstallationOptional Mantel Installation Installing blower accessory GA3450TACan cause improper and danger Installing Blower AssemblyExtension Cord Connecting to GAS SupplyFor Built-In Installation Reinstall valve cover shieldNatura L Accessories,Checking Gas Connections Connecting Equipment shutoff valve to heater controlInstallation Items Needed Checking GAS ConnectionsCorrect all leaks at once Pressure Testing Fireplace Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Operating Fireplace For Your Safety Read Before LightingLighting Instructions Thermostat Control Operation Manual Lighting ProcedureOperating Fireplace To Turn OFF GAS To ApplianceBurner Flame Pattern Cleaning MaintenanceInspecting Burner Pilot Flame PatternAir Passageways CabinetExterior Observed Problem Possible Cause Remedy TroubleshootingMaintenance TroubleshootingMaintenance, See Cleaning and MainteSee Checking Gas Connec Gas leak. See WarningReplacement Parts SpecificationsService Hints Technical ServiceTHERMOSTATICALLY-CONTROLLED Blower KIT GA3450TA AccessoriesEquipment Shutoff Valve GA5010 Brass Trim KIT GA6095Models Lgcftp and Lgcftn Illustrated Parts BreakdownParts List Parts Centrals 119508-01A VENT-FREE Compact fireplace Warranty InformationKeep this Warranty Limited Warranty

LGCFTN, LGCFTP specifications

Desa LGCFTP and LGCFTN are innovative technology solutions designed to cater to modern communication and data management needs. These platforms are part of a broader suite of services aimed at enhancing connectivity, streamlining data flow, and enabling seamless interaction between users and systems.

One of the main features of Desa LGCFTP is its robust file transfer capabilities. It utilizes the File Transfer Protocol (FTP) to ensure that data can be moved securely and efficiently over networks. This feature is particularly crucial for businesses that handle large amounts of data, as it allows for the quick transfer of files ranging from reports to multimedia content without compromising on security.

In addition to the FTP functionalities, Desa LGCFTN incorporates advanced networking technologies that enhance connectivity among users. This platform is designed to facilitate reliable connectivity options, enabling organizations to establish networks that can support various applications, from simple database queries to complex real-time data exchanges.

Both Desa LGCFTP and LGCFTN are built with scalability in mind. This means that as user requirements grow, these systems can easily adapt to accommodate increased data loads and more extensive user bases. The technology underpinning these platforms is based on an architecture that supports distributed processing, which is essential for ensuring that performance remains high, even as demand fluctuates.

Security is a top priority for both platforms. They implement a range of protocols and encryption techniques to safeguard data during transfers and while at rest. This commitment to security helps organizations maintain compliance with industry standards and regulations, which is increasingly important in today’s data-driven environment.

Desa LGCFTP and LGCFTN also emphasize user experience. Their intuitive interfaces make it easy for users to manage files and navigate through different features. This focus on usability reduces the learning curve, ensuring that teams can quickly leverage the full capabilities of the platforms without extensive training.

In summary, Desa LGCFTP and LGCFTN represent cutting-edge solutions in the realm of file transfer and network connectivity. With their emphasis on security, scalability, and user experience, these platforms are well-equipped to meet the challenges faced by modern businesses, making them invaluable tools for efficient data management and communication.