Desa LGCFTN, LGCFTP installation manual Product Features, Unpacking, Assembly

Page 5

Product Features

Safety Pilot

This fireplace has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.

Piezo Ignition System

This fireplace has a piezo ignitor. This system requires no matches, batteries or other sources to light fireplace.

Thermostatic Heat Control

This fireplace has a thermostat sensing bulb and a control valve. The thermostat will automatically modulate the heat output to maintain a consistent room temperature. This results in greater fireplace comfort. This can also result in lower gas bills.

Unpacking

1.Remove fireplace from carton.

2.Remove all protective packaging applied to fireplace for shipment.

3.Make sure your fireplace includes one hard- ware packet.

4.Check fireplace for any shipping damage. If fireplace is damaged, promptly inform dealer where you bought fireplace.

Assembly

WARNING: Always have branch support and screen in place before operating fireplace. This prevents excessive temper- atures on fireplace surfaces.

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in prop- erty damage or personal injury.

Assembling Fireplace

Tools Required:

 

 

Phillips screwdriver

slotted screwdriver

5/16" hex wrench

scissors

Installing Log

1. Lift screen up and pull out to remove.

2.Cut two plastic straps to remove the log from the firebox cavity.

3.An optional blower is available. See Accessories, page 27. Install optional blower now. Follow installation instructions provided with blower.

4.Remove log packaging material and discard packaging. Gently place log set on burner support (see Figure 2). The log should fit flat against top of burner support and log locator tabs fit into the slots under the log. Do not allow log to contact flame. If flame contacts log, soot will be created.

5.Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down.

 

 

 

 

Shoulder

Burner Support with

Log

Screw

Log Locator Tabs

 

 

 

Branch

Support

Screen

Figure 2 - Assembling Fireplace

Assembling Hood

1. Locate four black phillips sheet metal screws from the hardware packet.

2. Insert hood between firebox top and louvers (see Figure 3).

3. Align screw holes on hood with screw holes on firebox top.

4. Insert screws as shown in Figure 3. Tighten screws firmly.

Firebox

Top Hood

Sheet Metal

Screws

Figure 3 - Assembling Hood

119508-01Awww.desatech.com

Image 5 Contents
14,000 to 26,000 Btu/Hr with Thermostat Shown with Optional Cabinet Mantel/Hearth Base Accessory Lgcftp and Lgcftn Safety Information Table of ContentsSafety Information Provide adequate clearances around air openings Local CodesProduct Information Unpacking Product FeaturesAssembly Assembling and Installing Trim AssemblyAir For Combustion Ventilation Providing Adequate VentilationDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for fireplace LocationConfined and Unconfined Space Ventilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsLocating Fireplace Installation ItemsCheck GAS Type Fireplace pilot and burner must be at least 18 above floor Built-In Fireplace InstallationChecking Gas Connections, If you have not assembled firebox, follow instructions onCheck all gas connections for leaks. See Optional Mantel Installation Mantel Clearances for Built- In InstallationInstalling blower accessory GA3450TA Removing Upper Louver AssemblyCan cause improper and danger Installing Blower AssemblyFor Built-In Installation Connecting to GAS SupplyReinstall valve cover shield Extension CordNatura L Accessories,Installation Items Needed Connecting Equipment shutoff valve to heater controlChecking GAS Connections Checking Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsCorrect all leaks at once Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Operating Fireplace Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationInspecting Burner Cleaning MaintenancePilot Flame Pattern Burner Flame PatternExterior CabinetAir Passageways Observed Problem Possible Cause Remedy TroubleshootingMaintenance TroubleshootingMaintenance, See Cleaning and MainteSee Checking Gas Connec Gas leak. See WarningService Hints SpecificationsTechnical Service Replacement PartsEquipment Shutoff Valve GA5010 AccessoriesBrass Trim KIT GA6095 THERMOSTATICALLY-CONTROLLED Blower KIT GA3450TAModels Lgcftp and Lgcftn Illustrated Parts BreakdownParts List Parts Centrals 119508-01A Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact fireplace