Desa VMH26PR Connecting to GAS Supply, Extension Cord, Attaching Wood Base to Solid Floor

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

Extension Cord

Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An undersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

Attaching Wood Base to Solid Floor

For attaching base to solid floors (concrete or masonry)

Note: Floor anchors and mounting screws are in hardware package. The hardware pack- age is provided with fireplace.

1.

Drill holes at marked locations using

 

5/16" drill bit. For solid floors (concrete

 

or masonry), drill at least 1" deep.

2.

Fold floor anchor as shown in Figure 21.

3.

Insert floor anchor (wings first) into

 

hole. Tap anchor flush to floor.

4.

Insert mounting screws through base

 

and into floor anchors.

5.

Tighten screws until base is firmly fas-

 

tened to floor.

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regu- lator with the vent pointing down as shown in Figure 22. Pointing the vent down pro- tects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" or greater diameter to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur.

External Regulator

Propane/LP

Supply Tank

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 23).

IMPORTANT: Install main gas valve (manual shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 23. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

Figure 21 - Folding Anchor

CONNECTING TO GAS SUPPLY

WARNING: A qualified ser- vice person must connect fire- place to gas supply. Follow all local codes.

CAUTION: Never connect fire- place directly to the propane/LP supply. This fireplace requires an external regulator (not sup- plied). Install the external regula- tor between the fireplace and pro- pane/LP supply.

Vent Pointing Down

Figure 22 - External Regulator with Vent

Pointing Down

From External

A.G.A. Design-Certified Manual

Shutoff Valve with 1/8" NPT Tap*

Regulator

 

(11" W.C.** to

 

14" W.C.

Approved Flexible

Pressure)

Gas Hose

 

 

Gas Control

Tee Joint

 

Pipe

 

Nipple

3" Minimum

Cap

Sediment Trap

Figure 23 - Gas Connection

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, pages 26 and 27.

**Minimum inlet pressure for purpose of input adjustment.

Continued

104323

13

Image 13
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GASCompact Classic Hearth Fireplace Safety InformationRemote Control Accessories Product FeaturesProduct Identification Local CodesInstalling Log AssemblyAssembling Fireplace Assembling HoodProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating FireplaceRough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationAssembling Brass Trim Brass trim shipped with mantel Removing Upper Louver Assembly Installing Blower Accessory GA3400TInstalling Blower Assembly Test to make sure the blower is work- ing properly For Built-In InstallationExtension Cord Connecting to GAS SupplyAttaching Wood Base to Solid Floor Installation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Installing Receiver Optional Wireless HAND- Held Remote Control AccessoriesInstalling 9-Volt Battery in Hand- Held Remote Control Unit Optional Wall Mounted Thermostat GWMT1Route the 25 ft. wire to a convenient Optional Wall Switch GWMS2Operating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation OPERATINGGWMT1 Wall Fireplace GWMS2 Wall Mounted Switch OptionalOptional Operating BlowerPilot Flame Pattern Inspecting BurnersBurner Flame Pattern Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Service Hints Cleaning and MaintenanceTechnical Service Wiring DiagramAccessories Replacement Parts SpecificationsVMH26PR4 Illustrated Parts BreakdownVMH26PR Parts ListInternational Warranty Information

VMH26PR specifications

Desa VMH26PR is a cutting-edge horizontal multistage pump designed for a variety of applications, primarily in industrial and municipal sectors. Its robust construction delivers excellent performance and reliability, making it a preferred choice for demanding environments.

One of the primary features of the VMH26PR is its versatile design. Engineered for efficiency, it is capable of handling a wide range of fluids, including clean water, chemicals, and other industrial liquids. This pump is particularly known for its ability to operate under high-pressure conditions while maintaining a low energy consumption rate, which is a significant advantage in terms of operational costs.

The VMH26PR incorporates advanced hydraulic technologies, which enhance both performance and efficiency. The multistage configuration allows for higher pressure generation, making it ideal for applications that require elevated discharge pressures. Each stage is meticulously designed to optimize flow, reducing turbulence and maximizing throughput. This results in improved overall system efficiency and longevity of the pump.

In terms of materials, the VMH26PR offers various casing options tailored to the specific needs of the application, including stainless steel and cast iron. These materials provide excellent resistance to corrosion and wear, ensuring durability even in harsh environments. Additionally, the pump features mechanical seals designed to minimize leakage and enhance reliability.

Another significant technological aspect of the VMH26PR is its modular design. This allows for easy maintenance and component replacement, reducing downtime and service costs. Users can easily access vital parts without disassembling the entire unit, which is a considerable advantage for operation in critical settings.

Moreover, the Desa VMH26PR is equipped with a range of monitoring and control options, enabling seamless integration into automated processes. This feature enhances operational efficiency, allowing operators to monitor performance parameters in real-time and make data-driven decisions to optimize performance.

Overall, the Desa VMH26PR stands out with its combination of efficiency, durability, and ease of maintenance, making it an ideal solution for various fluid handling tasks across different industries. Its ability to adapt to specific requirements and conditions ensures it will meet the diverse needs of modern applications effectively.