Desa VMH26PR Installing Blower Accessory GA3400T, Removing Upper Louver Assembly

Page 11

OWNER’S MANUAL

INSTALLATION

Continued

INSTALLING BLOWER ACCESSORY GA3400T

Removing Upper Louver

Assembly

To install the blower accessory, you must first remove the upper louver assembly.

1.

Lift screen off heater and remove log set.

2.

Remove 2 screws from each side of

 

branch support and pull branch support

 

out (see Figure 15).

3.

Remove 4 brass-plated screws from

 

louver assembly (see Figure 15). Save

 

these screws.

4.

Pull louver assembly straight out from

 

the cabinet. Be careful not to scratch

 

the paint. Set louver assembly and

Installing Blower Assembly

Note: If you are using a mantel with your heater, use the following instructions. If your heater is built-in, see For Built-In In- stallation on page 12.

1.Install snap bushings found in hardware kit into both holes in rear of valve cover shield.

2.Make sure the wire harness is firmly connected to the terminals on the blower bracket assembly.

3.Note the wire locations on back of AUTO/OFF/ON switch. The terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 3 and blue wire from termi- nal 1. Black wire can remain on middle terminal 2 (see figure 16).

4.Carefully disconnect green and white wires at their insulated connectors.

5.In top of the heater cabinet, locate the four mounting holes on the outer cas- ing. Align these four holes with those on the blower bracket assembly. Attach blower bracket assembly to the outer casing with 4 #10 screws provided (see Figure 16).

6.Route the wire harness through the hole in left side of baffle. Pull wire harness through lower opening on the side of the valve shield. (see Figure 16).

7.Insert the 4 wire harness into one of the round holes in the rear of the valve cover shield and through the rectangular hole in the front of shield (see figure 16).

8.Reconnect red wire to switch position 3. Reconnect blue wire to switch posi- tion 1. Reconnect green and white wires.

screws aside.

Blower Bracket

Mounting Holes

Upper Louver

Assembly

Branch Support

Figure 15 - Removing Upper Louver Assembly and Branch Support

 

Wire

Wiring Routing

Blower Bracket

Hole in Baffle

Harness

 

Assembly

 

 

Baffle

Screw

 

 

 

Switch

Power

 

 

Cord

Snap

 

 

 

 

Bushing

 

3

 

 

2

 

 

1

 

Red

Blue

Switch

Plate

Wire

Harness

Valve Cover

Shield

Figure 16 - Installing Blower Bracket Assembly

Continued

104323

11

Image 11
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GASCompact Classic Hearth Fireplace Safety InformationLocal Codes Product FeaturesRemote Control Accessories Product IdentificationAssembling Hood AssemblyInstalling Log Assembling FireplaceConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locating Fireplace InstallationInstallation Items Check GAS TypeRough Opening for Installing in Wall BUILT-IN Fireplace InstallationAssembling Brass Trim Brass trim shipped with mantel Optional Mantel InstallationMantel Clearances for Built-In Installation Installing Blower Assembly Installing Blower Accessory GA3400TRemoving Upper Louver Assembly Test to make sure the blower is work- ing properly For Built-In InstallationAttaching Wood Base to Solid Floor Connecting to GAS SupplyExtension Cord Installation Items Needed Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Fireplace Gas ConnectionsPressure Testing Gas Supply Piping System Optional Wall Mounted Thermostat GWMT1 Optional Wireless HAND- Held Remote Control AccessoriesInstalling Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitRoute the 25 ft. wire to a convenient Optional Wall Switch GWMS2Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Operating Blower GWMS2 Wall Mounted Switch OptionalOPERATINGGWMT1 Wall Fireplace OptionalBurner Flame Pattern Inspecting BurnersPilot Flame Pattern Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Wiring Diagram Cleaning and MaintenanceService Hints Technical ServiceAccessories Replacement Parts SpecificationsVMH26PR4 Illustrated Parts BreakdownVMH26PR Parts ListInternational Warranty Information

VMH26PR specifications

Desa VMH26PR is a cutting-edge horizontal multistage pump designed for a variety of applications, primarily in industrial and municipal sectors. Its robust construction delivers excellent performance and reliability, making it a preferred choice for demanding environments.

One of the primary features of the VMH26PR is its versatile design. Engineered for efficiency, it is capable of handling a wide range of fluids, including clean water, chemicals, and other industrial liquids. This pump is particularly known for its ability to operate under high-pressure conditions while maintaining a low energy consumption rate, which is a significant advantage in terms of operational costs.

The VMH26PR incorporates advanced hydraulic technologies, which enhance both performance and efficiency. The multistage configuration allows for higher pressure generation, making it ideal for applications that require elevated discharge pressures. Each stage is meticulously designed to optimize flow, reducing turbulence and maximizing throughput. This results in improved overall system efficiency and longevity of the pump.

In terms of materials, the VMH26PR offers various casing options tailored to the specific needs of the application, including stainless steel and cast iron. These materials provide excellent resistance to corrosion and wear, ensuring durability even in harsh environments. Additionally, the pump features mechanical seals designed to minimize leakage and enhance reliability.

Another significant technological aspect of the VMH26PR is its modular design. This allows for easy maintenance and component replacement, reducing downtime and service costs. Users can easily access vital parts without disassembling the entire unit, which is a considerable advantage for operation in critical settings.

Moreover, the Desa VMH26PR is equipped with a range of monitoring and control options, enabling seamless integration into automated processes. This feature enhances operational efficiency, allowing operators to monitor performance parameters in real-time and make data-driven decisions to optimize performance.

Overall, the Desa VMH26PR stands out with its combination of efficiency, durability, and ease of maintenance, making it an ideal solution for various fluid handling tasks across different industries. Its ability to adapt to specific requirements and conditions ensures it will meet the diverse needs of modern applications effectively.