Desa VMH26PR installation manual Compact Classic Hearth Fireplace, Safety Information

Page 2

® VMH26PR

COMPACT CLASSIC HEARTH FIREPLACE

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this fireplace. Im- proper use of this fireplace can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the fire- place may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include preg- nant women, people with heart or lung dis- ease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to pro- pane/LP gas. The odor helps you detect a propane/LP gas leak. However, the odor added to propane/LP gas can fade. Propane/LP gas may be present even though no odor exists.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this fireplace or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bedroom or bathroom.

5.Never install the fireplace

in a recreational vehicle.

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the fireplace.

as a fireplace insert.

in high traffic areas.

in windy or drafty areas.

6.Do not use this fireplace as a wood- burning fireplace. Use only the logs provided with the fireplace.

7.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

8.You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is in place before run- ning fireplace.

9.This fireplace is designed to be smoke- less. If logs ever appear to smoke, turn off fireplace and call a qualified ser- vice person. Note: During initial op- eration, slight smoking could occur due to log curing and fireplace burning manufacturing residues.

10.To prevent the creation of soot, follow the instructions in Cleaning and Main- tenance, page 25.

11.Do not allow fans to blow directly into the fireplace. Avoid any drafts that al- ter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

12.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from

these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

13.This fireplace needs fresh air ventila- tion to run properly. This fireplace has an oxygen depletion sensor (ODS) pi- lot light safety system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 7. If fireplace keeps shutting off, see Troubleshooting, pages 22 through 24.

14.Do not run fireplace

where flammable liquids or vapors are used or stored.

under dusty conditions.

15.Do not use this fireplace to cook food or burn paper or other objects.

16.Never place any objects in the fireplace or on logs.

17.Fireplace front and screen becomes very hot when running fireplace. Keep children and adults away from hot sur- faces to avoid burns or clothing igni- tion. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.

18.Carefully supervise young children when they are in same room with fire- place.

19.Do not use fireplace if any part has been under water. Immediately call a quali- fied service technician to inspect the room fireplace and to replace any part of the control system and any gas con- trol which has been under water.

20.Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and re- pair fireplace.

21.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

22.Do not use a blower insert, heat ex- changer insert, or other accessory not approved for use with this fireplace.

23.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

24.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

2

104323

Image 2
Contents VENT-FREE PROPANE/LP GAS What to do if YOU Smell GASSafety Information Compact Classic Hearth FireplaceProduct Identification Product FeaturesRemote Control Accessories Local CodesAssembling Fireplace AssemblyInstalling Log Assembling HoodUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Locating FireplaceBUILT-IN Fireplace Installation Rough Opening for Installing in WallAssembling Brass Trim Brass trim shipped with mantel Optional Mantel InstallationMantel Clearances for Built-In Installation Installing Blower Assembly Installing Blower Accessory GA3400TRemoving Upper Louver Assembly For Built-In Installation Test to make sure the blower is work- ing properlyAttaching Wood Base to Solid Floor Connecting to GAS SupplyExtension Cord Connecting Fireplace to GAS Supply Installation Items NeededChecking GAS Connections Pressure Testing Fireplace Gas ConnectionsPressure Testing Gas Supply Piping System Installing 9-Volt Battery in Hand- Held Remote Control Unit Optional Wireless HAND- Held Remote Control AccessoriesInstalling Receiver Optional Wall Mounted Thermostat GWMT1Optional Wall Switch GWMS2 Route the 25 ft. wire to a convenientLighting Instructions For Your Safety Read Before LightingOperating Fireplace Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional GWMS2 Wall Mounted Switch OptionalOPERATINGGWMT1 Wall Fireplace Operating BlowerBurner Flame Pattern Inspecting BurnersPilot Flame Pattern Troubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Technical Service Cleaning and MaintenanceService Hints Wiring DiagramAccessories Specifications Replacement PartsIllustrated Parts Breakdown VMH26PR4Parts List VMH26PRWarranty Information International

VMH26PR specifications

Desa VMH26PR is a cutting-edge horizontal multistage pump designed for a variety of applications, primarily in industrial and municipal sectors. Its robust construction delivers excellent performance and reliability, making it a preferred choice for demanding environments.

One of the primary features of the VMH26PR is its versatile design. Engineered for efficiency, it is capable of handling a wide range of fluids, including clean water, chemicals, and other industrial liquids. This pump is particularly known for its ability to operate under high-pressure conditions while maintaining a low energy consumption rate, which is a significant advantage in terms of operational costs.

The VMH26PR incorporates advanced hydraulic technologies, which enhance both performance and efficiency. The multistage configuration allows for higher pressure generation, making it ideal for applications that require elevated discharge pressures. Each stage is meticulously designed to optimize flow, reducing turbulence and maximizing throughput. This results in improved overall system efficiency and longevity of the pump.

In terms of materials, the VMH26PR offers various casing options tailored to the specific needs of the application, including stainless steel and cast iron. These materials provide excellent resistance to corrosion and wear, ensuring durability even in harsh environments. Additionally, the pump features mechanical seals designed to minimize leakage and enhance reliability.

Another significant technological aspect of the VMH26PR is its modular design. This allows for easy maintenance and component replacement, reducing downtime and service costs. Users can easily access vital parts without disassembling the entire unit, which is a considerable advantage for operation in critical settings.

Moreover, the Desa VMH26PR is equipped with a range of monitoring and control options, enabling seamless integration into automated processes. This feature enhances operational efficiency, allowing operators to monitor performance parameters in real-time and make data-driven decisions to optimize performance.

Overall, the Desa VMH26PR stands out with its combination of efficiency, durability, and ease of maintenance, making it an ideal solution for various fluid handling tasks across different industries. Its ability to adapt to specific requirements and conditions ensures it will meet the diverse needs of modern applications effectively.