Desa VMH26PR Optional Wireless HAND- Held Remote Control Accessories, Installing Receiver

Page 16

® VMH26PR

COMPACT CLASSIC HEARTH FIREPLACE

INSTALLATION

Continued

OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL ACCESSORIES

(GHRC Series & GHRCT Series)

Installing Receiver

1.Remove screws.

2.Disconnect switch wires from the con- trol valve.

3.Remove switch plate (see Figure 28). Discard switch plate after removing. Save the screws.

4.Locate the battery clip mounted on the back of the receiver (see Figure 29).

5.Slide 9-volt battery (not included) through the clip.

6.Attach the terminal wires to the battery (see Figure 29).

7.Connect wires as shown in Figure 30.

8.Install remote receiver unit onto gas heater base using the two screws re- moved in step one (see Figure 30).

Screw

Switch Plate

Red Wire

Black Wire

Heater Base

Figure 28 - Switch Plate and Wiring Harness

Receiver

Terminal

Wires

Battery Clip

9-Volt Battery

Figure 29 - Attaching Battery to Receiver

 

Remote

 

Receiver

Black Wire

Red Wire

 

Wire Harness*

 

Wires from

Valve

Black Wire

Red Wire

Figure 30 - Installing Remote Receiver

*Wire harness provided in the fireplace hardware pack.

Installing 9-Volt Battery in Hand- Held Remote Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to the battery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Terminal

Battery

Remote

Control Unit

Cover

Wires

 

 

 

9-Volt

 

 

Battery

 

 

 

 

Battery

 

 

Housing

Figure 31 - Installing Battery in Hand- Held Remote Control Unit

OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

WARNING: Read and follow installation instructions. Instal- lation should be done by a quali- fied installer familiar with low- voltage wiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Connect one terminal of 25 ft. wire to bottom contact of switch (see Figure 32, page 17).

2.Connect remaining wire terminal to the “TH” terminal on the control valve. Make sure that wire terminals are in the positions on your unit as pictured in Figure 32 on page 17. If wires are not “crossed” the thermostat will not work.

3.Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall). IMPORTANT: The wire may be shortened but must not be lengthened.

The thermostat should be mounted 54" above the floor in a location where there is good air circulation.Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air conditioning ducts.

4.Gently remove the cover of the ther- mostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.

5.Feed the electrical wires through the rectangular slots on each side of the base (see Figure 33, page 17).

WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire haz- ard will occur.

16

104323

Image 16
Contents VENT-FREE PROPANE/LP GAS What to do if YOU Smell GASSafety Information Compact Classic Hearth FireplaceProduct Features Remote Control AccessoriesProduct Identification Local CodesAssembly Installing LogAssembling Fireplace Assembling HoodAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installation ItemsCheck GAS Type Locating FireplaceBUILT-IN Fireplace Installation Rough Opening for Installing in WallMantel Clearances for Built-In Installation Optional Mantel InstallationAssembling Brass Trim Brass trim shipped with mantel Removing Upper Louver Assembly Installing Blower Accessory GA3400TInstalling Blower Assembly For Built-In Installation Test to make sure the blower is work- ing properlyExtension Cord Connecting to GAS SupplyAttaching Wood Base to Solid Floor Connecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Optional Wireless HAND- Held Remote Control Accessories Installing ReceiverInstalling 9-Volt Battery in Hand- Held Remote Control Unit Optional Wall Mounted Thermostat GWMT1Optional Wall Switch GWMS2 Route the 25 ft. wire to a convenientOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation GWMS2 Wall Mounted Switch Optional OPERATINGGWMT1 Wall FireplaceOptional Operating BlowerPilot Flame Pattern Inspecting BurnersBurner Flame Pattern Troubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Cleaning and Maintenance Service HintsTechnical Service Wiring DiagramAccessories Specifications Replacement PartsIllustrated Parts Breakdown VMH26PR4Parts List VMH26PRWarranty Information International

VMH26PR specifications

Desa VMH26PR is a cutting-edge horizontal multistage pump designed for a variety of applications, primarily in industrial and municipal sectors. Its robust construction delivers excellent performance and reliability, making it a preferred choice for demanding environments.

One of the primary features of the VMH26PR is its versatile design. Engineered for efficiency, it is capable of handling a wide range of fluids, including clean water, chemicals, and other industrial liquids. This pump is particularly known for its ability to operate under high-pressure conditions while maintaining a low energy consumption rate, which is a significant advantage in terms of operational costs.

The VMH26PR incorporates advanced hydraulic technologies, which enhance both performance and efficiency. The multistage configuration allows for higher pressure generation, making it ideal for applications that require elevated discharge pressures. Each stage is meticulously designed to optimize flow, reducing turbulence and maximizing throughput. This results in improved overall system efficiency and longevity of the pump.

In terms of materials, the VMH26PR offers various casing options tailored to the specific needs of the application, including stainless steel and cast iron. These materials provide excellent resistance to corrosion and wear, ensuring durability even in harsh environments. Additionally, the pump features mechanical seals designed to minimize leakage and enhance reliability.

Another significant technological aspect of the VMH26PR is its modular design. This allows for easy maintenance and component replacement, reducing downtime and service costs. Users can easily access vital parts without disassembling the entire unit, which is a considerable advantage for operation in critical settings.

Moreover, the Desa VMH26PR is equipped with a range of monitoring and control options, enabling seamless integration into automated processes. This feature enhances operational efficiency, allowing operators to monitor performance parameters in real-time and make data-driven decisions to optimize performance.

Overall, the Desa VMH26PR stands out with its combination of efficiency, durability, and ease of maintenance, making it an ideal solution for various fluid handling tasks across different industries. Its ability to adapt to specific requirements and conditions ensures it will meet the diverse needs of modern applications effectively.