Desa VMH26PR installation manual Specifications, Replacement Parts

Page 27

OWNER’S MANUAL

ACCESSORIES

Continued

 

HI

MAN

TEMP

AUTO

LO

ON

 

 

OFF

STATUS

 

RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT

GHRCT SERIES

For all models. Allows the gas log heater to be operated in a manually or thermostati- cally controlled mode. You can turn the gas log heater on and off without ever leaving the comfort of your easy chair.

RECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC SERIES

For all models. Allows the gas log heater to be turned on and off by using a hand-held remote control.

WALL MOUNTED THERMOSTAT KIT - GWMT1

(Not Shown)

For all models. Allows easy wall access to the operation of your gas log heater. This will allow you to thermostatically control your heater with the convenience of a wall switch.

WALL MOUNTED SWITCH KIT - GWMS2

(Not Shown)

For all models. Allows convenient access to the operation of your gas log heater.

SPECIFICATIONS

Btu (Variable)

15,000/26,000

Type Gas

Propane/LP Only

Ignition

Piezo

Manifold Pressure

8" W.C.

Inlet Gas Pressure (in. of water) *

 

Maximum

14"

Minimum

11"

Dimensions, Inches (H x W x D)

 

Fireplace (including hood and screws)

25 7/8 x 26 13/16 x 9 3/8

Carton

32 5/8 x 27 3/16 x 11 5/8

Weight, pounds

 

Fireplace

44 1/2 lbs.

Shipping

48 lbs.

* For purposes of input adjustment

 

REPLACEMENT

PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Technical Service Department at 1-800-323-5190 for referral information.

When calling DESA International, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Parts De- partment at 1-800-972-7879 for referral in- formation.

When calling DESA International, have ready

model number of your fireplace

the replacement part number

104323

27

Image 27
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GASCompact Classic Hearth Fireplace Safety InformationLocal Codes Product FeaturesRemote Control Accessories Product IdentificationAssembling Hood AssemblyInstalling Log Assembling FireplaceConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Locating Fireplace InstallationInstallation Items Check GAS TypeRough Opening for Installing in Wall BUILT-IN Fireplace InstallationOptional Mantel Installation Mantel Clearances for Built-In InstallationAssembling Brass Trim Brass trim shipped with mantel Installing Blower Accessory GA3400T Removing Upper Louver AssemblyInstalling Blower Assembly Test to make sure the blower is work- ing properly For Built-In InstallationConnecting to GAS Supply Extension CordAttaching Wood Base to Solid Floor Installation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Optional Wall Mounted Thermostat GWMT1 Optional Wireless HAND- Held Remote Control AccessoriesInstalling Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitRoute the 25 ft. wire to a convenient Optional Wall Switch GWMS2For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation Operating Blower GWMS2 Wall Mounted Switch OptionalOPERATINGGWMT1 Wall Fireplace OptionalInspecting Burners Pilot Flame PatternBurner Flame Pattern Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Wiring Diagram Cleaning and MaintenanceService Hints Technical ServiceAccessories Replacement Parts SpecificationsVMH26PR4 Illustrated Parts BreakdownVMH26PR Parts ListInternational Warranty Information

VMH26PR specifications

Desa VMH26PR is a cutting-edge horizontal multistage pump designed for a variety of applications, primarily in industrial and municipal sectors. Its robust construction delivers excellent performance and reliability, making it a preferred choice for demanding environments.

One of the primary features of the VMH26PR is its versatile design. Engineered for efficiency, it is capable of handling a wide range of fluids, including clean water, chemicals, and other industrial liquids. This pump is particularly known for its ability to operate under high-pressure conditions while maintaining a low energy consumption rate, which is a significant advantage in terms of operational costs.

The VMH26PR incorporates advanced hydraulic technologies, which enhance both performance and efficiency. The multistage configuration allows for higher pressure generation, making it ideal for applications that require elevated discharge pressures. Each stage is meticulously designed to optimize flow, reducing turbulence and maximizing throughput. This results in improved overall system efficiency and longevity of the pump.

In terms of materials, the VMH26PR offers various casing options tailored to the specific needs of the application, including stainless steel and cast iron. These materials provide excellent resistance to corrosion and wear, ensuring durability even in harsh environments. Additionally, the pump features mechanical seals designed to minimize leakage and enhance reliability.

Another significant technological aspect of the VMH26PR is its modular design. This allows for easy maintenance and component replacement, reducing downtime and service costs. Users can easily access vital parts without disassembling the entire unit, which is a considerable advantage for operation in critical settings.

Moreover, the Desa VMH26PR is equipped with a range of monitoring and control options, enabling seamless integration into automated processes. This feature enhances operational efficiency, allowing operators to monitor performance parameters in real-time and make data-driven decisions to optimize performance.

Overall, the Desa VMH26PR stands out with its combination of efficiency, durability, and ease of maintenance, making it an ideal solution for various fluid handling tasks across different industries. Its ability to adapt to specific requirements and conditions ensures it will meet the diverse needs of modern applications effectively.