CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.Remove screws that attach branch sup- port to fireplace (see Figure 24). Care- fully lift up branch support and remove from fireplace (see Figure 24).

3.Route flexible gas line (provided by installer) from manual shutoff valve into fireplace through side or rear ac- cess holes in outer casing. Route flex- ible gas supply line through fireplace access holes in outer casing.

NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line (see Figure 25) is provided to allow accessibility from the fireplace. The flexible gas supply line con- nection to the manual shutoff valve should be accessible.

4.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line (see Figure 25). Con- nect flexible gas line to flexible gas line attached to gas valve of fireplace (see Figure 25).

5.Check all gas connections for leaks. See Checking Gas Connections, page 15.

6.Replace branch support back into fire- place. Feed flexible gas line into fire- place base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reat- tach branch support to fireplace with screws removed in step 2.

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

Screen

Shipping

Screw

Shoulder

Screw

Screen

 

 

Branch

 

 

 

Support

 

Figure 24 - Removing Branch Support From Fireplace

 

Manual Shutoff Valve

 

Gas Connector

To Fireplace

 

 

 

 

Gas Valve

To Gas

Flexible Gas Line from

 

 

Supply

Flexible Gas Line from

 

Manual Shutoff Valve

Fireplace Gas Valve

 

Provided by Installer

Provided with Fireplace

 

Figure 25 - Attaching Flexible Gas Lines Together

 

14

104323

Image 14
Contents VENT-FREE PROPANE/LP GAS What to do if YOU Smell GASSafety Information Compact Classic Hearth FireplaceProduct Identification Product FeaturesRemote Control Accessories Local CodesAssembling Fireplace AssemblyInstalling Log Assembling HoodUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Locating FireplaceBUILT-IN Fireplace Installation Rough Opening for Installing in WallAssembling Brass Trim Brass trim shipped with mantel Optional Mantel InstallationMantel Clearances for Built-In Installation Installing Blower Assembly Installing Blower Accessory GA3400TRemoving Upper Louver Assembly For Built-In Installation Test to make sure the blower is work- ing properlyAttaching Wood Base to Solid Floor Connecting to GAS SupplyExtension Cord Connecting Fireplace to GAS Supply Installation Items NeededChecking GAS Connections Pressure Testing Fireplace Gas ConnectionsPressure Testing Gas Supply Piping System Installing 9-Volt Battery in Hand- Held Remote Control Unit Optional Wireless HAND- Held Remote Control AccessoriesInstalling Receiver Optional Wall Mounted Thermostat GWMT1Optional Wall Switch GWMS2 Route the 25 ft. wire to a convenientLighting Instructions For Your Safety Read Before LightingOperating Fireplace Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional GWMS2 Wall Mounted Switch OptionalOPERATINGGWMT1 Wall Fireplace Operating BlowerBurner Flame Pattern Inspecting BurnersPilot Flame Pattern Troubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Technical Service Cleaning and MaintenanceService Hints Wiring DiagramAccessories Specifications Replacement PartsIllustrated Parts Breakdown VMH26PR4Parts List VMH26PRWarranty Information International

VMH26PR specifications

Desa VMH26PR is a cutting-edge horizontal multistage pump designed for a variety of applications, primarily in industrial and municipal sectors. Its robust construction delivers excellent performance and reliability, making it a preferred choice for demanding environments.

One of the primary features of the VMH26PR is its versatile design. Engineered for efficiency, it is capable of handling a wide range of fluids, including clean water, chemicals, and other industrial liquids. This pump is particularly known for its ability to operate under high-pressure conditions while maintaining a low energy consumption rate, which is a significant advantage in terms of operational costs.

The VMH26PR incorporates advanced hydraulic technologies, which enhance both performance and efficiency. The multistage configuration allows for higher pressure generation, making it ideal for applications that require elevated discharge pressures. Each stage is meticulously designed to optimize flow, reducing turbulence and maximizing throughput. This results in improved overall system efficiency and longevity of the pump.

In terms of materials, the VMH26PR offers various casing options tailored to the specific needs of the application, including stainless steel and cast iron. These materials provide excellent resistance to corrosion and wear, ensuring durability even in harsh environments. Additionally, the pump features mechanical seals designed to minimize leakage and enhance reliability.

Another significant technological aspect of the VMH26PR is its modular design. This allows for easy maintenance and component replacement, reducing downtime and service costs. Users can easily access vital parts without disassembling the entire unit, which is a considerable advantage for operation in critical settings.

Moreover, the Desa VMH26PR is equipped with a range of monitoring and control options, enabling seamless integration into automated processes. This feature enhances operational efficiency, allowing operators to monitor performance parameters in real-time and make data-driven decisions to optimize performance.

Overall, the Desa VMH26PR stands out with its combination of efficiency, durability, and ease of maintenance, making it an ideal solution for various fluid handling tasks across different industries. Its ability to adapt to specific requirements and conditions ensures it will meet the diverse needs of modern applications effectively.