Vermont Casting DV580 manual Rear Wall Vent Installation Twist Lock Pipe

Page 14

DV360/580 Series Direct Vent Gas Fireplace

Vent Opening for Combustible Walls

 

 

 

 

 

 

 

 

Rear Vent Top View

20” (508 mm)

 

 

 

 

Max.

 

 

 

 

 

 

 

 

 

 

 

 

DVR584-600

Fig. 20 Rear vent application, no elbows.

9³⁄

(240 mm)

10³⁄

(265 mm)

Fireplace Hearth

Framing Detail

 

20”

20”

 

(508 mm)

 

(508 mm)

 

Max.

 

Max.

 

 

45°

 

45°

Rear Vent Top View, Corner Installation

FP836

Fig. 21 Rear vent application, one 45° elbow.

Rear Wall Vent Installation

Twist Lock Pipe

Step 1

Locate and cut the vent opening in the wall.

For combustible walls first frame in opening. (Fig. 22)

NOTE: When using flex vent, the opening will have to be measured according to the 1” (25mm) rise in 24” (610mm) vertical run.

Combustible Walls: Cut a 10³⁄”H x 9³⁄” W (265 mm x 240 mm) hole through the exterior wall and frame as shown. (Fig. 22)

Noncombustible Walls: Hole opening should be 7¹⁄” (191mm) diameter.

Zero clearance sleeve is only required for combustible walls.

Step 2

Measure wall thickness and cut zero clearance sleeve parts to proper length (Maximum 12” / 305 mm). As- semble sleeve to its maximum opening (10³⁄” x 9³₈”) and attach to firestop assembly. (Fig. 23)

Step 3

Measure the horizontal length requirement for the vent- ing including a 2” (51 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (51 mm). (Fig. 21)

Opening for Noncombustible Wall

7¹⁄

 

(190 mm)

 

Fireplace Hearth

VO584-100

Fig. 22 Locate vent opening on wall.

 

Adjustable Zero

Max. Length

Clearance Sleeve

12” (305 mm)

 

 

#8 Screws (2)

#8 Screws

 

(2)

 

 

#8 Screws

 

(2)

Firestop

Adjustable Zero

 

Clearance Sleeve

ZCS101

Fig. 23 Adjustable zero clearance sleeve.

 

Step 4

Install the 4” (102 mm) vent to the appliance collar and secure with 3 sheet metal screws. Install the 7” (178

mm)vent pipe to the appliance collar and secure with 3 sheet metal screws. It is not necessary to seal this con- nection. If a 45° elbow is being used attach the elbow to the appliance in the same manner then attach the venting to the elbow.

It is critical that there is no downward slope away from the appliance when con- necting the vent or elbow.

Step 5

Guide the venting through the vent hole as you place the appliance in its installed position. Guide the 4”

(102 mm) and 7” (178 mm) collar of the vent termina- tion into the outer ends of the venting. Do not force the termination. If the vent pipes do not align with the termination, remove and realign the venting at the appli- ance flue collars. (Fig. 24) Attach the termination to the wall as outlined in the instruction sheet supplied with the termination.

20010667

15

Image 14
Contents Direct Vent Gas Fireplace Installation & Operating Instructions Locating Your FireplaceFireplace Dimensions Installed as Top Vent DV360 DV580Fireplace Dimensions Installed as Rear Vent Framing DimensionsHearth Clearance to CombustiblesMantels Gas Specifications Framing And FinishingFinal Finishing Gas Inlet and Manifold PressuresAlternate Switch Location Gas Line InstallationRemote ON/OFF Switch Installation When purging gas line the front glass must be removedEB-1 Electrical Box Electronic Gas Control ValveOptional Top Vent Application Complete conversionGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationFlex Vent Pipes Canadian InstallationsUSA Installations Rear Wall Vent Application How to Use the Vent GraphTwist Lock Pipes Rear Wall Vent Installation Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall ApplicationVertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level plane+ B = 17 Max Vertical Sidewall Installation Flex Vent Pipe Horizontal length requirementBelow Grade Installation Vertical Through-the-Roof ApplicationVertical Through-the-Roof Installation Maximum elbow usageMin 610 mm Venting Components Installation of Optional Ceramic Panels Window Frame Assembly RemovalGlass Cleaning Replacement Ceramic Hearth PanelsDV360 Installation of LogsLog Identification Chart Logs DV360 DV580Log Overlay Top logs must be placed properly onto notches DV580Refer to Figure Flame Characteristics Burner Lava Rock PlacementFlame & Temperature Adjustment Large Lava RockDV360 DV580On Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Instructions for RF Comfort Control ValveFan Override During Auto Mode Delay Timer ModeAuto Mode Change Between F/C Temperature UnitsLED Count Service Action Auto PathOn Path Local Path Using a 1/2 open end wrench remove the orifices. Fig Pilot Orifice Conversion Installation PrecautionsConversion Procedure Burner Orifice Conversion DV360Injector Orifice Size Matrix DV360/580 DV360/580 Description DV580 GACA4P0 Fuel Conversion Kits Hard Direct Wire Hook Up FK12 Fan AssemblyFK24 Fan Assembly Fan KitsCeramic Refractory Panels Remote ControlsInstallation Instructions Decorative Bay WindowsFor Use in Mobile Homes Model DV360RMH Conversion Instructions9b.Units with Honeywell valve Limited Lifetime Warranty Efficiency Ratings AFUE%

DV580 specifications

The Vermont Casting DV580 is a remarkable direct vent gas fireplace that combines modern technology with the timeless craftsmanship that Vermont Castings is renowned for. This fireplace offers an exceptional combination of efficiency, style, and function, making it an ideal choice for homeowners seeking both aesthetic appeal and comfortable warmth.

One of the most significant features of the DV580 is its impressive heating capacity. With a maximum output of 33,000 BTUs, it is capable of heating spaces up to 1,800 square feet, depending on the layout of the home. This means you can enjoy consistent warmth throughout your living space, even during the coldest winter months.

Another notable characteristic is its direct vent technology, which allows for safe and efficient operation. The DV580 draws air from outside and expels combustion gases directly outdoors, minimizing indoor air pollution and ensuring optimal combustion. This design not only improves energy efficiency but also contributes to a healthier indoor environment.

The aesthetic appeal of the DV580 is enhanced by its large viewing area, which presents a beautiful flame display. The fireplace features a realistic log set that captures the look of a traditional wood-burning fire, complemented by a variety of decorative trim options. Available in both a traditional and contemporary design, the DV580 can seamlessly integrate into diverse home styles.

Vermont Castings also prioritizes user-friendliness with the DV580. An intuitive control panel allows for easy adjustments to the flame height and heat output, ensuring that homeowners can customize their experience. Additionally, an optional remote control offers added convenience, allowing users to manage the fireplace from the comfort of their seating area.

Durability is another hallmark of the DV580. Constructed from high-quality materials, it is designed to withstand the test of time. The unit is backed by a solid warranty, reflecting the manufacturer’s confidence in its reliability and performance.

In summary, the Vermont Casting DV580 is a premier gas fireplace that beautifully marries form and function. With its efficient heating capabilities, direct vent technology, stunning aesthetic options, and user-centric features, it stands out as a top choice for those looking to elevate their living space while enjoying the cozy warmth of a fireplace.