Vermont Casting DV580 manual Refer to Figure, Top logs must be placed properly onto notches

Page 26
Log
Rear

6. Place the log top cen-

DV360/580 Series Direct Vent Gas Fireplace

Figure 54

ter. Hold the log with

the pointed end toward the back. Match the two holes on the bottom of the log with the two pins

on the top of the log front right. (Refer to Figure 53 for pin loca- tions) Set the log and lay it into the rear log. (Fig. 54)

7.

Place the log top right. Hold the

 

log with pointed end to the left.

 

Match the two holes on the bot-

 

tom of the log with the two pins

 

on the rear log and set the fork

 

on the log over the right front

 

log. (Fig. 54)

8.

Place the lava rock on the

 

hearth refractory in the front

Log Top Center

Log Top Right

Log

Front

Right

LG464

as desired. (Fig. 54)

Log Front Left

Lava Rock

 

DV580

Refer to Figure 51.

1. Place rear log (E8) on rear

bracket (ensure the notch on

the left end is centered on

the left side of rear bracket),

so it will not move from side

to side and is firmly posi-

Log Top Left

(E12)Log Rear

(E8)

Log Top Right (E13)

 

tioned on the bracket. Be

 

sure log is as far forward as

 

possible on bracket. (Fig. 55)

2.

Place front left log (E9) on

 

top of burner, left side. Align

 

log’s bottom holes with left

 

bracket log locator studs.

3.

Place front right log (E10)

 

on top of burner, right side.

 

Align log’s bottom holes

 

with right bracket log locator

 

studs. (Fig. 50)

4.

Place top left log (E12). Use

Log Front Left (E9)

Log Front Right (E10)

log’s bottom hole to locate

it onto rear log left (E8) and

just rest bottom cut out log

onto the grate assembly.

Burner Lava Rock and

Log Front

 

1/3 of the bag of Embers

 

Center (E11)

LG395

 

 

 

Fig. 55 DV580 log, burner lava rock and ember placement.

5.Place top right log (E13).

Use log’s bottom hole to locate it onto rear log right (E8) and the bottom of top right log rest onto front right log (E10).

6.Place front center log (E11). Position the log notch against the center grate assembly and the bottom of front center log rest onto front right log (E10).

7. Place large lava rock around the front grate.

Top logs must be placed properly onto notches.

20010667

27

Image 26
Contents Direct Vent Gas Fireplace Installation & Operating Instructions Locating Your FireplaceFireplace Dimensions Installed as Top Vent DV360 DV580Fireplace Dimensions Installed as Rear Vent Framing DimensionsHearth Clearance to CombustiblesMantels Gas Specifications Framing And FinishingFinal Finishing Gas Inlet and Manifold PressuresAlternate Switch Location Gas Line InstallationRemote ON/OFF Switch Installation When purging gas line the front glass must be removedEB-1 Electrical Box Electronic Gas Control ValveOptional Top Vent Application Complete conversionGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationFlex Vent Pipes Canadian InstallationsUSA Installations Rear Wall Vent Application How to Use the Vent GraphTwist Lock Pipes Rear Wall Vent Installation Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall ApplicationVertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level plane+ B = 17 Max Vertical Sidewall Installation Flex Vent Pipe Horizontal length requirementBelow Grade Installation Vertical Through-the-Roof ApplicationVertical Through-the-Roof Installation Maximum elbow usageMin 610 mm Venting Components Installation of Optional Ceramic Panels Window Frame Assembly RemovalGlass Cleaning Replacement Ceramic Hearth PanelsDV360 Installation of LogsLog Identification Chart Logs DV360 DV580Log Overlay Top logs must be placed properly onto notches DV580Refer to Figure Flame Characteristics Burner Lava Rock PlacementFlame & Temperature Adjustment Large Lava RockDV360 DV580On Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Instructions for RF Comfort Control ValveFan Override During Auto Mode Delay Timer ModeAuto Mode Change Between F/C Temperature UnitsLED Count Service Action Auto PathOn Path Local Path Using a 1/2 open end wrench remove the orifices. Fig Pilot Orifice Conversion Installation PrecautionsConversion Procedure Burner Orifice Conversion DV360Injector Orifice Size Matrix DV360/580 DV360/580 Description DV580 GACA4P0 Fuel Conversion Kits Hard Direct Wire Hook Up FK12 Fan AssemblyFK24 Fan Assembly Fan KitsCeramic Refractory Panels Remote ControlsInstallation Instructions Decorative Bay WindowsFor Use in Mobile Homes Model DV360RMH Conversion Instructions9b.Units with Honeywell valve Limited Lifetime Warranty Efficiency Ratings AFUE%

DV580 specifications

The Vermont Casting DV580 is a remarkable direct vent gas fireplace that combines modern technology with the timeless craftsmanship that Vermont Castings is renowned for. This fireplace offers an exceptional combination of efficiency, style, and function, making it an ideal choice for homeowners seeking both aesthetic appeal and comfortable warmth.

One of the most significant features of the DV580 is its impressive heating capacity. With a maximum output of 33,000 BTUs, it is capable of heating spaces up to 1,800 square feet, depending on the layout of the home. This means you can enjoy consistent warmth throughout your living space, even during the coldest winter months.

Another notable characteristic is its direct vent technology, which allows for safe and efficient operation. The DV580 draws air from outside and expels combustion gases directly outdoors, minimizing indoor air pollution and ensuring optimal combustion. This design not only improves energy efficiency but also contributes to a healthier indoor environment.

The aesthetic appeal of the DV580 is enhanced by its large viewing area, which presents a beautiful flame display. The fireplace features a realistic log set that captures the look of a traditional wood-burning fire, complemented by a variety of decorative trim options. Available in both a traditional and contemporary design, the DV580 can seamlessly integrate into diverse home styles.

Vermont Castings also prioritizes user-friendliness with the DV580. An intuitive control panel allows for easy adjustments to the flame height and heat output, ensuring that homeowners can customize their experience. Additionally, an optional remote control offers added convenience, allowing users to manage the fireplace from the comfort of their seating area.

Durability is another hallmark of the DV580. Constructed from high-quality materials, it is designed to withstand the test of time. The unit is backed by a solid warranty, reflecting the manufacturer’s confidence in its reliability and performance.

In summary, the Vermont Casting DV580 is a premier gas fireplace that beautifully marries form and function. With its efficient heating capabilities, direct vent technology, stunning aesthetic options, and user-centric features, it stands out as a top choice for those looking to elevate their living space while enjoying the cozy warmth of a fireplace.