Vermont Casting DV580 manual Vertical Sidewall Installation Flex Vent Pipe

Page 18

X

X

FP1182

Fig. 35 Horizontal length requirement.

Step 7

Apply high temperature sealant to 4” (102 mm) and 7” (178 mm) collars or the termination one inch away from crimped end. Guide the vent terminations 4” and 7” collard into their respective vent pipes. Double check that the vent pipes overlap the collars by 2” (51 mm). Secure the termination to the wall with screws provided and caulk around the wall plate to weatherproof. As an alternative to screwing the termination directly to the wall, you may also use expanding plugs or an approved exterior construction adhesive. You may also attach the termination with screws through the inner body into the 4” vent pipe, however for this method, you must extend the 4” pipe approximately 6” (152 mm) beyond the outer face of the wall.

Support horizontal pipes every 36” (914 mm) with metal pipe straps.

Vertical Sidewall Installation

Flex Vent Pipe

NOTE: The 40” (1016 mm) flex vent is used for 90° off the top of the unit then out the back wall.

Follow Step 1 and 2 on Page 18.

Step 3

Install the four (4) spacer springs on the 4” flex vent pipe. When installing the spacer springs around the 4” pipe, stretch the spring to approximately 15” (381 mm), wrap the spring around the pipe and interlock the ends of the spacer spring approximately 2” (51 mm). Mea- sure 6³⁄” (172 mm) from the end of the pipe. Place the next spring 5” (127 mm) from the previously installed spring. Place the next spring 6” (152 mm) from the last spring. Finally place the last spring 12” (305 mm) from the last spring installed. (Fig. 36)

DV360/580 Series Direct Vent Gas Fireplace

4” Flex Vent Pipe

12"

(305mm)

Spacer Spring

6"

(152mm)

5"

(127mm)

6³⁄"

(172mm)

FP1474

Fig. 36 Install spacer springs.

Step 4

Install the 4” (102 mm) flex vent pipe to the appliance collar as described on Page 13. Secure the end with the first spring 6³⁄” (172 mm) from the flex pipe end to the unit.

Step 5

Slide the 7” (178 mm) flex vent pipe over the 4” flex vent pipe and secure the 7” collar as described on Page 13.

Step 6

Bend the flex pipe horizontal so the bottom of the hori- zontal pipe measure 6¹⁄” (165 mm) from the top of the unit immediately after the 90° formation. (Fig. 37) Be sure to follow the 1/2” (13 mm) rise in a 12” (305 mm) horizontal run rule.

Step 7

Install the 4” flex then 7” flex to the termination.

6¹⁄" (165mm)

FP1475

Fig. 37 Bend flex vent at 90° so horizontal portion is 6¹⁄₂” (165 mm) off top of unit.

20010667

19

Image 18
Contents Direct Vent Gas Fireplace Installation & Operating Instructions Locating Your FireplaceFireplace Dimensions Installed as Top Vent DV360 DV580Fireplace Dimensions Installed as Rear Vent Framing DimensionsClearance to Combustibles MantelsHearth Gas Specifications Framing And FinishingFinal Finishing Gas Inlet and Manifold PressuresAlternate Switch Location Gas Line InstallationRemote ON/OFF Switch Installation When purging gas line the front glass must be removedEB-1 Electrical Box Electronic Gas Control ValveOptional Top Vent Application Complete conversionGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsFlex Vent Pipes How to Use the Vent Graph Twist Lock PipesRear Wall Vent Application Rear Wall Vent Installation Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall ApplicationVertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level plane+ B = 17 Max Vertical Sidewall Installation Flex Vent Pipe Horizontal length requirementBelow Grade Installation Vertical Through-the-Roof ApplicationVertical Through-the-Roof Installation Maximum elbow usageMin 610 mm Venting Components Installation of Optional Ceramic Panels Window Frame Assembly RemovalGlass Cleaning Replacement Ceramic Hearth PanelsDV360 Installation of LogsLog Identification Chart Logs DV360 DV580Log Overlay DV580 Refer to FigureTop logs must be placed properly onto notches Flame Characteristics Burner Lava Rock PlacementFlame & Temperature Adjustment Large Lava RockDV360 DV580On Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Instructions for RF Comfort Control ValveFan Override During Auto Mode Delay Timer ModeAuto Mode Change Between F/C Temperature UnitsLED Count Service Action Auto PathOn Path Local Path Using a 1/2 open end wrench remove the orifices. Fig Pilot Orifice Conversion Installation PrecautionsConversion Procedure Burner Orifice Conversion DV360Injector Orifice Size Matrix DV360/580 DV360/580 Description DV580 GACA4P0 Fuel Conversion Kits Hard Direct Wire Hook Up FK12 Fan AssemblyFK24 Fan Assembly Fan KitsCeramic Refractory Panels Remote ControlsInstallation Instructions Decorative Bay WindowsFor Use in Mobile Homes Model DV360RMH Conversion Instructions9b.Units with Honeywell valve Limited Lifetime Warranty Efficiency Ratings AFUE%

DV580 specifications

The Vermont Casting DV580 is a remarkable direct vent gas fireplace that combines modern technology with the timeless craftsmanship that Vermont Castings is renowned for. This fireplace offers an exceptional combination of efficiency, style, and function, making it an ideal choice for homeowners seeking both aesthetic appeal and comfortable warmth.

One of the most significant features of the DV580 is its impressive heating capacity. With a maximum output of 33,000 BTUs, it is capable of heating spaces up to 1,800 square feet, depending on the layout of the home. This means you can enjoy consistent warmth throughout your living space, even during the coldest winter months.

Another notable characteristic is its direct vent technology, which allows for safe and efficient operation. The DV580 draws air from outside and expels combustion gases directly outdoors, minimizing indoor air pollution and ensuring optimal combustion. This design not only improves energy efficiency but also contributes to a healthier indoor environment.

The aesthetic appeal of the DV580 is enhanced by its large viewing area, which presents a beautiful flame display. The fireplace features a realistic log set that captures the look of a traditional wood-burning fire, complemented by a variety of decorative trim options. Available in both a traditional and contemporary design, the DV580 can seamlessly integrate into diverse home styles.

Vermont Castings also prioritizes user-friendliness with the DV580. An intuitive control panel allows for easy adjustments to the flame height and heat output, ensuring that homeowners can customize their experience. Additionally, an optional remote control offers added convenience, allowing users to manage the fireplace from the comfort of their seating area.

Durability is another hallmark of the DV580. Constructed from high-quality materials, it is designed to withstand the test of time. The unit is backed by a solid warranty, reflecting the manufacturer’s confidence in its reliability and performance.

In summary, the Vermont Casting DV580 is a premier gas fireplace that beautifully marries form and function. With its efficient heating capabilities, direct vent technology, stunning aesthetic options, and user-centric features, it stands out as a top choice for those looking to elevate their living space while enjoying the cozy warmth of a fireplace.