Vermont Casting DV580 manual Below Grade Installation, Vertical Through-the-Roof Application

Page 19

DV360/580 Series Direct Vent Gas Fireplace

Below Grade Installation

When it is not possible to meet the required vent ter- minal clearances of 12” (305 mm) above grade level, a snorkel kit is recommended. It allows installation depth down to 7” (178 mm) below grade level. The 7” (178

mm)is measured from the center of the horizontal vent pipe as it penetrates through the wall.

Ensure the sidewall venting clearances are ob- served. If venting system is installed below ground, we recommend a window well with adequate and proper drainage to be installed around the termina- tion area.

Do not back fill around snorkel.

A clearance of at least 4” must be main- tained between the snorkel and the soil.

If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fas- ten brackets to wall first, then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes out as far as the protruding wall face. (Fig. 39)

If installing a snorkel, a minimum 24” (610 mm) vertical rise is necessary. The maximum horizontal run with the 24” vertical pipe is 36” (914 mm). This measurement is taken from the collar of the fireplace (or transition elbow) to the face of the exterior wall. See the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 24” (610 mm).

1.

Establish vent hole through the wall (Fig. 32)

2.

Remove soil to a depth of approximately 16”

 

(406mm) below base of snorkel. Install drain pipe.

Foundation

Recess

Watertight

Seal Around

PIpe

Snorkel

Wall Screws

Sheet Metal Screws

BG401

 

Install window well (not supplied). Refill hole with 12”

 

(305 mm) of coarse gravel leaving a clearance of ap-

 

proximately 4” (102 mm) below snorkel. (Fig. 38)

3.

Install vent system.

4.

Ensure a watertight seal is made around the vent

 

pipe coming through the wall.

5.

Apply high temperature sealant caulking (supplied)

 

around the 4” and 7” snorkel collars.

6.

Slide the snorkel into the vent pipes and secure to

 

the wall.

7.

Level the soil so as to maintain a 4” (102 mm) clear-

 

ance below snorkel. (Fig. 38)

Fig. 39 Snorkel installation, recessed foundation.

Vertical Through-the-Roof Application

This gas fireplace has been approved for:

Vertical installations up to 40’ (12 m) in height. Up to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. (Fig. 40)

Up to two 45° elbows may be used within the hori- zontal run. For each 45° elbow used on the horizon- tal plane, the maximum horizontal length must be reduced by 18” (450 mm).

Zero Clearance Sleeve

(if required)

Firestop

7” Pipe

24” (610mm) Minimum*

Screws

7TDVSNORK

(Snorkel)

4” (102mm) Clearance Min.

Window

Well

Gravel

Drain

Foundation Wall

*A minimum of 24” (610 mm) vertical pipe must be installed when using the 7TDVSNORK Kit.

Example: Maximum horizontal length:

No elbows

= 10’ (3 m)

1 x 45° elbow

= 8.5’ (2.6 m)

2 x 45° elbows = 7’ (2.1 m)

A minimum of an 8’ (2.5 m) vertical rise is required.

Two sets of 45° elbow offsets may be used within the vertical sections. From 0 to a maximum of 8’ (2.5 m) of vent pipe can be used between elbows. (Fig. 41)

7DVCS supports offsets. (Fig. 43) This application will require that you first determine the roof pitch and use the appropriate starter kit. (Refer to Venting Components List)

The maximum angular variation allowed in the sys- tem is 270°. (Fig. 41)

The minimum height of the vent above the highest point of penetration through the roof is 2’ (610 mm). (Fig. 44) Refer to note 2, Page 14.

BG402a

Fig. 38 Below grade installation.

20

20010667

Image 19
Contents Direct Vent Gas Fireplace Locating Your Fireplace Installation & Operating InstructionsDV360 DV580 Fireplace Dimensions Installed as Top VentFraming Dimensions Fireplace Dimensions Installed as Rear VentMantels Clearance to CombustiblesHearth Gas Inlet and Manifold Pressures Framing And FinishingFinal Finishing Gas SpecificationsWhen purging gas line the front glass must be removed Gas Line InstallationRemote ON/OFF Switch Installation Alternate Switch LocationElectronic Gas Control Valve EB-1 Electrical BoxComplete conversion Optional Top Vent ApplicationLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsFlex Vent Pipes Twist Lock Pipes How to Use the Vent GraphRear Wall Vent Application Zero clearance sleeve is only required for combustible walls Rear Wall Vent Installation Twist Lock PipeVertical Sidewall Application Rear Wall Vent Installations Flex Vent PipeAlways install horizontal venting on a level plane Vertical Sidewall Installation Twist Lock Pipe+ B = 17 Max Horizontal length requirement Vertical Sidewall Installation Flex Vent PipeVertical Through-the-Roof Application Below Grade InstallationMaximum elbow usage Vertical Through-the-Roof InstallationMin 610 mm Venting Components Replacement Ceramic Hearth Panels Window Frame Assembly RemovalGlass Cleaning Installation of Optional Ceramic PanelsLogs DV360 DV580 Installation of LogsLog Identification Chart DV360Log Overlay Refer to Figure DV580Top logs must be placed properly onto notches Large Lava Rock Burner Lava Rock PlacementFlame & Temperature Adjustment Flame CharacteristicsDV580 DV360Instructions for RF Comfort Control Valve Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeChange Between F/C Temperature Units Delay Timer ModeAuto Mode Fan Override During Auto ModeAuto Path LED Count Service ActionOn Path Local Path Using a 1/2 open end wrench remove the orifices. Fig Burner Orifice Conversion DV360 Installation PrecautionsConversion Procedure Pilot Orifice ConversionInjector Orifice Size Matrix DV360/580 DV360/580 Description DV580 GACA4P0 Fuel Conversion Kits Fan Kits FK12 Fan AssemblyFK24 Fan Assembly Hard Direct Wire Hook UpDecorative Bay Windows Remote ControlsInstallation Instructions Ceramic Refractory PanelsConversion Instructions For Use in Mobile Homes Model DV360RMH9b.Units with Honeywell valve Limited Lifetime Warranty AFUE% Efficiency Ratings

DV580 specifications

The Vermont Casting DV580 is a remarkable direct vent gas fireplace that combines modern technology with the timeless craftsmanship that Vermont Castings is renowned for. This fireplace offers an exceptional combination of efficiency, style, and function, making it an ideal choice for homeowners seeking both aesthetic appeal and comfortable warmth.

One of the most significant features of the DV580 is its impressive heating capacity. With a maximum output of 33,000 BTUs, it is capable of heating spaces up to 1,800 square feet, depending on the layout of the home. This means you can enjoy consistent warmth throughout your living space, even during the coldest winter months.

Another notable characteristic is its direct vent technology, which allows for safe and efficient operation. The DV580 draws air from outside and expels combustion gases directly outdoors, minimizing indoor air pollution and ensuring optimal combustion. This design not only improves energy efficiency but also contributes to a healthier indoor environment.

The aesthetic appeal of the DV580 is enhanced by its large viewing area, which presents a beautiful flame display. The fireplace features a realistic log set that captures the look of a traditional wood-burning fire, complemented by a variety of decorative trim options. Available in both a traditional and contemporary design, the DV580 can seamlessly integrate into diverse home styles.

Vermont Castings also prioritizes user-friendliness with the DV580. An intuitive control panel allows for easy adjustments to the flame height and heat output, ensuring that homeowners can customize their experience. Additionally, an optional remote control offers added convenience, allowing users to manage the fireplace from the comfort of their seating area.

Durability is another hallmark of the DV580. Constructed from high-quality materials, it is designed to withstand the test of time. The unit is backed by a solid warranty, reflecting the manufacturer’s confidence in its reliability and performance.

In summary, the Vermont Casting DV580 is a premier gas fireplace that beautifully marries form and function. With its efficient heating capabilities, direct vent technology, stunning aesthetic options, and user-centric features, it stands out as a top choice for those looking to elevate their living space while enjoying the cozy warmth of a fireplace.