Vermont Casting 20DVT Vertical Sidewall Installation Twist Lock Pipe, Total angular variation =

Page 11

Horizontal plane means no vertical rise exists on this portion of the vent assembly.

The maximum number of 90° elbows per side wall installation is three (3). (Fig. 11)

If a 90° elbow is fitted directly on top of the fireplace flange, the maximum horizontal vent run before the termination or a vertical rise is 36” (914 mm). (Fig.

12)

If a 90° elbow is used in the horizontal vent run (level height maintained) the maximum horizontal vent length is reduced by 36” (914 mm). (Fig. 12) This does not apply if the 90° elbows are used to increase or redirect a vertical rise. (Fig. 13)

3 x 90° Elbows

FP1176

Fig. 11 Maximum three (3) 90° elbows per installation.

36"

(914 mm)

Max. 36"

(914 mm) Max.

FP1177

Fig. 12 Maximum horizontal run with no rise.

AB

A + B = 17' (Max.)

(5.2m)

7'6"

(2.3m)

FP1178

Fig. 13 Horizontal run reduction.

Brookhaven Direct Vent Gas Fireplace

Example: According to the vent graph (Page 10) the maximum horizontal vent length in a system with a 7.5’ (2.3 m) vertical rise is 20’ (6 m) and if a 90° elbow is required in the horizontal vent it must be reduced to 17’ (5.2 m). In Figure 13 Dimension A plus B must not be greater than 17’ (5.2 m).

The maximum number of 45° elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run.

For each 45° elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18” (45 cm). This does not apply if the 45° elbows are installed on the vertical part of the vent system.

The maximum number of elbow degrees in a system is 270°. (Fig. 14)

Example:

Elbow 1 = 90°

Elbow 2 = 45°

Elbow 3 = 45°

Elbow 4 = 90°

Total angular variation = 270°

1 + 2 + 3 + 4 = 270°

1

2

3

4

FP1180

Fig. 14 Maximum elbow usage.

Vertical Sidewall Installation

Twist Lock Pipe

STEP 1

Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size. (Fig. 15) (For combustible walls first frame in opening.)

NOTE: When using flex vent, the opening will have to be measured according to the 1/2” (13 mm) rise in 12” (305 mm) vent run.

Combustible Walls (Fig. 15): Cut a 9³⁄”H x 9³⁄” W (240 x 240 mm) hole through the exterior wall and frame.

Noncombustible Walls (Fig. 15): Hole opening must be 7.5” (190 mm) in diameter.

10009459

11

Image 11
Contents Brookhaven Direct Vent Model 20DVT Table of Contents Please Review the Following Carefully Installation & Operating InstructionsLocating Your Fireplace 20DVT 20DVT Fireplace DimensionsFraming Dimensions Hearth Clearance to CombustiblesMantels Gas Specifications Gas Line InstallationFraming and Finishing Final FinishingLocation of Vent Termination Remote ON/OFF SwitchGeneral Venting General Venting Information Termination Location Canadian Installations1 US Installations2Flex Vent Pipes Canadian InstallationsUSA Installations General Information Assembling Vent PipesExample a How to Use the Vent GraphTwist Lock Pipes Vertical Sidewall ApplicationsStep Vertical Sidewall Installation Twist Lock PipeTotal angular variation = Zero clearance sleeve is only required for combustible walls Always install horizontal venting on a level planeBelow Grade Installations Vertical Sidewall Installation Flex Vent PipeVertical Through-the-Roof Application Vertical Through-the-Roof InstallationVenting supports Venting Components Glass Information Glass CleaningWindow Frame Assembly Removal Operating InstructionsLogs 20DVT Installation of LogsLog Identification Chart Log InstallationInspecting the Venting System Flame & Temperature AdjustmentFlame Characteristics Large Lava RockWhat to do if YOU Smell GAS To Turn Off Gas To HeaterSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemBurner Orifice Conversion ProceedingNova SIT820 Valve Conversion Pilot Orifice Conversion Burner and Burner Compartment MaintenanceCleaning the Standing Pilot Control System 8a,b 7a,b DescriptionFuel Conversion Kits 20DVTOptional Trim Kits Optional Accessories AvailableRemote Controls Ceramic Refractory PanelsBrookhaven Direct Vent Gas Fireplace Brookhaven Direct Vent Gas Fireplace Brookhaven Direct Vent Gas Fireplace If Warranty Service is NEEDED… Product Covered by this WarrantyAFUE% Efficiency Ratings