Vermont Casting 20DVT Troubleshooting the Gas Control System, SIT Nova 820 Millivolt Valve

Page 21

Brookhaven Direct Vent Gas Fireplace

Troubleshooting the Gas Control System

SIT NOVA 820 MILLIVOLT VALVE

NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position.

WARNING: REMOVE GLASS FRONT BEFORE DOING ANY GAS CONTROL SERVICE WORK.

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

 

 

 

1. Spark ignitor will not light

A. Defective or misaligned

Using a match, light pilot. If pilot lights, turn off

 

electrode at pilot.

pilot and push the red button again. If pilot will not

 

 

light, check the gap at electrode and pilot; it should

 

 

be 1/8” to have a strong spark.

 

B. Defective ignitor (Push Button)

Push piezo Ignitor Button. Check for spark at

 

 

electrode and pilot. If no spark to pilot, and electode

 

 

wire is properly connected, replace ignitor.

2. Pilot will not stay lit after

A. Defective pilot generator

Check pilot flame. Must impinge on thermocouple/

carefully following lighting

(thermocouple), remote wall

thermopile. NOTE: This pilot burner assembly

instructions.

switch.

utilizes both a thermocouple and a thermopile.

 

 

The thermocouple operates the main valve opera-

 

 

tion (ON/OFF). Clean and/or adjust pilot for maxi-

 

 

mum flame impingement on thermopile and thermo-

 

 

couple.

 

B. Defective automatic valve

Turn valve knob to “Pilot.” Maintain flow to pilot;

 

 

millivolt meter should read greater than 10 mV. If

 

 

the reading is okay and the pilot does not stay on,

 

 

replace the gas valve. NOTE: An interrupter block

 

 

(not supplied) must be used to conduct this test.

3. Pilot burning, no gas to

A. Wall switch or wires defective

Check wall switch and wires for proper connections

main burner

 

Jumper wires across terminals at wall switch; if

 

 

burner comes on, repalce defective wall switch. If

 

 

okay, jumper wires across wall switch wires at valve;

 

 

if burner comes on, wires are faulty or connections

 

 

are bad.

 

B. Thermopile may not be

1. Be sure wire connections from thermopile at

 

generating sufficient

gas valve terminals are tight and thermopile is

 

millivoltage.

fully inserted into pilot bracket.

 

 

2. One of the wall switch wires may be grounded.

 

 

Remove wall switch wires from valve terminals if

 

 

pilot now stays lit, trace wall switch wiring for

 

 

ground. May be grounded to fireplace or gas

 

 

supply.

 

 

3. Check thermopile with millivolt meter. Take

 

 

reading at thermopile terminals of gas valve—

 

 

should read 250-300 millivolts (minimum 150)

 

 

while holding valve knob depressed in pilot

 

 

position and wall switch “OFF.” Replace faulty

 

 

thermopile if reading is below specified minimum.

 

C. Plugged burner orifice.

Check burner orifices for debris and remove.

 

D. Defective automatic valve

Turn valve knob to “ON,” place wall switch to “ON” —

 

operator.

millivolt meter should read greater than 100 mV. If

 

 

the reading is okay and the burner does not come

 

 

on, replace the gas valve.

4. Frequent pilot outage

A. Pilot flame may be too low

Clean and/or adjust pilot flame for maximum flame

problem.

or blowing (high) causing the

impingement on thermopile and thermocouple.

 

pilot safety to drop out.

 

 

B. Possible blockage of the vent

Check the vent terminal for blockage (recycling the

 

terminal.

flue gases)

 

C. Low gas supply pressure

Check gas supply pressure to be between minimum

 

 

and maximum with the burner in the “ON” position.

10009459

21

Image 21
Contents Brookhaven Direct Vent Model 20DVT Table of Contents Installation & Operating Instructions Locating Your FireplacePlease Review the Following Carefully 20DVT Fireplace Dimensions Framing Dimensions20DVT Clearance to Combustibles MantelsHearth Framing and Finishing Gas Line InstallationFinal Finishing Gas SpecificationsRemote ON/OFF Switch General VentingLocation of Vent Termination General Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesTwist Lock Pipes How to Use the Vent GraphVertical Sidewall Applications Example aVertical Sidewall Installation Twist Lock Pipe Total angular variation =Step Zero clearance sleeve is only required for combustible walls Always install horizontal venting on a level planeBelow Grade Installations Vertical Sidewall Installation Flex Vent PipeVertical Through-the-Roof Application Vertical Through-the-Roof InstallationVenting supports Venting Components Window Frame Assembly Removal Glass CleaningOperating Instructions Glass InformationLog Identification Chart Installation of LogsLog Installation Logs 20DVTFlame Characteristics Flame & Temperature AdjustmentLarge Lava Rock Inspecting the Venting SystemWhat to do if YOU Smell GAS To Turn Off Gas To HeaterSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemProceeding Nova SIT820 Valve ConversionBurner Orifice Conversion Pilot Orifice Conversion Maintenance Cleaning the Standing Pilot Control SystemBurner and Burner Compartment 8a,b 7a,b DescriptionFuel Conversion Kits 20DVTRemote Controls Optional Accessories AvailableCeramic Refractory Panels Optional Trim KitsBrookhaven Direct Vent Gas Fireplace Brookhaven Direct Vent Gas Fireplace Brookhaven Direct Vent Gas Fireplace If Warranty Service is NEEDED… Product Covered by this WarrantyAFUE% Efficiency Ratings