Vermont Casting 20DVT Framing and Finishing, Final Finishing, Gas Specifications, High Elevations

Page 6

Brookhaven Direct Vent Gas Fireplace

Framing and Finishing

Check fireplace to make sure it is levelled and properly positioned.

To mount the appliance:

1.Choose the location.

2.This unit comes with four (4) flanges pre-mounted on both sides of the fireplace to allow two different drywall thicknesses to be used. Flange “A” is for 1/2” drywall while flange “B” is for 5/8” drywall.

3.Bend the desired flanges out 90° on both sides of the fireplace. Slide the fireplace into the framed opening until the flanges contact the front surfaces of the framing. Level the unit and secure it firmly in place.

Flange

Drywall

Flange Location for

Position

Depth

Desired Drywall Depth

A

1/2” / 13 mm

 

B

5/8” / 16 mm

 

AB

FP1539

Fig. 4 Nailing flanges.

Final Finishing

Noncombustible materials such as brick or tile may be extended over the edges of the face of the fireplace. DO NOT cover any vent or grille panels.

If a Trim Kit is going to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the fireplace.

20DVT

Certified To

ANSI Z21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heaters

Unit: GFDN4B0

Gas Specifications

 

 

 

 

 

Max.

Min.

Air

 

 

 

 

 

Input

Input

Shutter

Model

Fuel

Gas Control

BTU/h

BTU/h

Setting

 

 

 

 

 

 

 

 

Sides &

20DVTRN

Nat.

Millivolt Hi/Lo

13,000

8,700

Bottom

 

 

 

 

 

 

 

 

Half Open

 

 

 

 

 

 

 

 

Sides &

20DVTRP

Prop.

Millivolt Hi/Lo

13,000

8,700

Bottom

 

 

 

 

 

 

 

 

Half Open

 

 

 

 

 

 

 

 

 

Gas Inlet and Manifold Pressures

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural

 

LP (Propane)

Inlet Minimum

 

 

5.5” w.c.

 

11.0” w.c.

Inlet Maximum

 

 

14.0” w.c.

 

14.0” w.c.

Manifold Pressure

3.5” w.c.

 

10.0” w.c.

 

 

 

 

 

 

 

 

 

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.

For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the cur- rent ANSI Z223.1/NFPA 54 and/or local codes hav- ing jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).

Gas Line Installation

When purging the gas lines, the front win- dow frame assembly must be removed.

The gas pipeline can be brought in through the rear of the appliance as well as the bottom. Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection. It is most convenient to bring the gas line in from the rear right side of the valve as this allows fan installation or removal without disconnecting the gas line.

The gas line connection can be made with properly tinned 3/8” copper tubing, 3/8” rigid pipe or an ap- proved flex connector. Since some municipalities have additional local codes, it is always best to consult your local authority and the National Fuel Gas Code, ANSI Z223.1/NFPA 54 in the USA or the CSA-B149.1 installa- tion code.

Always check for gas leaks with a mild soap and water solution applied with a brush no larger than 1” (25 mm). Never apply soap and water solution with a spray bottle. Do not use an open flame for leak testing.

6

10009459

Image 6
Contents Brookhaven Direct Vent Model 20DVT Table of Contents Installation & Operating Instructions Locating Your FireplacePlease Review the Following Carefully 20DVT Fireplace Dimensions Framing Dimensions20DVT Clearance to Combustibles MantelsHearth Final Finishing Gas Line InstallationFraming and Finishing Gas SpecificationsRemote ON/OFF Switch General VentingLocation of Vent Termination Canadian Installations1 US Installations2 General Venting Information Termination LocationGeneral Information Assembling Vent Pipes Canadian InstallationsUSA Installations Flex Vent PipesVertical Sidewall Applications How to Use the Vent GraphTwist Lock Pipes Example aVertical Sidewall Installation Twist Lock Pipe Total angular variation =Step Always install horizontal venting on a level plane Zero clearance sleeve is only required for combustible wallsVertical Sidewall Installation Flex Vent Pipe Below Grade InstallationsVertical Through-the-Roof Installation Vertical Through-the-Roof ApplicationVenting supports Venting Components Operating Instructions Glass CleaningWindow Frame Assembly Removal Glass InformationLog Installation Installation of LogsLog Identification Chart Logs 20DVTLarge Lava Rock Flame & Temperature AdjustmentFlame Characteristics Inspecting the Venting SystemTo Turn Off Gas To Heater What to do if YOU Smell GASTroubleshooting the Gas Control System SIT Nova 820 Millivolt ValveProceeding Nova SIT820 Valve ConversionBurner Orifice Conversion Pilot Orifice Conversion Maintenance Cleaning the Standing Pilot Control SystemBurner and Burner Compartment Description 8a,b 7a,b20DVT Fuel Conversion KitsCeramic Refractory Panels Optional Accessories AvailableRemote Controls Optional Trim KitsBrookhaven Direct Vent Gas Fireplace Brookhaven Direct Vent Gas Fireplace Brookhaven Direct Vent Gas Fireplace Product Covered by this Warranty If Warranty Service is NEEDED…Efficiency Ratings AFUE%