Vermont Casting 20DVT installation instructions General Venting Information Termination Location

Page 8

Brookhaven Direct Vent Gas Fireplace

General Venting Information - Termination Location

D

E

V

L

B

CFM145a

C

V�����

������

F

V

Operable

 

B

 

INSIDE

 

 

 

 

CORNER DETAIL

 

 

 

 

G

 

 

 

 

 

V

 

 

 

N

A

 

 

H

N

 

 

 

 

 

 

 

B

 

 

 

 

 

V

 

B

V

 

 

Operable

Fixed

 

 

 

 

Closed

 

 

 

 

 

 

 

 

 

 

 

B

M

 

B

V J

X

 

 

V K X

 

A

 

I

 

 

 

 

 

 

V VENT TERMINATION X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED

 

 

 

Canadian Installations1

US Installations2

 

A =

Clearance above grade, veranda, porch,

12” (30cm)

12” (30cm)

 

 

deck, or balcony

 

 

 

B = Clearance to window or door that may be

6” (15cm) for appliances

6” (15cm) for appliances

 

 

opened

< 10,000Btuh (3kW), 12” (30cm)

< 10,000 Btuh (3kW), 9”

 

 

 

for appliances > 10,000 Btuh (3kW) and

(23cm) for appliances > 10,000

 

 

 

< 100,000 Btuh (30kW), 36” (91cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

C = Clearance to permanently closed window

12” (305mm) recommended to

12” (305mm) recommended to

 

 

 

prevent window condensation

prevent window condensation

 

D = Vertical clearance to ventilated soffit located

 

 

 

 

above the terminal within a horizontal

18” (458mm)

18” (458mm)

 

 

distance of 2’ (610mm) from the center

 

 

 

 

line of the terminal

 

 

 

E = Clearance to unventilated soffit

12” (305mm)

12” (305mm)

 

F =

Clearance to outside corner

see next page

see next page

 

G = Clearance to inside corner (see next page)

see next page

see next page

 

H = Clearance to each inside of center line

3’ (91cm) within a height of 15’ (5m)

3’ (91cm) within a height of 15’

 

 

extended above meter/regulator assembly

above the meter/regulator assembly

(5m) above the meter/regulator

 

 

 

 

assy

 

I =

Clearance to service regulator vent outlet

3’ (91cm)

3’ (91cm)

 

J =

Clearance to nonmechanical air supply inlet

6” (15cm) for appliances < 10,000

6” (15cm) for appliances

 

 

to building or the combustion air inlet to any

Btuh (3kW), 12” (30cm) for

< 10,000 Btuh (3kW), 9”

 

 

other appliances

appliances > 10,000 Btuh (3kW) and

(23cm) for appliances > 10,000

 

 

 

< 100,000 Btuh (30kW), 36” (91cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

K = Clearance to a mechanical air supply inlet

6’ (1.83m)

3’ (91cm) above if within 10

 

 

 

 

feet (3m) horizontally

 

L =

Clearance above paved sidewalk or paved

7’ (2.13m)†

7’ (2.13m)†

 

 

driveway located on public property

 

 

 

M = Clearance under veranda, porch, deck or

12” (30cm)‡

12” (30cm)‡

 

 

balcony

 

 

N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450mm).

1 In accordance with the current CSA-B149 Installation Codes

2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes

A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings

‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances.

2.The special venting system used on Direct Vent Fireplaces are certified as part of the appliance, with clearances tested and approved by the listing agency.

3.CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

Fig. 7 Termination location requirements.

8

10009459

Image 8
Contents Brookhaven Direct Vent Model 20DVT Table of Contents Please Review the Following Carefully Installation & Operating InstructionsLocating Your Fireplace 20DVT 20DVT Fireplace DimensionsFraming Dimensions Hearth Clearance to CombustiblesMantels Gas Line Installation Framing and FinishingFinal Finishing Gas SpecificationsLocation of Vent Termination Remote ON/OFF SwitchGeneral Venting Canadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesHow to Use the Vent Graph Twist Lock PipesVertical Sidewall Applications Example aStep Vertical Sidewall Installation Twist Lock PipeTotal angular variation = Always install horizontal venting on a level plane Zero clearance sleeve is only required for combustible wallsVertical Sidewall Installation Flex Vent Pipe Below Grade InstallationsVertical Through-the-Roof Installation Vertical Through-the-Roof ApplicationVenting supports Venting Components Glass Cleaning Window Frame Assembly RemovalOperating Instructions Glass InformationInstallation of Logs Log Identification ChartLog Installation Logs 20DVTFlame & Temperature Adjustment Flame CharacteristicsLarge Lava Rock Inspecting the Venting SystemTo Turn Off Gas To Heater What to do if YOU Smell GASTroubleshooting the Gas Control System SIT Nova 820 Millivolt ValveBurner Orifice Conversion ProceedingNova SIT820 Valve Conversion Pilot Orifice Conversion Burner and Burner Compartment MaintenanceCleaning the Standing Pilot Control System Description 8a,b 7a,b20DVT Fuel Conversion KitsOptional Accessories Available Remote ControlsCeramic Refractory Panels Optional Trim KitsBrookhaven Direct Vent Gas Fireplace Brookhaven Direct Vent Gas Fireplace Brookhaven Direct Vent Gas Fireplace Product Covered by this Warranty If Warranty Service is NEEDED…Efficiency Ratings AFUE%