3.Install the Chimney Connector Starter Pipe. (Not supplied)
•Mark and drill two 5/16”, (8mm) holes 1⁵⁄₈” (41mm) from the lower edge of the pipe. Locate the holes on an axis that will be perpendicular to the fireplace opening when the pipe is installed. (Fig. 6)
1���" (35mm)
Fireplace
Front
FP1097
Fig. 8 Install the threaded rod inside the Starter Pipe (not a supplied item, starter pipe is available from the Chimney Con- nector manufacturer).
•Install the threaded rod (A), into the starter pipe using washers and hex nuts (B,C),on the outside of the pipe. Tighten the nuts, but do not distort the pipe opening. (Fig. 6)
•Secure the starter pipe to the chimney connector. (Fig. 7)
4.Install the Floor Protector. Make sure the floor pro- tector satisfies the requirements discussed on Page 6.
5.Install the Optional Outside Air Adapter. Follow the instructions provided with the kit.
6.Install the Optional Surround Kit. Follow the in- structions provided with the kit.
7.Slide the Firebox into Position. At least two people will be needed to move the firebox. Position the firebox so the flue collar lines up with the connector. Use the leveling screws at the front of the Insert to adjust the level. Route the power cord to the side nearest the power supply and test the fans.
8.Join the Chimney Connector to the Flue Collar.
•Assemble the
•From inside the firebox, reach up through the flue collar and engage the hook over the threaded rod inside the starter pipe. Position the steel bar behind the two tabs within the flue collar and then turn the wing nut clockwise to draw the starter pipe down. (Fig. 7)
9.Connect the Blower power cord to the power supply.
This completes installation of your WinterWarm Small Insert.
Seat the Starter | Starter Pipe | |
Pipe on the two | ||
| ||
tabs inside the flue |
| |
collar |
|
FP1098
Fig. 7 Attach starter pipe to flue collar.
8 | 2000888 |