Vermont Casting 2080 Maintenance, Care of the Porcelain Enamel Surface, Cleaning the Glass

Page 14

WinterWarm Small Insert

Maintenance

Keep Your WinterWarm Small Insert Look-

ing New and Working Its Best

Care of the Cast Iron Surface

An occasional dusting with a dry rag will keep the painted cast iron of your WinterWarm Small Insert look- ing new.

If the paint needs retouching, first allow the surface to cool completely. Mask glass, trim parts and enamelled areas. Wire-brush those areas needing to be painted. Touch-up with high temperature stove paint available from your local dealer. Apply the paint sparingly. Two

light coats are better than one heavy one.

Care of the Porcelain Enamel Surface

Use a soft brush as necessary. Do not use water or other liquids on your WinterWarm Small Insert. Finger- prints usually can be buffed off porcelain enamel with a dry, soft cloth. If marks remain, allow the WinterWarm Small Insert to cool completely, then buff with a slightly damp, soft cloth. Dry completely before starting a fire to avoid streaking.

Never use abrasives or harsh chemical cleaners on the porcelain enamel finish; the enamel may scratch and expose the cast iron, which can then stain or rust. If you must remove spills or stains from porcelain surfac- es, make sure the fire is out and the WinterWarm Small Insert has cooled completely before cleaning. Use a kitchen appliance cleaner and/or polish specially formu- lated for enamel surfaces. Apply the cleaner sparingly

with a soft cloth, and buff away all traces.

Cleaning the Glass

The WinterWarm Small Insert glass system requires a minimum amount of cleaning. Most carbon deposits that accumulate will burn off during hot fires.

Ash residue that accumulates on the glass should be removed periodically to prevent etching. To clean the glass, use the following procedure.

Be sure the glass is completely cool.

Cleaning with water will work in most cases. Use a glass cleaner especially made for this purpose only if deposits are specially heavy. (If heavy deposits are a frequent occurrence, however, evaluate your operating techniques.) Do not use abrasive cleaners.

Rinse the glass thoroughly.

Dry the glass completely.

NOTE: The WinterWarm Small Insert glass is coated with a special material on one side that helps reflect heat back into the fire chamber. Do

not attempt to remove this coating.

Adjust the Door Latch Periodically

The front door of the WinterWarm Small Insert should close securely to prevent accidental opening and should close tightly to prevent air from leaking into the fire chamber. The door handle will be positioned verti- cally when the door is closed.

Over a period of time, the gasket around the door will compress and the latch may need adjustment. To ad- just the handle, follow this procedure:

1.Loosen the small lock nut with a 7/16” wrench. (Fig. 14)

2.Extend the striker screw one turn by turning it with a 1/8” Allen wrench.

3.Re-tighten the lock nut, while at the same time hold- ing the striker screw with the Allen wrench to prevent its turning.

Pawl

Small

Locking Nut

Striker Screw

Large

Locking

Nut

Set Screw

Handle Stub

ST531

 

Fig. 14 Turn the door latch striker screw in or out to tighten or loosen the door latch.

Test the door seal. Close the door on a dollar bill and attempt to pull it free. If the bill is freed with little re- sistance, the gasket isn’t snug enough at that spot. Continue to make small adjustments until the setting is right.

If additional adjusting of the latch does not enable the door to seal sufficiently in one area, try “adjusting” the gasket in that area. Pack more cement or a smaller diameter gasket into the channel beneath the gasket so the main gasket is raised and makes contact with the door frame. If this procedure doesn’t solve the problem, replace the gasket. Instructions for gasket replacement are given later in this section.

14

2000888

Image 14
Contents Winter Warm Table of Contents IntroductionSpecifications WinterWarm Small InsertRequirements for Existing Chimneys InstallationRequirements for Existing Fireplaces Chimney Height / U.S. and CanadaGeneral Considerations / U.S Minimum Fireplace DimensionsWhen the insert is installed in a factory-built fire- place Sealing Requirements / U.SClearance Requirements Hearth RequirementsInstalling the WinterWarm Small Insert Optional Surround PackagesInstall the Chimney Connector Starter Pipe. Not supplied Connect the Blower power cord to the power supplyDamper OperationYour WinterWarm Insert’s Controls and What They Do Primary Air ControlFans Use the Air Control Settings that Work Best for YouWinterWarm Small Insert Control Settings Burn Only High-Quality WoodStarting and Maintaining a Wood Fire How To Build and Sustain a Wood FireHigh-Efficiency Wood Burning with Catalytic Combustion Do not over-fire this heater Reloading and Reviving a Wood FireSpecial Tactics for Cold-Climate Heating Remove and Store Ash Safely Adjust the Door Latch Periodically MaintenanceCleaning the Glass Care of the Porcelain Enamel SurfaceAdjust the Damper as Needed Removing and Replacing Door GlassReplaceable WinterWarm Small Insert Fiberglass Gaskets How to Replace GasketsReplacing the Insert’s Door Gaskets Removal and Inspection of the Combustor Refractory Package When To Suspect a Combustor ProblemCare of the Catalytic Combustor Learn To Recognize Avoid Creosote Chimney System Clean Chimney System is Safer Works BetterWatch for Better Results Flex Connection Fireplace System Maintenance ScheduleFireplace Appendix Catalytic Combustor WinterWarm Small Insert Model WinterWarm Small Insert Warranty CFM Corporation