Empire Comfort Systems BVP42FP52, L)N-1, BVD34FP50, BVP42FP32 Maintenance and Service, Please Note

Page 27

MAINTENANCE AND SERVICE

PLEASE NOTE

It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.

It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.

Please ensure that your room is well ventilated - open all windows.

It is recommended that you burn your fireplace for at least six

(6)hours the first time you use it. If optional fan kit has been installed, place fan in the “OFF” position during this time.

IMPORTANT: Turn off gas before servicing appliance. It is recommended that a qualified service person perform these check-ups at the beginning of each heating season.

Clean Burner and Control Compartment

Keepthecontrolcompartment,logs,andburnerareassurrounding the logs clean by vacuuming or brushing at least twice a year.

Cleaning Procedure

1.Turn off pilot light at gas valve.

2.Vacuum burner compartment.

3.Ignite pilot (if applicable). (See Lighting Instructions)

4.Operate the pilot burner (if applicable). If it appears abnormal call a service person.

Check Vent System

The appliance and venting system should be inspected before initial use and at least annually by a qualified service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the air flow.

Glass Cleaning (Optional Kits)

It will be necessary to clean the glass periodically. During start-up condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non-abrasive household cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depending on the circumstances present.

General Glass Information

Only glass approved for use by the manufacturer may be used for replacement. The glass replacement should be done by a licensed or qualified service person.

WARNING:

1.The use of substitute glass will void all product warranties.

2.Care must be taken to avoid breakage of glass.

3.Do not abuse the glass by striking or hitting the glass.

WARNING: Do not use abrasive cleaners on glass. Do not attempt to clean glass when glass is hot.

19400-3-0406

Page 27

Image 27
Contents Installation Instructions Table of Contents Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP GASIntroduction Fireplace Dimensions SpecificationsCombustible Material Mantel Chart FigureClearances Locating FireplaceGAS Supply Installing a New Main Gas CockGAS Line Hole Checking Manifold PressuresFraming Figure InstallationVent Pipe Clearance Install the Fresh Air Kit BVA1 Framing and FinishingFinishing Figure Combustible Surround InstallationVent Runs General MaintenanceInstalling the Vent System in a Chase VentingVent Size Never downsize venting diameters ClearancesVent Configuration Offset Venting With Elbows Ember Material Placement on Burner LOG Placement 5 LOG SETLOG Placement 3 LOG SET Pilot Flame Figure Operating InstructionsMillivolt System Initial LightingMillivolt Control Wall Switch, FWS-1 optionalFrbc Battery Operated Remote Control Standing Pilot Operating InstructionsStanding Pilot Wiring Diagram What to do if YOU Smell GAS Standing Pilot Lighting InstructionsPilot and main burner extinguish while in operation Standing Pilot TroubleshootingFrequent pilot outage problem Pilot burning, no gas to burner, valve knob onStanding Pilot PROPANE/LP GAS Conversion Pilot Orifice Conversion Optional Remote Control 120V Direct Ignition Direct Ignition Wiring DiagramDirect Ignition Lighting Instructions For Your Safety Read Before LightingDirect Ignition PROPANE/LP GAS Conversion Direct Ignition TroubleshootingMaxitrol Valve Conversion Please Note Maintenance and ServiceBrick PANEL, Painted BVD34 & BVD36 Parts ListBVD34 & BVD36 Parts View Flex LINE/SHUTOFF Valve BVP42 Parts ListBVP42 Parts View FBB4 Optional Variable Speed Blower Installation Volt AC Standard Millivolt Valve Models Junction BOX Wiring Installation InstructionsBVA1 Optional AccessoriesDecorative Louver Mission Decorative Louver Arch Decorative AccessoriesService Notes HOW to Order Repair Parts Service Notes Service Notes

BVD34FP50, BVP42FP52, BVP42FP32, BVD34FP30, BVD36FP52 specifications

Empire Comfort Systems has carved a niche in the heating industry with its series of high-quality ventless gas fireplaces. Among their popular models are the BVD34FP50, BVD34FP30, BVD36FP52, BVP42FP52, and BVP42FP32. Each of these units combines sophisticated design with innovative technology, offering home comfort and style.

The BVD34FP50 and BVD34FP30 are known for their sleek appearance and efficient performance. These models feature a minimalist design that allows them to blend seamlessly into any room decor. The BVD34FP50 is equipped with a powerful 50,000 BTU output, making it ideal for larger areas. Conversely, the BVD34FP30, with its 30,000 BTU output, offers an energy-efficient heating solution for smaller spaces. Both models utilize Empire's advanced vent-free technology, which allows for easy installation without the need for traditional venting.

The BVD36FP52 stands out for its versatility in design and efficiency. With a 52,000 BTU capacity, it heats larger spaces effectively while maintaining a sleek and modern visible flame. This model also benefits from an adjustable flame feature, allowing users to customize the intensity to their liking. Its superior ceramic glass front provides excellent heat retention and delivers an unobstructed view of the mesmerizing flames, enhancing any living space.

Empire's BVP42FP52 and BVP42FP32 models further exemplify the brand’s commitment to innovation. The BVP42FP52 offers a robust heating capacity of 52,000 BTUs, while the BVP42FP32 delivers 32,000 BTUs, making both units adaptable for varying room sizes. These models are distinguished by their high-efficiency ceramic glass doors and programmable thermostats, allowing for precise temperature control.

All models are designed with user-friendly features such as remote control options, adjustable flame height, and safety shut-off mechanisms. Additionally, their contemporary aesthetics make them suitable for modern and traditional homes alike. Empire Comfort Systems ensures top-tier reliability and performance, making these fireplaces a worthy investment for all who seek warmth and elegance in their living spaces.