Empire Comfort Systems BVD34FP30, L)N-1, BVD34FP50 Important Safety Information, Appliance

Page 3

IMPORTANT SAFETY INFORMATION

Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly.

If this appliance is installed directly on carpeting,

Clothing or other flammable material should not be

 

tile or other combustible material other than wood

 

placed on or near the appliance.

 

flooring the appliance shall be installed on a metal or

Adequate accessibility clearances for servicing and

 

wood panel extending the full width and depth of the

 

 

proper operation.

 

appliance.

 

 

This appliance must not share or be connected to a

 

The base referred to above does not mean the fireproof

 

 

flue serving a separate solid-fuel burning appliance.

 

base as used on wood stoves. The protection is for rugs

 

 

Keep the area around your appliance clear of

 

that are extremely thick and light colored tile.

Children and adults should be alerted to the hazards

 

combustible materials, gasoline and other flammable

 

vapor and liquids.

 

of high surface temperatures and should stay away

 

 

Under no circumstances should any solid fuels

 

to avoid burns or clothing ignition.

Young children should be carefully supervised when

 

(wood, coal, paper or cardboard etc.) be used in this

 

appliance.

 

they are in the same room as the appliance.

 

 

 

 

• The flow of combustion and ventilation air must not be obstructed in any way.

Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies.

Any part removed for servicing the appliance must be replaced prior to operating the appliance. Work should be done by a qualified service person.

Keep burner and control compartment clean.

Vent cap is hot while fireplace is in operation.

Installation and repair should be done by a QUALIFIED SERVICE PERSON. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.

DO NOT put anything around the fireplace that will obstruct the flow of ventilation air.

Clearance in accordance with local installation codes and the requirements of the gas supplier.

DO keep the appliance area clear and free from combustiblematerial,gasolineandotherflammable vapors and liquids.

DO examine venting system periodically and replace damaged parts.

DO make a periodic visual check of pilot and burners. Clean and replace damaged parts.

DO NOT use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.

19400-3-0406

Page 3

Image 3
Contents Installation Instructions Table of Contents Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP GASIntroduction Fireplace Dimensions SpecificationsCombustible Material Mantel Chart FigureClearances Locating FireplaceGAS Supply Installing a New Main Gas CockGAS Line Hole Checking Manifold PressuresFraming Figure InstallationVent Pipe Clearance Install the Fresh Air Kit BVA1 Framing and FinishingFinishing Figure Combustible Surround InstallationVent Runs General MaintenanceInstalling the Vent System in a Chase VentingVent Size Never downsize venting diameters ClearancesVent Configuration Offset Venting With Elbows Ember Material Placement on Burner LOG Placement 5 LOG SETLOG Placement 3 LOG SET Pilot Flame Figure Operating InstructionsMillivolt System Initial LightingMillivolt Control Wall Switch, FWS-1 optionalFrbc Battery Operated Remote Control Standing Pilot Operating InstructionsStanding Pilot Wiring Diagram What to do if YOU Smell GAS Standing Pilot Lighting InstructionsPilot and main burner extinguish while in operation Standing Pilot TroubleshootingFrequent pilot outage problem Pilot burning, no gas to burner, valve knob onStanding Pilot PROPANE/LP GAS Conversion Pilot Orifice Conversion Optional Remote Control 120V Direct Ignition Direct Ignition Wiring DiagramDirect Ignition Lighting Instructions For Your Safety Read Before LightingDirect Ignition PROPANE/LP GAS Conversion Direct Ignition TroubleshootingMaxitrol Valve Conversion Please Note Maintenance and ServiceBrick PANEL, Painted BVD34 & BVD36 Parts ListBVD34 & BVD36 Parts View Flex LINE/SHUTOFF Valve BVP42 Parts ListBVP42 Parts View FBB4 Optional Variable Speed Blower Installation Volt AC Standard Millivolt Valve Models Junction BOX Wiring Installation InstructionsBVA1 Optional AccessoriesDecorative Louver Mission Decorative Louver Arch Decorative AccessoriesService Notes HOW to Order Repair Parts Service Notes Service Notes

BVD34FP50, BVP42FP52, BVP42FP32, BVD34FP30, BVD36FP52 specifications

Empire Comfort Systems has carved a niche in the heating industry with its series of high-quality ventless gas fireplaces. Among their popular models are the BVD34FP50, BVD34FP30, BVD36FP52, BVP42FP52, and BVP42FP32. Each of these units combines sophisticated design with innovative technology, offering home comfort and style.

The BVD34FP50 and BVD34FP30 are known for their sleek appearance and efficient performance. These models feature a minimalist design that allows them to blend seamlessly into any room decor. The BVD34FP50 is equipped with a powerful 50,000 BTU output, making it ideal for larger areas. Conversely, the BVD34FP30, with its 30,000 BTU output, offers an energy-efficient heating solution for smaller spaces. Both models utilize Empire's advanced vent-free technology, which allows for easy installation without the need for traditional venting.

The BVD36FP52 stands out for its versatility in design and efficiency. With a 52,000 BTU capacity, it heats larger spaces effectively while maintaining a sleek and modern visible flame. This model also benefits from an adjustable flame feature, allowing users to customize the intensity to their liking. Its superior ceramic glass front provides excellent heat retention and delivers an unobstructed view of the mesmerizing flames, enhancing any living space.

Empire's BVP42FP52 and BVP42FP32 models further exemplify the brand’s commitment to innovation. The BVP42FP52 offers a robust heating capacity of 52,000 BTUs, while the BVP42FP32 delivers 32,000 BTUs, making both units adaptable for varying room sizes. These models are distinguished by their high-efficiency ceramic glass doors and programmable thermostats, allowing for precise temperature control.

All models are designed with user-friendly features such as remote control options, adjustable flame height, and safety shut-off mechanisms. Additionally, their contemporary aesthetics make them suitable for modern and traditional homes alike. Empire Comfort Systems ensures top-tier reliability and performance, making these fireplaces a worthy investment for all who seek warmth and elegance in their living spaces.