Empire Comfort Systems BVD36FP32 Safety Information for Users of LP GAS, LP-GAS Warning Odor

Page 4

SAFETY INFORMATION FOR USERS OF LP GAS

Propane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precautions which can protect both you and your family from an accident. Read them carefully now, then review

them point by point with the members of your household. Someday when there may not be a minute to lose, everyone’s safety will depend on knowing exactly what to do. If, after reading the following information, you feel you still need more information, please contact your gas supplier.

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas.

That’s your signal to go into immediate action!

Do not operate electric switches, light matches, use your phone. Do not do anything that could ignite the gas.

Get everyone out of the building, vehicle, trailer, or area. Do that IMMEDIATELY.

Close all gas tank or cylinder supply valves.

LP-Gas is heavier than air and may settle in low areas such as basements. When you have reason to suspect a gas leak, keep out of basements and other low areas. Stay out until firefighters declare them to be safe.

Use your neighbor’s phone and call a trained LP-Gas service person and the fire department. Even though you may not continue to smell gas, do not turn on the gas again. Do not re-enter the building, vehicle, trailer, or area.

Finally, let the service man and firefighters check for escaped gas. Have them air out the area before you return. Properly trained LP-Gas service people should repair the leak, then check and relight the gas appliance for you.

NO ODOR DETECTED - ODOR FADE

Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Sometimes other odors in the area mask the gas odor. People may not smell the gas odor or their minds are on something else. Thinking about smelling a gas odor can make it easier to smell.

The odorant in LP-Gas is colorless, and it can fade under some circumstances. For example, if there is an underground leak, the movement of the gas through soil can filter the odorant. Odorants in LP-Gas also are subject to oxidation. This fading

can occur if there is rust inside the storage tank or in iron gas pipes.

The odorant in escaped gas can adsorb or absorb onto or into walls, masonry and other materials and fabrics in a room. That will take some of the odorant out of the gas, reducing its odor intensity.

LP-Gas may stratify in a closed area, and the odor intensity could vary at different levels. Since it is heavier than air, there may be more odor at lower levels. Always be sensitive to the slightest gas odor. If you detect any odor, treat it as a serious leak. Immediately go into action as instructed earlier.

SOME POINTS TO REMEMBER

Learn to recognize the odor of LP-Gas. Your local LP-Gas Dealer can give you a “Scratch and Sniff” pamphlet. Use it to find out what the propane odor smells like. If you suspect that your LP-Gas has a weak or abnormal odor, call your LP-Gas Dealer.

If you are not qualified, do not light pilot lights, perform service, or make adjustments to appliances on the LP-Gas system. If you are qualified, consciously think about the odor of LP-Gas prior to and while lighting pilot lights or performing service or making adjustments.

Sometimes a basement or a closed-up house has a musty smell that can cover up the LP-Gas odor. Do not try to light pilot lights, perform service, or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP-Gas.

Odor fade, due to oxidation by rust or adsorption on walls of new cylinders and tanks, is possible. Therefore, people should be particularly alert and careful when new tanks or cylinders are placed in service. Odor fade can occur in new tanks, or reinstalled old tanks, if they are filled and allowed

to set too long before refilling. Cylinders and tanks which have been out of service for a time may develop internal rust which will cause odor fade. If such conditions are suspected to exist, a periodic sniff test of the gas is advisable. If you have any question about the gas odor, call your LP-Gas dealer. A periodic sniff test of the LP-Gas is a good safety measure under any condition.

If, at any time, you do not smell the LP-Gas odorant and you think you should, assume you have a leak. Then take the same immediate action recommended above for the occasion when you do detect the odorized LP-Gas.

If you experience a complete “gas out,” (the container is under no vapor pressure), turn the tank valve off immediately. If the container valve is left on, the container may draw in some air through openings such as pilot light orifices. If this occurs, some new internal rusting could occur. If the valve is left open, then treat the container as a new tank. Always be sure your container is under vapor pressure by turning it off at the container before it goes completely empty or having it refilled before it is completely empty.

Page 4

19400-3-0406

Image 4
Contents Installation Instructions Table of Contents Important Safety Information ApplianceSafety Information for Users of LP GAS LP-GAS Warning OdorIntroduction Specifications Fireplace DimensionsMantel Chart Figure ClearancesLocating Fireplace Combustible MaterialInstalling a New Main Gas Cock GAS SupplyChecking Manifold Pressures GAS Line HoleInstallation Vent Pipe Clearance Install the Fresh Air Kit BVA1Framing and Finishing Framing FigureCombustible Surround Installation Finishing FigureGeneral Maintenance Installing the Vent System in a ChaseVenting Vent RunsNever downsize venting diameters Clearances Vent SizeVent Configuration Offset Venting With Elbows LOG Placement 5 LOG SET Ember Material Placement on BurnerLOG Placement 3 LOG SET Operating Instructions Millivolt SystemInitial Lighting Pilot Flame FigureWall Switch, FWS-1 optional Frbc Battery Operated Remote ControlStanding Pilot Operating Instructions Millivolt ControlStanding Pilot Wiring Diagram Standing Pilot Lighting Instructions What to do if YOU Smell GASStanding Pilot Troubleshooting Frequent pilot outage problemPilot burning, no gas to burner, valve knob on Pilot and main burner extinguish while in operationStanding Pilot PROPANE/LP GAS Conversion Pilot Orifice Conversion Direct Ignition Wiring Diagram Optional Remote Control 120V Direct IgnitionFor Your Safety Read Before Lighting Direct Ignition Lighting InstructionsDirect Ignition Troubleshooting Direct Ignition PROPANE/LP GAS ConversionMaxitrol Valve Conversion Maintenance and Service Please NoteBVD34 & BVD36 Parts List Brick PANEL, PaintedBVD34 & BVD36 Parts View BVP42 Parts List Flex LINE/SHUTOFF ValveBVP42 Parts View FBB4 Optional Variable Speed Blower Installation Volt AC Junction BOX Wiring Installation Instructions Standard Millivolt Valve ModelsOptional Accessories BVA1Decorative Accessories Decorative Louver Mission Decorative Louver ArchService Notes HOW to Order Repair Parts Service Notes Service Notes

BVD34FP50, BVP42FP52, BVP42FP32, BVD34FP30, BVD36FP52 specifications

Empire Comfort Systems has carved a niche in the heating industry with its series of high-quality ventless gas fireplaces. Among their popular models are the BVD34FP50, BVD34FP30, BVD36FP52, BVP42FP52, and BVP42FP32. Each of these units combines sophisticated design with innovative technology, offering home comfort and style.

The BVD34FP50 and BVD34FP30 are known for their sleek appearance and efficient performance. These models feature a minimalist design that allows them to blend seamlessly into any room decor. The BVD34FP50 is equipped with a powerful 50,000 BTU output, making it ideal for larger areas. Conversely, the BVD34FP30, with its 30,000 BTU output, offers an energy-efficient heating solution for smaller spaces. Both models utilize Empire's advanced vent-free technology, which allows for easy installation without the need for traditional venting.

The BVD36FP52 stands out for its versatility in design and efficiency. With a 52,000 BTU capacity, it heats larger spaces effectively while maintaining a sleek and modern visible flame. This model also benefits from an adjustable flame feature, allowing users to customize the intensity to their liking. Its superior ceramic glass front provides excellent heat retention and delivers an unobstructed view of the mesmerizing flames, enhancing any living space.

Empire's BVP42FP52 and BVP42FP32 models further exemplify the brand’s commitment to innovation. The BVP42FP52 offers a robust heating capacity of 52,000 BTUs, while the BVP42FP32 delivers 32,000 BTUs, making both units adaptable for varying room sizes. These models are distinguished by their high-efficiency ceramic glass doors and programmable thermostats, allowing for precise temperature control.

All models are designed with user-friendly features such as remote control options, adjustable flame height, and safety shut-off mechanisms. Additionally, their contemporary aesthetics make them suitable for modern and traditional homes alike. Empire Comfort Systems ensures top-tier reliability and performance, making these fireplaces a worthy investment for all who seek warmth and elegance in their living spaces.