Empire Comfort Systems CHBR-16-3 installation instructions CHBR-16 Lighting Instructions

Page 13

CHBR-16 LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result caus-

ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire

department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

Note: For easy access to valve for lighting pilot, remove branch log and middle log from burner assembly before lighting.

1.STOP! Read the safety information label.

2.Make sure the manual shutoff valve is fully open.

3.This gas log set is equipped with an ignition device (piezo) which lights the pilot. If piezo ignitor does not light the pilot, refer to Step 7.

4.Turn gas control knob clockwise to the “OFF” position, set the thermostat to the lowest setting and turn ON/OFF switch to OFF position.

5.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP! Follow “B” in the safety information label. If you do not smell gas, go to the next step.

6.From OFF position, turn the gas control knob counterclock-

wise to “Pilot” position. Push in and hold control knob for 5 seconds.

7.With the control knob pushed in, repeatedly push the piezo ignitor button until pilot is lit (or use a match to light pi- lot).

8.Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting off the gas while the probe is warming up. Release the control knob.

9.Turn gas control knob counterclockwise to the “ON” position.

10.After the pilot has been lit for one minute, the burner can be turned on. Turn the ON/OFF switch to “ON” position or adjust thermostat to desired setting.

11.If the gas logs will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier.

Wait 30 seconds before readjusting the heater when the control knob has been turned down to a lower setting.

PIEZO

IGNITOR

HI/LO

REGULATOR

CONTROL

KNOB

TO TURN OFF GAS TO APPLIANCE

1. Turn control knob clockwise

to OFF position to

2. If applicable: Turn ON/OFF switch to OFF position and/or

completely shut off the heater.

 

set thermostat (if present) to lowest setting. If applicable:

 

 

Turn off all electric power to the heater.

16934-3-0806

Page 13

Image 13
Contents Installation Instructions Table of Contents Do not Tamper with Pilot Light Safety System Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsProduct Description Well Head Gas Installations Installation on Rugs and TileGeneral Information Before you get startedUnusually Tight Construction Provisions for Adequate Combustion & Ventilation AIRClearances Pressure Testing of the Gas Supply System Installing a New Main Gas CockGAS Supply Recommended Gas Pipe DiameterSET-UP Instructions Placement of Glowing Embers and Lava Rock Thermostat Operation Operation INSTRUCTIONS/FLAME AppearanceCHBR-16 Lighting Instructions For Your Safety Read Before LightingCleaning and Maintenance/Pilot Pilot Flame CharacteristicsTurn OFF Heater and Allow to Cool Before Cleaning Cleaning and ServicingControl Panel Installation WiringCheck System Operation Millivolt SystemHeater produces a whistling noise when main burner is lit Gas odor even when control knob is in OFF positionAppliance produces unwanted odors Appliance shuts off during use. Pilot stays onHOW to Order Repair Parts Parts ListParts View Service Notes

CHBR-16-3 specifications

Empire Comfort Systems CHBR-16-3 is a premier choice for heating solutions, particularly favored for its combination of efficiency and convenience. This model is designed to meet the heating needs of various spaces, from homes to commercial settings, ensuring warmth and comfort even in the coldest winter months.

One of the standout features of the CHBR-16-3 is its impressive heating capacity. With an output of up to 16,000 BTUs, this unit can efficiently heat large areas, making it ideal for living rooms, basements, or even open floor plans. The powerful heat output is further complemented by a thermally efficient design, allowing the unit to operate effectively while keeping energy consumption low.

The CHBR-16-3 utilizes advanced technologies to maintain consistent temperatures. Its built-in blower system ensures an even distribution of heat throughout the space, eliminating cold spots and creating a comfortable environment. This feature is particularly beneficial in larger areas where heat can often be unevenly distributed.

Installation and ease of use are also highlights of this model. The unit is designed for straightforward installation and can be integrated into existing heating systems with relative ease. Additionally, it is equipped with a user-friendly manual control, giving users the ability to adjust settings according to their preferences. Optional remote control capabilities are also available, allowing for added convenience, especially during colder weather.

Safety is another crucial aspect of the CHBR-16-3. The unit is designed with multiple safety features, including an automatic shut-off to prevent overheating and a sealed burner to reduce the risk of carbon monoxide exposure. This attention to safety ensures peace of mind for users, allowing them to enjoy the warmth without worry.

Durability is a hallmark of Empire Comfort Systems products, and the CHBR-16-3 is no exception. Constructed from high-quality materials, this heater is designed to withstand the rigors of regular use. With proper maintenance, users can expect a long lifespan from this heating appliance.

In summary, the Empire Comfort Systems CHBR-16-3 is an excellent heating solution that stands out for its efficiency, user-friendly features, safety measures, and durable construction. Whether for residential or commercial use, this model provides reliable warmth that enhances comfort during the cold months.