Empire Comfort Systems CHBR-16-3 installation instructions SET-UP Instructions

Page 10

SET-UP INSTRUCTIONS

Attention: Two people are required to assemble indoor chimenea.

1.Remove packing material from top of box.

2.Lift stack casting section out and set aside.

3.Remove remaining items and packing from inside body casting.

4.Lift body casting out of box and sit on flat surface near desired final location. Leave adequate room around body casting to work. Locking ring for stack casting should be facing down. Two people are required to remove casting from shipping carton.

5.Remove washers and nuts from three legs. Install the three legs using the bolts, washers and nuts provided. Reach through the opening in the body casting to tighten the leg bolts securely. See Figure 4.

Figure 4

6.Remove the bottom block off plate from stack casting. The bottom block off plate is a half-moon shaped, 11 inch length, black metal plate located within the stack casting.

7.Place bottom block off plate onto exterior, bottom of body casting. Align clearance holes in bottom block off plate with bolt holes in body casting.

8.Place a lock washer followed by a flat washer onto 3/8 inch bolt. You will need to use three (3) 3/8 inch bolts to attach bottom block off plate to body casting.

Attention: Start each bolt partially into body casting in order to properly align bolts for attachment of bottom block off plate to body casting.

9.Invert the body casting to sit on its legs.

10. Holding the burner support plate securely with two hands, tip the burner assembly to a position where it will fit through the front door opening. Guide the gas valve through the large hole in the bottom of the body casting. The burner support plate will come to rest on the three flat mounting tabs that protrude from the body casting wall and the gas valve should be approximately centered between the left leg and the right leg.

11. Align clearance hole on burner support plate with threaded hole in front of flat mounting tab. Attach burner support plate to mounting tab with one (1) 1/4-20 x 3/8" screw. Install (2) 3-1/2" bolts through burner support bottom, casting bottom and block off plate and secure with (2) nuts.

12. One (1) keyhole will be adjacent to front side (opening) on body casting. Two (2) keyholes will be adjacent to back side

Page 10

(rear) on body casting. Attention: If the keyhole positions are reversed on body casting DO NOT attempt to operate the indoor chimenea. An unsafe overheating condition of the wall could occur. Contact your qualified serviceman or dealer for replacement parts. See Figure 5.

Figure 5

13.Located on bottom of stack casting are three securing bolts. Unscrew securing bolts approximately 1/2".Attention: Do not remove securing bolts from bottom of stack casting. Place the stack casting on top of the body casting aligning the three securing bolts on the stack casting with the large end of the "keyhole" slots on the securing ring. Once the stack casting is in place, twist to lock it down. See Figure 6.

14. To install door screen, hook top of door screen onto body casting. Raise door screen upward. Pivot bottom of door screen inward to hook bottom of door screen, and then lower screen. Do not operate without screen properly installed.

Figure 6

16934-3-0806

Image 10
Contents Installation Instructions Table of Contents Important Safety Information Do not Tamper with Pilot Light Safety SystemSafety Information for Users of LP-GAS LP-GAS Warning OdorIntroduction SpecificationsProduct Description General Information Installation on Rugs and TileWell Head Gas Installations Before you get startedProvisions for Adequate Combustion & Ventilation AIR Unusually Tight ConstructionClearances GAS Supply Installing a New Main Gas CockPressure Testing of the Gas Supply System Recommended Gas Pipe DiameterSET-UP Instructions Placement of Glowing Embers and Lava Rock Operation INSTRUCTIONS/FLAME Appearance Thermostat OperationFor Your Safety Read Before Lighting CHBR-16 Lighting InstructionsPilot Flame Characteristics Cleaning and Maintenance/PilotCleaning and Servicing Turn OFF Heater and Allow to Cool Before CleaningCheck System Operation WiringControl Panel Installation Millivolt SystemAppliance produces unwanted odors Gas odor even when control knob is in OFF positionHeater produces a whistling noise when main burner is lit Appliance shuts off during use. Pilot stays onParts List HOW to Order Repair PartsParts View Service Notes

CHBR-16-3 specifications

Empire Comfort Systems CHBR-16-3 is a premier choice for heating solutions, particularly favored for its combination of efficiency and convenience. This model is designed to meet the heating needs of various spaces, from homes to commercial settings, ensuring warmth and comfort even in the coldest winter months.

One of the standout features of the CHBR-16-3 is its impressive heating capacity. With an output of up to 16,000 BTUs, this unit can efficiently heat large areas, making it ideal for living rooms, basements, or even open floor plans. The powerful heat output is further complemented by a thermally efficient design, allowing the unit to operate effectively while keeping energy consumption low.

The CHBR-16-3 utilizes advanced technologies to maintain consistent temperatures. Its built-in blower system ensures an even distribution of heat throughout the space, eliminating cold spots and creating a comfortable environment. This feature is particularly beneficial in larger areas where heat can often be unevenly distributed.

Installation and ease of use are also highlights of this model. The unit is designed for straightforward installation and can be integrated into existing heating systems with relative ease. Additionally, it is equipped with a user-friendly manual control, giving users the ability to adjust settings according to their preferences. Optional remote control capabilities are also available, allowing for added convenience, especially during colder weather.

Safety is another crucial aspect of the CHBR-16-3. The unit is designed with multiple safety features, including an automatic shut-off to prevent overheating and a sealed burner to reduce the risk of carbon monoxide exposure. This attention to safety ensures peace of mind for users, allowing them to enjoy the warmth without worry.

Durability is a hallmark of Empire Comfort Systems products, and the CHBR-16-3 is no exception. Constructed from high-quality materials, this heater is designed to withstand the rigors of regular use. With proper maintenance, users can expect a long lifespan from this heating appliance.

In summary, the Empire Comfort Systems CHBR-16-3 is an excellent heating solution that stands out for its efficiency, user-friendly features, safety measures, and durable construction. Whether for residential or commercial use, this model provides reliable warmth that enhances comfort during the cold months.