INTRODUCTION

IMPORTANT: Read all instructions carefully before starting installation. Failure to follow these installation instructions may result in a possible fire hazard and will void the warranty.

Save this manual for future reference.

Please read this manual before installing and using the appliance.

Instructions to Installer

1.Installer must leave instruction manual with owner after installation.

2.Installer must have owner fill out and mail warranty card supplied with unvented room heater.

3.Installer should show owner how to start and operate unvented room heater.

Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

In the State of Massachusetts the CHBR-16 must be secured to the floor.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1.*

*Available from the American National Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10018.

Manifold Pressure

Natural Gas

 

Propan Gas

 

Regulator pressure setting

3.5" W.C.

Regulator pressure setting

10.0" W.C.

Gas inlet pressure

Max. 10.5" W.C.

Gas inlet pressure

Max 13.0" W.C.

 

Min. 5.0" W.C.

 

Min. 11.0" W.C.

SPECIFICATIONS

Model

CHBR-16

Input Maximum Btu/Hr

20,000

Minimum Btu/Hr

14,000

Height

49"

Width

23"

Gas Inlet

3/8"

 

ACCESSORIES

Product

Description

No.

 

CHG-VF

Antique Green Chimenea

CHR-VF

Terra Cotta Red Chimenea

FRBC-1

Battery Operated Remote Control

FRBTC-1

Battery Operated Remote Control with Thermo-

 

stat

FREC-1

Electri Remote Control

FWS-1

Wall Switch

16934-3-0806

Page 5

Image 5
Contents Installation Instructions Table of Contents Do not Tamper with Pilot Light Safety System Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASProduct Description SpecificationsIntroduction Well Head Gas Installations Installation on Rugs and TileGeneral Information Before you get startedUnusually Tight Construction Provisions for Adequate Combustion & Ventilation AIRClearances Pressure Testing of the Gas Supply System Installing a New Main Gas CockGAS Supply Recommended Gas Pipe DiameterSET-UP Instructions Placement of Glowing Embers and Lava Rock Thermostat Operation Operation INSTRUCTIONS/FLAME AppearanceCHBR-16 Lighting Instructions For Your Safety Read Before LightingCleaning and Maintenance/Pilot Pilot Flame CharacteristicsTurn OFF Heater and Allow to Cool Before Cleaning Cleaning and ServicingControl Panel Installation WiringCheck System Operation Millivolt SystemHeater produces a whistling noise when main burner is lit Gas odor even when control knob is in OFF positionAppliance produces unwanted odors Appliance shuts off during use. Pilot stays onHOW to Order Repair Parts Parts ListParts View Service Notes

CHBR-16-3 specifications

Empire Comfort Systems CHBR-16-3 is a premier choice for heating solutions, particularly favored for its combination of efficiency and convenience. This model is designed to meet the heating needs of various spaces, from homes to commercial settings, ensuring warmth and comfort even in the coldest winter months.

One of the standout features of the CHBR-16-3 is its impressive heating capacity. With an output of up to 16,000 BTUs, this unit can efficiently heat large areas, making it ideal for living rooms, basements, or even open floor plans. The powerful heat output is further complemented by a thermally efficient design, allowing the unit to operate effectively while keeping energy consumption low.

The CHBR-16-3 utilizes advanced technologies to maintain consistent temperatures. Its built-in blower system ensures an even distribution of heat throughout the space, eliminating cold spots and creating a comfortable environment. This feature is particularly beneficial in larger areas where heat can often be unevenly distributed.

Installation and ease of use are also highlights of this model. The unit is designed for straightforward installation and can be integrated into existing heating systems with relative ease. Additionally, it is equipped with a user-friendly manual control, giving users the ability to adjust settings according to their preferences. Optional remote control capabilities are also available, allowing for added convenience, especially during colder weather.

Safety is another crucial aspect of the CHBR-16-3. The unit is designed with multiple safety features, including an automatic shut-off to prevent overheating and a sealed burner to reduce the risk of carbon monoxide exposure. This attention to safety ensures peace of mind for users, allowing them to enjoy the warmth without worry.

Durability is a hallmark of Empire Comfort Systems products, and the CHBR-16-3 is no exception. Constructed from high-quality materials, this heater is designed to withstand the rigors of regular use. With proper maintenance, users can expect a long lifespan from this heating appliance.

In summary, the Empire Comfort Systems CHBR-16-3 is an excellent heating solution that stands out for its efficiency, user-friendly features, safety measures, and durable construction. Whether for residential or commercial use, this model provides reliable warmth that enhances comfort during the cold months.