Genie directlift 2060 warranty Safe-T-Beam System Self-Diagnostic Troubleshooting, Check wiring

Models: directlift 2060

1 40
Download 40 pages 36.09 Kb
Page 14
Image 14

2060-3060 eng.qxd 11/9/05 11:02 AM Page 14

TROUBLESHOOTING

Safe-T-Beam® System Self-Diagnostic Troubleshooting

Source (Red LED)

Sensor (Green LED)

Possible Problem

Solution

ON

ON

Normal operation

None required

OFF

OFF

• Power Head not powered

• Check breakers, fuses, plugs

• Wiring from Power Head bad

• Check wiring for obvious shorts

 

 

 

 

 

 

OFF

ON

• Wiring to Source missing or bad

• Check wiring

• Power has been interrupted

• Remove power and reapply

 

 

2 BLINKS, Pause

 

• Beam not aligned

• Check Source, Sensor alignment

(Repeat)

ON

• Beam obstructed

• Check for obstruction

 

 

• Sensor defective

• Contact Customer Service

2 BLINKS, Pause

OFF

• Wire to Sensor missing or bad

• Check wiring

(Repeat)

• Sensor defective

• Contact Customer Service

 

 

 

 

 

3 BLINKS, Pause

ON

• Sensor receiving interference

• Determine source of interference

(Repeat)

 

• Check for interference from sun-

 

 

 

 

 

light or a source unit on an

 

 

 

adjacent door

 

 

 

• Contact Customer Service

4 BLINKS, Pause

ON

• Source not sending pulses

• Contact Customer Service

(Repeat)

• Source defective

• Contact Customer Service

 

 

 

 

 

14

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Page 14
Image 14
Genie directlift 2060 Safe-T-Beam System Self-Diagnostic Troubleshooting, Normal operation None required, Check wiring