2060-3060 eng.qxd 11/9/05 11:02 AM Page 13

IMPORTANT

SAFETY

INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH

1READ AND FOLLOW ALL INSTRUCTIONS.

2Never let children operate or play with the Door Controls. Keep the Remote Control away from children.

3Always keep the moving door in sight and away from people and objects until the door is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.

4NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.

5Test Opener monthly. The door MUST reverse on contact with a 1-1/2" high object (or a 2" x 4" board laid flat) at the center of the doorway on the floor. After adjusting either the Force or the Limit of travel, retest the Door Opener. Failure to adjust the Opener properly may cause severe injury

or death.

6When possible use the Emergency Release only when the door is closed. Use caution when using this Release with the door open. Weak or broken springs are capable of increasing the rate of door closure and increasing the risk of severe injury or death.

7KEEP GARAGE DOORS PROPERLY BALANCED. See garage door Owner's Manual. An improperly balanced door increases the risk of severe injury or death. Have a Genie Factory Authorized Dealer make repairs to cables, spring assemblies, and other hardware.

8SAVE THESE INSTRUCTIONS.

WARNING

Use the Wall Console included with Opener. Any other wall console can cause the Opener to operate unexpectedly and the light to stop working.

MAINTENANCE

AMonthly:

Door springs and door hardware:

Oil door roller, bearings, and hinges using silicone lubricant or light oil.

WARNING

Do not operate door automatically or manually if springs are broken. Contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE.

Balance Door.

Close door.

Release Carriage Assembly from Rail Assembly by pulling the Emergency Release Knob towards the door.

Raise door manually 3'- 4' and verify that door stays at that position. See Check Step 2 on page 5.

NOTE

When the door is 3' - 4' above the ground, the door should stay open. Slight movement is acceptable. If the door moves too much, contact a Genie Factory Authorized Dealer for service or call Customer Service at

1-800-35-GENIE.

Reattach Carriage Assembly to Rail Assembly:

a.Pull the Emergency Release Knob toward Power Head.

b.Close door.

Contact Reverse Test.

Perform Adjustment 2 on page 10.

WARNING

If the door fails to reverse on contact with the board, adjust the Close Force Control as specified in Set Limit Switches and Force Controls on page 10. If the Opener still fails, contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE.

BYearly:

Wipe off old excess lubricant from Drive Screw.

Lubricate Drive Screw with Genie Lubricant (GLU-3)

NOTE

Use ONLY Genie Lubricant (GLU-3). Other lubricants may damage the Opener.

 

 

 

 

 

 

 

 

 

e

 

 

 

 

 

 

 

 

 

g

t

GLU-3

 

 

 

 

 

 

ra

 

D

 

 

 

iveGa

 

ican

 

PartN

 

 

 

 

 

 

ew

 

 

erLubr

 

 

cr

Dr

 

 

 

 

 

 

 

 

en

-3

 

 

 

 

S

 

 

p

 

 

 

 

 

 

rO

 

o.GLU

 

 

 

 

oo

 

 

 

 

 

 

Lubricant

FCC AND IC CERTIFIED

All devices comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, includ- ing interference that may cause undesired operation.

CAs needed

• Replace lightbulbs.

For Help, call 1-800-35-GENIE or visit www.geniecompany.com