Enviro Indoor Gas Fireplace owner manual Reconnect the electrical power to the unit, Flip valve

Page 12

Maintenance And Service

b)Insert a 5/32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 12), rotate it counter-clockwise until it is free and extract it.

c)Check that the screw is clean and if necessary remove dirt.

d)Flip the screw (refer to Figure 13).

e)Using the Allen wrench as shown in Figure 12, rotate the screw clockwise until a torque of 9 inch lbs. WARNING! Do not over tighten the screw. It is recommended that you grip the wrench by the short side.

f)Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o- ring visible (refer to Figure 14). If the conversion is from LPG to NG, the red o-ring of the screw must be not visible.

g)Re-attach the black protection cap that was removed in step a (Figure 11).

Figure 13: Flip valve

Figure 12: Removing valvescrew. screw.

8.Reinstall the burner, brick panels, log set, embers, and glass door. Also

refer to SECONDARY INSTALLATION - INSTALLING LOG SET AND EMBERS. When

re-installing the burner, ensure that the burner to pilot hood relationship is similar to what is shown in Figure 15. On some units you will need to pay special attention when installing

Figure 14: O-ring on valve screw.

the burner that the venturi adjustment rod is properly installed into the venturi adjustment piece welded to the burner venturi tube

9.Reconnect the main gas line if it was disconnected and open the shut-off valve at the gas line to the unit.

10.Use a small brush to apply a warm soapy water solution to all gas connections (use a half dish soap and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can be repaired by using an approved pipe thread sealant or approved Teflon tape. NEVER USE AN OPEN FLAME WHEN TESTING FOR LEAKS.

11.

Reconnect the electrical power to the unit.

 

Figure 15: Burner to pilot hood

12.

Relight the main burner in both the “HI” and “LO” positions to verify properrelationshipburner ignition.

and

operation and proper flame appearance. Also refer to SECONDARY INSTALLATION - LOG SET AND EMBERS INSTALLATION for a flame appearance picture.

13. MAKE SURE that the conversion label is installed on or close to the rating label to signify that the unit has been converted to a different fuel type.

12

Image 12
Contents Sienna Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater Sienna BV/DV NG/LPGSpecifications Dimensions33 x 46 84cm x 193 cm Operating Instructions Pilot Lighting InstructionsComponent Sound & Reason Fan controlMaintenance And Service Qualified Installers only Kit Parts List Conversion Kit InstallationReconnect the electrical power to the unit Flip valveInitial Installation SiennaDescription of Fireplace Dimension Direct Vent Width At Back Direct Vent Model Venting Fireplace Inserts Fan is thermostatically controlled and it will Gas Line Connection To Test Valve PressuresConverting a Direct Vent Fireplace to a B-VENT Fireplace Secondary Installation Left trim is so the power cord can beRun to the outside of the panel LOG SET and Ember Installation Third Stage Log Set Installation Never operate the fireplace with the glass door removed Sienna complete log set-up with embers burningBrick panel set is fragile, handle with extreme care Trouble Shooting Problem Possible Cause SolutionParts List- Unit Components NumberParts Diagram Components Parts Diagram Burner Parts List Options Parts Diagram Options Warranty To the DealerInstallation Data Sheet