Enviro Indoor Gas Fireplace owner manual Converting a Direct Vent Fireplace to a B-VENT Fireplace

Page 19

Initial Installation

QUALIFIED INSTALLERS ONLY

CONVERTING A DIRECT VENT FIREPLACE TO A B-VENT FIREPLACE:

1.Remove the Direct Vent chimney connector assembly by taking out the two (2) T-20 screws at the front of the unit. Push the assembly out from under the brackets at the back and remove (see Figure 24).

2.Remove the two (2) fresh air inlet covers from each side. Cover locations shown in Figure 24.

3.Slide the B-Vent chimney connector assembly into the same position the Direct Vent chimney connector assembly was in. Ensure the tabs are under the brackets at the back and the holes at the front line up. Secure into place with the two (2) T-20 screws at the front of the unit.

4.Disconnect the two (2) blue wires at the opening to the right of the unit and connect them to the 300°F (149°C) manual reset spill switch at the rear of the B-Vent chimney connector with the wires supplied. Refer to Figure 25.

5.Test fire the appliance and ensure proper operation. A venturi adjustment could be required to achieve an efficient flame. Improper operation or adjustment could result in Carbon Monoxide production causing personal injury or property damage.

Direct Vent

Connector Assembly

Fresh Air

Inlet Covers

Figure 24: Converting to a BV fireplace.

B-Vent

Connector Assembly

300°F (149°C)

manual reset

spill switch

Figure 25: Converting to a BV fireplace.

19

Image 19
Contents Sienna General Safety PrecautionsTable of Contents Vented GAS Fireplace Heater Sienna BV/DV NG/LPG Codes And ApprovalsDimensions Specifications33 x 46 84cm x 193 cm Pilot Lighting Instructions Operating InstructionsFan control Component Sound & ReasonMaintenance And Service Qualified Installers only Conversion Kit Installation Kit Parts ListFlip valve Reconnect the electrical power to the unitSienna Initial InstallationDescription of Fireplace Dimension Direct Vent Width At Back Direct Vent Model Venting Fireplace Inserts Fan is thermostatically controlled and it will To Test Valve Pressures Gas Line ConnectionConverting a Direct Vent Fireplace to a B-VENT Fireplace Left trim is so the power cord can be Secondary InstallationRun to the outside of the panel LOG SET and Ember Installation Third Stage Log Set Installation Sienna complete log set-up with embers burning Never operate the fireplace with the glass door removedBrick panel set is fragile, handle with extreme care Problem Possible Cause Solution Trouble ShootingNumber Parts List- Unit ComponentsParts Diagram Components Parts Diagram Burner Parts List Options Parts Diagram Options To the Dealer WarrantyInstallation Data Sheet