Enviro Indoor Gas Fireplace owner manual Brick panel set is fragile, handle with extreme care

Page 24

Secondary Installation

REMOVING THE BRICK PANEL:

The brick panel set is fragile, handle with extreme care.

The brick panel set comes pre-installed. The centre and top panel are the only panels that need to be removed if the complete gas and electrical tray assembly must be removed. The side panels may remain installed unless they are to be replaced.

1.Turn the unit off and allow the unit to cool completely.

2.Remove the fascia or louvers, open the door, and remove the log set.

3.Pull out the bottom of the centre panel while pushing up on the top panel.

4.With the center panel out, the top panel will easily come out. Just slide the top edge back out of the top lip in the firebox.

If the side and front panels must be removed, continue with steps 5, 6, 7, and 8.

5.Lift the front panel, located on the firebox bottom, from one end and remove the panel at an angle through the fire box opening.

6.Remove the log support tray by lifting the back of the tray up and pull it out from under the lip. Take care not to knock the pilot and the side brick panels.

7.Remove the two (2) T-20 screws holding the bottom of the baffle (shown in Figure 38).

8.Pull the panels out of the lips at the front of the firebox and carefully remove the panel from the unit (shown in Figure 39).

To re-install, follow the above steps in reverse. Ensure that the front and side panels are pushed as far forward as they can be before continuing with the installation.

Figure 37: Brick Panel Installation.

Figure 38: Brick Panel Installation.

Figure 39: Brick Panel Installation.

24

Image 24
Contents Sienna Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater Sienna BV/DV NG/LPGSpecifications Dimensions33 x 46 84cm x 193 cm Operating Instructions Pilot Lighting InstructionsComponent Sound & Reason Fan controlMaintenance And Service Qualified Installers only Kit Parts List Conversion Kit InstallationReconnect the electrical power to the unit Flip valveInitial Installation SiennaDescription of Fireplace Dimension Direct Vent Width At Back Direct Vent Model Venting Fireplace Inserts Fan is thermostatically controlled and it will Gas Line Connection To Test Valve PressuresConverting a Direct Vent Fireplace to a B-VENT Fireplace Secondary Installation Left trim is so the power cord can beRun to the outside of the panel LOG SET and Ember Installation Third Stage Log Set Installation Never operate the fireplace with the glass door removed Sienna complete log set-up with embers burningBrick panel set is fragile, handle with extreme care Trouble Shooting Problem Possible Cause SolutionParts List- Unit Components NumberParts Diagram Components Parts Diagram Burner Parts List Options Parts Diagram Options Warranty To the DealerInstallation Data Sheet