Enviro DV42DX owner manual KIT Components, Qnty Description

Page 16

Initial Installation

QUALIFIED INSTALLERS ONLY

Table 2: Vent termination clearances, refer to Figure 19.

Letter

Canadian Installation 1

US Installation2

Description

A

12 in (30 cm)

Clearance above grade, verandah, porch, deck, or balcony.

 

 

 

 

B

12 in (30 cm)

9 in (23 cm)

Clearance from window or door that may be opened.

 

 

 

 

C

12 in (30 cm)*

Clearance from permanently closed window (to prevent

 

 

 

condensation).

 

 

 

D

24 in (60 cm)*

Vertical clearance to ventilated soffit located above the

 

 

 

terminal, within a horizontal distance of 2 ft (60 cm) from

 

 

 

center line of terminal.

 

 

 

E

18 in (45 cm)*

Clearance to unventilated soffit.

 

 

 

F

12 in (30 cm)*

Clearance to outside corner.

 

 

 

G

12 in (30 cm)*

Clearance to inside corner.

 

 

 

 

H

3 ft (91 cm) within a height of

3 ft (91 cm) within a height of

Clearance to each side of center line extended above

 

15 ft (4.5 m) above the meter/

15 ft (4.5 m) above the meter/

meter/regulator assembly.

 

regulator assembly

regulator assembly*

 

 

 

 

 

I

3 ft (91 cm)

3 ft (91 cm)*

Radial clearance around service regulator vent outlet.

 

 

 

 

J

12 in (30 cm)

9 in (23 cm)

Clearance to non-mechanical air supply inlet to building, or

 

 

 

the combustion air inlet to any other appliance.

 

 

 

 

K

6 ft (1.83 m)

3 ft (91 cm) above if within 10

Clearance to mechanical air supply inlet.

 

 

ft (3 m) horizontally

 

 

 

 

 

L

7 ft (2.13 m)t

7 ft (2.13 m)*t

Clearance above paved sidewalk or paved driveway located

 

 

 

on public property.

 

 

 

 

M

12 in / 30 cm+

12 in / 30 cm*+

Clearance under verandah, porch, deck, or balcony.

N

12 in (30 cm)*

Clearance horizontally to any surface (such as an exterior

 

 

 

wall) for vertical terminations.

 

 

 

O

12 in (30 cm)

Clearance above roof line for vertical terminations.

 

 

 

 

1In accordance with the current CSA B149, Natural Gas and Propane Installation Code.

2 In accordance with the current ANSI Z223.1 NFPA 54, National Fuel Gas Code.

* These numbers are only estimates. Clearance in accordance with installation codes and the requirements of the gas supplier.

t A vent shall not terminate directly above a side walk or paved driveway that is located between two single family dwellings and it serves both dwellings. + Permitted only if verandah, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

NOTE: Venting terminals shall not be recessed into walls or siding.

FIREPLACE HORIZONTAL VENT KIT 50-1235:

Please read and understand these instructions before installing. Failure to follow these instructions carefully could cause property damage or personal injury.

KIT COMPONENTS:

Qnty

Description

Qnty

Description

 

 

 

 

1

Horizontal direct vent termination cap

4

Wire spacers

 

 

 

 

1

Flue collar adapter

1

4 oz tube Mill-Pac Sealant

 

 

 

 

1

Wall thimble

1

4 oz tube RTV silicone

 

 

 

 

 

1

5’

(190 cm) length of Ø4” (10 cm) double walled flex pipe

12

9/16” tech screws

1

5’

(190 cm) length of Ø65⁄8” (16.8 cm) double walled flex pipe

8

11⁄2” wood screws

 

 

 

 

 

Please ensure that all components are supplied with this kit. If components are missing or have been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if components are missing or damaged.

16

Image 16
Contents DV42DX S H E R W O O D I N D U S T R I E S L T DSafety Precautions GeneralTable of Contents Vented GAS Fireplace Heater DV42DX NG/LPG Codes And ApprovalsThis Enviro DV42DX Fireplace Specifications Installation OptionsOperating Instructions Pilot Lighting InstructionsNever USE AN Open Flame for Leak Testing To Turn GAS Fireplace OFF Component Sound & ReasonMaintenance And Service No substitute materials are allowedCleaning Decorative Surfaces To be Installed by a Qualified Service Agency only StepInitial Installation Qualified Installers onlyCorner Installation Rock or Brick Finish If the face Sheet are only approximations it is recommendedMantel Clearances KIT Components Qnty DescriptionInstallation Instructions Wire Spacer in PlaceManufacturer Trade Name Nominal Sizes Direct Vent Secure Vent Ameri Vent Description Temp SV4L6Venting terminals can not be recessed into a wall or siding Vent Configurations and Restrictor Settings Possibility of a fire Horizontal Vent TerminationAssemble Vertical Vent TerminationRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Ducting Electrical Requirements GAS Line Connection To Test Valve PressuresImportant installation notes Secondary InstallationNever operate the fireplace with the glass door removed First Stage Log Set Installation Secondary Installation Burner and FAN Removal Troubleshooting Problem Possible Cause SolutionParts List Components Reference Description Part NumberComponentsParts Diagram Parts List Options Reference Options Part NumberParts Diagram Options To the Dealer WarrantyTo the Distributor Installation Data Sheet

DV42DX specifications

The Enviro DV42DX is a highly efficient and eco-friendly ventilation device designed to enhance indoor air quality while minimizing energy consumption. This powerful product is tailored for residential and commercial applications, making it a versatile choice for those looking to improve air circulation.

One of the standout features of the Enviro DV42DX is its dual-speed fan system, which allows users to select the optimal airflow needed for various conditions. This not only provides flexibility but also contributes to energy efficiency, as it can operate at lower speeds during quieter periods. The adjustable fan settings ensure that users can tailor the device’s performance to meet their specific requirements.

Incorporating advanced filtration technologies, the Enviro DV42DX features an integrated HEPA filter that effectively captures airborne particles, allergens, and pollutants. This makes it an ideal choice for individuals with allergies or respiratory conditions, as it significantly reduces exposure to harmful elements in the air. Additionally, the unit is equipped with a charcoal filter that helps eliminate odors, further enhancing the indoor atmosphere.

The Enviro DV42DX is designed with user convenience in mind. It includes a programmable timer and a remote control, allowing users to operate the device from a distance and set it on a schedule that aligns with their routines. This feature not only enhances the ease of use but also encourages energy-saving habits by allowing the unit to operate only when needed.

Another characteristic of the Enviro DV42DX is its energy-efficient design, boasting a high Energy Star rating. The device not only reduces energy consumption but also saves users money on utility bills over time. Its durable construction and high-quality materials ensure longevity and reliable performance, making it a wise investment for maintaining a healthy living or working environment.

Safety is also a top priority for the Enviro DV42DX. The unit is equipped with built-in sensors that monitor air quality and automatically adjust operation to ensure optimal performance. This smart technology ensures that the device operates efficiently while maintaining safe levels of indoor air quality.

In conclusion, the Enviro DV42DX offers an impressive array of features and technologies that prioritize indoor air quality and energy efficiency. Its combination of advanced filtration, user-friendly controls, and smart technology makes it an indispensable tool for any environment aiming for cleaner and healthier air. Investing in the Enviro DV42DX is a step toward a more sustainable and comfortable indoor atmosphere.