Enviro DV42DX owner manual GAS Line Connection, To Test Valve Pressures

Page 28

Initial Installation

GAS LINE CONNECTION AND TESTING:

WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.

GAS LINE CONNECTION

This stove is equipped with a certified flexible pipe located on the right side of the unit terminating in a 3⁄8” male NPT fitting. Consult your local authorities codes or the CAN/CGA B 149 (1 or 2) installation code in Canada, or in the USA gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI Z223.1.

The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.

The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1⁄2 PSIG (3.45 KPa) or damage will occur to the valve.

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1⁄2 psig (3.45 KPa).

Always check for gas leaks with a soap and water solution after completing the required pressure test.

 

 

��������

 

�����

 

 

 

�������� ���

 

 

�������� ���

 

 

 

 

 

TP TH

 

OUT

IN

 

 

 

 

 

TP

H

O

 

 

I

L

OF

 

 

 

 

 

 

 

F

 

 

 

 

P

TH

 

 

I

 

 

L

 

 

T

O

 

 

 

 

 

 

NO

 

T

P

 

 

 

I

 

 

 

OL

 

 

 

 

����� ����������

������

 

��� �������

�����

����

 

����

Figure 37: Fully Labeled Gas Valve.

TO TEST VALVE PRESSURES

The pressure taps are located on the top right of the valve shown in Figure 37.

Turn set screw 1 turn counter clockwise to loosen,

Place 5/16” (8 mm) I.D. hose over pressure tap system.

Check pressures using a manometer.

When finished, release pressure, remove hose & tighten set screw.

Table 9: Pressure and BTU Information.

 

Natural Gas

Propane

Main Orifice

#37 DMS

#51 DMS

 

 

 

Manifold Pressure

3.8” W.C. (0.95 KPa)

11.0” W.C. (2.74 KPa)

 

 

 

Min. Manifold Pressure

1.1” W.C. (0.27 KPa)

2.7” W.C. (0.67 KPa)

 

 

 

Max Supply Pressure

7.0” W.C. (1.74 KPa)

13.0” W.C. (3.28 KPa)

 

 

 

Min. Supply Pressure

5.0” W.C. (1.25 KPa)

12.0” W.C. (2.98 KPa)

 

 

 

Max BTU/hr Input

38,000 BTU/hr (11.34 KW)

34,500 BTU/hr (10.11 KW)

 

 

 

Min. BTU/hr Input

20,000 BTU/hr (5.86 KW)

18,000 BTU/hr (5.28 KW)

NEVER USE AN OPEN FLAME FOR LEAK TESTING.

28

Image 28
Contents DV42DX S H E R W O O D I N D U S T R I E S L T DSafety Precautions GeneralTable of Contents Vented GAS Fireplace Heater DV42DX NG/LPG Codes And ApprovalsThis Enviro DV42DX Fireplace Specifications Installation OptionsOperating Instructions Pilot Lighting InstructionsNever USE AN Open Flame for Leak Testing To Turn GAS Fireplace OFF Component Sound & ReasonMaintenance And Service No substitute materials are allowedCleaning Decorative Surfaces To be Installed by a Qualified Service Agency only StepInitial Installation Qualified Installers onlyCorner Installation Rock or Brick Finish If the face Sheet are only approximations it is recommendedMantel Clearances KIT Components Qnty DescriptionInstallation Instructions Wire Spacer in PlaceManufacturer Trade Name Nominal Sizes Direct Vent Secure Vent Ameri Vent Description Temp SV4L6Venting terminals can not be recessed into a wall or siding Vent Configurations and Restrictor Settings Possibility of a fire Horizontal Vent TerminationAssemble Vertical Vent TerminationRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Ducting Electrical Requirements GAS Line Connection To Test Valve PressuresImportant installation notes Secondary InstallationNever operate the fireplace with the glass door removed First Stage Log Set Installation Secondary Installation Burner and FAN Removal Troubleshooting Problem Possible Cause SolutionParts List Components Reference Description Part NumberComponentsParts Diagram Parts List Options Reference Options Part NumberParts Diagram Options To the Dealer WarrantyTo the Distributor Installation Data Sheet

DV42DX specifications

The Enviro DV42DX is a highly efficient and eco-friendly ventilation device designed to enhance indoor air quality while minimizing energy consumption. This powerful product is tailored for residential and commercial applications, making it a versatile choice for those looking to improve air circulation.

One of the standout features of the Enviro DV42DX is its dual-speed fan system, which allows users to select the optimal airflow needed for various conditions. This not only provides flexibility but also contributes to energy efficiency, as it can operate at lower speeds during quieter periods. The adjustable fan settings ensure that users can tailor the device’s performance to meet their specific requirements.

Incorporating advanced filtration technologies, the Enviro DV42DX features an integrated HEPA filter that effectively captures airborne particles, allergens, and pollutants. This makes it an ideal choice for individuals with allergies or respiratory conditions, as it significantly reduces exposure to harmful elements in the air. Additionally, the unit is equipped with a charcoal filter that helps eliminate odors, further enhancing the indoor atmosphere.

The Enviro DV42DX is designed with user convenience in mind. It includes a programmable timer and a remote control, allowing users to operate the device from a distance and set it on a schedule that aligns with their routines. This feature not only enhances the ease of use but also encourages energy-saving habits by allowing the unit to operate only when needed.

Another characteristic of the Enviro DV42DX is its energy-efficient design, boasting a high Energy Star rating. The device not only reduces energy consumption but also saves users money on utility bills over time. Its durable construction and high-quality materials ensure longevity and reliable performance, making it a wise investment for maintaining a healthy living or working environment.

Safety is also a top priority for the Enviro DV42DX. The unit is equipped with built-in sensors that monitor air quality and automatically adjust operation to ensure optimal performance. This smart technology ensures that the device operates efficiently while maintaining safe levels of indoor air quality.

In conclusion, the Enviro DV42DX offers an impressive array of features and technologies that prioritize indoor air quality and energy efficiency. Its combination of advanced filtration, user-friendly controls, and smart technology makes it an indispensable tool for any environment aiming for cleaner and healthier air. Investing in the Enviro DV42DX is a step toward a more sustainable and comfortable indoor atmosphere.