Enviro DV42DX owner manual Manufacturer Trade Name Nominal Sizes

Page 18

Initial Installation

QUALIFIED INSTALLERS ONLY

through the outside wall far enough to connect onto the vent termination cap.

10.Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar adaptor previously installed into the fireplace flue outlet. Slide the Ø4” (10 cm) flex vent over the flue collar and secure with three (3) sheet metal screws evenly spaced.

11.Place a bead of high temperature silicone on the intake collar of the fireplace, slide the Ø65⁄8” (16.25 cm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced.

12.On the outside of the exterior wall, apply a bead of Mill-Pac Black sealant to the Ø4” (10 cm) pipe of the vent terminal. Slide the flex liner onto the vent terminal and secure with three (3) sheet metal screws evenly spaced.

13.Place a bead of high temperature silicone on the intake collar of the vent terminal, slide the Ø65⁄8” (16.25 cm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced.

14.Attach the vent terminal to the outside of the house using four (4) wood screws provided.

15.Light the appliance and ensure proper operation.

OTHER APPROVED VENT PARTS:

Table 3: Approved Vent Manufacturers

Manufacturer

Trade Name

Nominal Sizes

 

 

 

American Metal Products

AmeriVent Direct

4” - 6 5/8”

 

 

 

Security Chimneys International LTD

Secure Vent

4” - 6 5/8”

 

 

 

Selkirk Metalbestos

Direct-Temp

4” - 6 5/8”

 

 

 

Simpson Dura-Vent

Direct Vent GS

4” - 6 5/8”

 

 

 

The Retreat fireplace has been tested and certified for use with AMERICAN METAL PRODUCTS “AMERIVENT DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available for horizontal and vertical venting. When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the particular requirements.

WARNING: Do not mix parts from different vent manufacturers’s systems.

EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the appliance.

18

Image 18
Contents DV42DX S H E R W O O D I N D U S T R I E S L T DSafety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater DV42DX NG/LPGThis Enviro DV42DX Fireplace Specifications Installation OptionsOperating Instructions Pilot Lighting InstructionsNever USE AN Open Flame for Leak Testing To Turn GAS Fireplace OFF Component Sound & ReasonMaintenance And Service No substitute materials are allowedCleaning Decorative Surfaces To be Installed by a Qualified Service Agency only StepInitial Installation Qualified Installers onlyCorner Installation Rock or Brick Finish If the face Sheet are only approximations it is recommendedMantel Clearances KIT Components Qnty DescriptionInstallation Instructions Wire Spacer in PlaceManufacturer Trade Name Nominal Sizes Direct Vent Secure Vent Ameri Vent Description Temp SV4L6Venting terminals can not be recessed into a wall or siding Vent Configurations and Restrictor Settings Possibility of a fire Horizontal Vent TerminationAssemble Vertical Vent TerminationRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Ducting Electrical Requirements GAS Line Connection To Test Valve PressuresSecondary Installation Important installation notesNever operate the fireplace with the glass door removed First Stage Log Set Installation Secondary Installation Burner and FAN Removal Troubleshooting Problem Possible Cause SolutionParts List Components Reference Description Part NumberComponentsParts Diagram Parts List Options Reference Options Part NumberParts Diagram Options Warranty To the DealerTo the Distributor Installation Data Sheet

DV42DX specifications

The Enviro DV42DX is a highly efficient and eco-friendly ventilation device designed to enhance indoor air quality while minimizing energy consumption. This powerful product is tailored for residential and commercial applications, making it a versatile choice for those looking to improve air circulation.

One of the standout features of the Enviro DV42DX is its dual-speed fan system, which allows users to select the optimal airflow needed for various conditions. This not only provides flexibility but also contributes to energy efficiency, as it can operate at lower speeds during quieter periods. The adjustable fan settings ensure that users can tailor the device’s performance to meet their specific requirements.

Incorporating advanced filtration technologies, the Enviro DV42DX features an integrated HEPA filter that effectively captures airborne particles, allergens, and pollutants. This makes it an ideal choice for individuals with allergies or respiratory conditions, as it significantly reduces exposure to harmful elements in the air. Additionally, the unit is equipped with a charcoal filter that helps eliminate odors, further enhancing the indoor atmosphere.

The Enviro DV42DX is designed with user convenience in mind. It includes a programmable timer and a remote control, allowing users to operate the device from a distance and set it on a schedule that aligns with their routines. This feature not only enhances the ease of use but also encourages energy-saving habits by allowing the unit to operate only when needed.

Another characteristic of the Enviro DV42DX is its energy-efficient design, boasting a high Energy Star rating. The device not only reduces energy consumption but also saves users money on utility bills over time. Its durable construction and high-quality materials ensure longevity and reliable performance, making it a wise investment for maintaining a healthy living or working environment.

Safety is also a top priority for the Enviro DV42DX. The unit is equipped with built-in sensors that monitor air quality and automatically adjust operation to ensure optimal performance. This smart technology ensures that the device operates efficiently while maintaining safe levels of indoor air quality.

In conclusion, the Enviro DV42DX offers an impressive array of features and technologies that prioritize indoor air quality and energy efficiency. Its combination of advanced filtration, user-friendly controls, and smart technology makes it an indispensable tool for any environment aiming for cleaner and healthier air. Investing in the Enviro DV42DX is a step toward a more sustainable and comfortable indoor atmosphere.