Enviro EG 28 B GAS Line Connection, Never USE AN Open Flame for Leak Testing Electrical

Page 12

GAS LINE CONNECTION

ORIFICE SIZES, PRESSURE AND BTU’S

 

NATURAL GAS

PROPANE GAS

Orifice size

#42 dms

#53 dms

Manifold pressure.

3.8” wc (0.95 kPa)

11” wc (2.74 kPa)

Min. Manifold pressure.

1.1” wc (0.27 kPa)

2.7” wc (0.67 kPa)

Supply Pressure.

7.0” wc (1.74 kPa)

12” wc (2.98 kPa)

Min. Supply pressure.

5” wc (1.25 kPa)

11.5” wc (2.86 kPa)

Max. BTUH Input.

26,500

Btu/h(7.87 kW)

26,500

Btu/h(7.87 kW)

Min. BTUH Input.

13,500

Btu/h(3.9 kW)

13,500

Btu/h(3.9 kW)

Output fan off

20,700

Btu/h(6.06 kW)

21,200

Btu/h(6.21 kW)

Output fan on

21,200

Btu/h(6.21 kW)

21,700

Btu/h(6.35 kW)

WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.

NOTE: The gas line connection may be made using 3/8" rigid tubing or an approved flex connector. Since some municipalities have additional local codes it is always best to consult your local authorities and the CAN/CGA-B149 (1 or 2) Installation Code. For USA gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI.Z223.1.

UPON CONNECTION, MARK APPROPRIATE FUEL TYPE ON RATING LABEL LOCATED

ON THE INSIDE OF THE RIGHT HAND SIDE PANEL.

Manifold Pressure Tap. Inlet Pressure Tap.

Millivolt Terminals

Pilot Adjustment screw.

"HI-LOW" Burner Gas Knob.

Pilot "ON-OFF" Gas Knob.

The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1/2 PSIG (3.45 kPa) or damage will occur to the valve.

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

When using copper or flex connectors use only fittings approved for gas connections.

TO TEST

The pressure taps are located in the top right corner on the valve face (right - inlet, left - manifold pressure).

Turn set screw counter clockwise to loosen, 2 turns.

Place 5/16" hose over pressure tap system.

When finished, release pressure, remove hose &

tighten set screw.

Always check for gas leaks with a soap and water solution after completing the required pressure test.

NEVER USE AN OPEN FLAME FOR LEAK TESTING

ELECTRICAL

12

Image 12
Contents For Your Safety What to do if YOU Smell GASSafety Precautions For Your SafetyTable of Contents Assembly InstructionsCode Approvals Deciding Where to Locate Your Stove DimensionsClearances Vent Terminal Clearances Flue GAS Spill Switch VentingUsing AN Existing Chimney Manufacturers General Venting GuidelinesInstalling the Glowing Embers Installing the LogsetOperating Instructions Lighting InstructionsMaintenance and Technical Trouble ShootingProblem Possible Cause Solution Never USE AN Open Flame for Leak Testing Electrical GAS Line ConnectionOrifice SIZES, Pressure and BTU’S Natural GAS Propane GASInstalling Remote Thermostat or Wall Switch Parts and Accessories Removing or Installation of the BlowerAdjusting the Venturi Fuel ConversionWarranty To the DealerTo the Distributor Parts List Exploded EG28-143 NG EG28-145 LPG EC-019 NG, 020 LPEC-011 EG28-101Installation Data Sheet 29/2002

EG 28 B specifications

The Enviro EG 28 B is an innovative solution in the realm of environmental technology, specifically designed for efficient waste management and energy resource recovery. This advanced equipment stands out in both functionality and sustainability, making it suitable for various applications in municipal and industrial settings.

One of the main features of the Enviro EG 28 B is its robust waste processing capability. The system can handle a diverse range of materials, including organic waste, plastics, and other recyclables. This flexibility allows users to maximize the efficiency of their waste management operations, promoting a circular economy. The unit is designed with a high throughput capacity, enabling it to process large volumes of waste without sacrificing performance.

The Enviro EG 28 B utilizes cutting-edge technologies to optimize every phase of waste treatment. Integrated sensors and automated controls monitor the waste processing in real-time, ensuring that the system operates at peak efficiency. This not only maximizes the recovery of valuable resources but also minimizes energy consumption. The inclusion of advanced sorting mechanisms further enhances the unit's effectiveness, allowing for the precise separation of materials for recycling and composting.

Another characteristic that sets the Enviro EG 28 B apart is its environmentally friendly approach. The equipment is engineered to significantly reduce greenhouse gas emissions throughout its operational lifespan. It employs a closed-loop system that captures and repurposes gases generated during processing, turning potential pollutants into usable energy. This aligns with global sustainability goals and positions the Enviro EG 28 B as a leader in eco-conscious waste management solutions.

Additionally, the Enviro EG 28 B is designed with user-friendliness in mind. The intuitive interface allows for easy operation and maintenance, ensuring that operators can manage the system without extensive training. Moreover, its compact design is adaptable to various locations, allowing for installation in space-constrained environments while maintaining high operational standards.

Overall, the Enviro EG 28 B exemplifies the future of waste management technology, combining efficiency, sustainability, and ease of use. Its innovative features and technologies not only help reduce environmental impact but also provide significant economic benefits to organizations seeking to optimize their resource management practices. As the need for effective waste processing continues to grow, the Enviro EG 28 B stands ready to meet these challenges head-on.