Enviro EG 28 B owner manual Table of Contents, Code Approvals, Assembly Instructions

Page 3

 

TABLE OF CONTENTS

Safety Precautions

2

Code Approvals

3

Deciding where to locate your stove

4

Venting

6

Installation of Log Sets and Embers

8

Operating Instructions

9

Maintenance and Technical

10

Trouble Shooting

11

Gas Line Connection

12

Electrical

13

Parts and Accessories

14

Fuel Type Conversion

15

Warranty

16

Parts List

17

Exploded Views

18-19

Installation Data Sheet

20

CODE APPROVALS

This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L vent. May also be vented through a conventional chimney using a chimney liner kit.

This appliance have been tested by INTERTEK TESTING SERVICES (WH) and found to comply with the established standards for a VENTED GAS FIREPLACE HEATER in CANADA and the USA as follows:-

LISTED GAS FIRED VENTED ROOM HEATER ( EG 28 BV. Nat. & LPG. )

TESTED TO: ANSI Z21.88-1998 CSA 2.33-M98 VENTED GAS FIREPLACE HEATER CGA 2.17-M91 GAS FIRED APPLIANCES FOR USE AT HIGH ALTITUDE

SPECS:

ENVIROGAS EG 28 B VENT UNITS;

have all been certified for use with either natural or propane gases. (see control panel and rating label.)

are not for use with solid fuels.

must not be connected to a chimney flue serving a separate solid-fuel burning appliance.

are approved for bedroom or bedsitting room.

(IN CANADA: must be installed with a listed wall thermostat)

(IN USA: see current ANSI Z223.1 for installation instructions.)

must be installed in accordance with local codes if any. If none exist, use current installation code CAN/CGA b149 in Canada or ANSI Z223.1 / NFPA 54 in the USA.

must be properly connected to an approved venting system.

are approved for installation on combustible materials.

are not approved for closet or recessed installations.

FOR INSTALLATIONS ABOVE 2000 FEET (610 m).

In Canada these appliances must have the input de-rated by 10% as per the gas code.

In the USA these appliances must have the inputs de-rated by 4% for every 1000 feet (305m) above sea level.

ASSEMBLY INSTRUCTIONS

Remove the packaging from the appliance, check to make sure there is no damage. If damage is found, PREPARATION FOR INSTALLATION

Please report it to both the carrier and your dealer as soon as possible.

Before beginning, carefully check the glass door and the log set

3

Image 3
Contents What to do if YOU Smell GAS For Your SafetyFor Your Safety Safety PrecautionsTable of Contents Assembly InstructionsCode Approvals Deciding Where to Locate Your Stove DimensionsClearances Vent Terminal Clearances Venting Flue GAS Spill SwitchManufacturers General Venting Guidelines Using AN Existing ChimneyInstalling the Logset Installing the Glowing EmbersLighting Instructions Operating InstructionsTrouble Shooting Maintenance and TechnicalProblem Possible Cause Solution Natural GAS Propane GAS Never USE AN Open Flame for Leak Testing ElectricalGAS Line Connection Orifice SIZES, Pressure and BTU’SInstalling Remote Thermostat or Wall Switch Removing or Installation of the Blower Parts and AccessoriesFuel Conversion Adjusting the VenturiWarranty To the DealerTo the Distributor Parts List Exploded EG28-101 EG28-143 NG EG28-145 LPGEC-019 NG, 020 LP EC-01129/2002 Installation Data Sheet

EG 28 B specifications

The Enviro EG 28 B is an innovative solution in the realm of environmental technology, specifically designed for efficient waste management and energy resource recovery. This advanced equipment stands out in both functionality and sustainability, making it suitable for various applications in municipal and industrial settings.

One of the main features of the Enviro EG 28 B is its robust waste processing capability. The system can handle a diverse range of materials, including organic waste, plastics, and other recyclables. This flexibility allows users to maximize the efficiency of their waste management operations, promoting a circular economy. The unit is designed with a high throughput capacity, enabling it to process large volumes of waste without sacrificing performance.

The Enviro EG 28 B utilizes cutting-edge technologies to optimize every phase of waste treatment. Integrated sensors and automated controls monitor the waste processing in real-time, ensuring that the system operates at peak efficiency. This not only maximizes the recovery of valuable resources but also minimizes energy consumption. The inclusion of advanced sorting mechanisms further enhances the unit's effectiveness, allowing for the precise separation of materials for recycling and composting.

Another characteristic that sets the Enviro EG 28 B apart is its environmentally friendly approach. The equipment is engineered to significantly reduce greenhouse gas emissions throughout its operational lifespan. It employs a closed-loop system that captures and repurposes gases generated during processing, turning potential pollutants into usable energy. This aligns with global sustainability goals and positions the Enviro EG 28 B as a leader in eco-conscious waste management solutions.

Additionally, the Enviro EG 28 B is designed with user-friendliness in mind. The intuitive interface allows for easy operation and maintenance, ensuring that operators can manage the system without extensive training. Moreover, its compact design is adaptable to various locations, allowing for installation in space-constrained environments while maintaining high operational standards.

Overall, the Enviro EG 28 B exemplifies the future of waste management technology, combining efficiency, sustainability, and ease of use. Its innovative features and technologies not only help reduce environmental impact but also provide significant economic benefits to organizations seeking to optimize their resource management practices. As the need for effective waste processing continues to grow, the Enviro EG 28 B stands ready to meet these challenges head-on.