MHP manual Hearth Installation, Common Materials And Factors, Vermont Castings EWF36A, 20005167

Page 16
Hearth Installation

Vermont Castings EWF36A

Examples of wall shield insulation:

1. Manville - CERAFORM 126, K=.27, 1/2 inches thick

2. EH2416, K = .458,

1 inch thick required.

Hearth Installation

A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 26 for mini- mum dimensions and mounting detail.

NOTE: Hearth Extension must not cover the air inlet opening of a fireplace.

The hearth extension described in Figure 26 must be a durable noncombustible material with a minimum (total) Rt value of 1.09; refer to Figure 24 for examples. The overall height (above a combustible floor), depth and width must be as indicated, with the extension centered

Noncombustible material with a lower R value may be used, provided thickness of material is sufficiently greater to maintain an equivalent (total) thermal resis- tance (Rt).

Example of Determining Hearth Extension Equivalents

To determine the thickness required for any new mate- rial:

NEW

K of new material (per inch)

thickness

required =

 

X

of listed

 

thickness

K of listed material (per inch)

material

Example for Common Brick

T (new) = 5.0/0.458 x 0.50 in. = 5.46 in. (new required thickness).

to the fireplace opening.

The top of insulation must be covered with a non-com- bustible decorative covering or a piece of .018” mini- mum sheet metal, to protect hearth extension material. (Fig. 26)

Secure the hearth extension to the floor to prevent shifting, using trim molding or other similar means at three (3) outer edges. Seal crack between the fireplace hearth and hearth extension with a noncombustible

Wall Covering COMMON MATERIALS AND FACTORS

Noncombus- tible Decorative Facing

Seal all cracks between fireplace sur- round (steel) and wall materials with noncom- bustible material.

2 x 4 Header - Do not notch at standoffs

NOTE: No material may cover black cast face.

material. (Figs. 25 and 26)

WARNING: Hearth extension must be installed in accordance with Figure 25. Top of hearth extension must be level with bottom of fireplace.

Alternate noncombustible materials may be used providing the (total) thermal resistance (Rt value) of the alternate material employed is greater than or equal to R = 1.09 Thermal resistance (R) or thermal conductivity (K), may be obtained from manufacturer of the material. Factors are related by the formula K = 1/R. (Fig. 24)

T = given thickness

R = thermal resistance for a given thickness (T) K = thermal conductivity

COMMON MATERIALS AND FACTORS

Cast Front

Noncombustible

Decorative Cover-

ing

FP1202

Safety Strips - Must be

overlapped 1/2” minimum

Fig. 25 Sealing gaps.

MATERIAL

K*

R

MINIMUM

THICKNESS

EH2416

0.916

2.18

1.0 in.**

(CFM Corporation)

 

 

 

 

 

Common Brick

5.0

0.10

5.46 in.**

 

 

 

 

 

R Value is for 1/2 inch.

*Units of K = BTU/SQ FT/HR/˚F/IN ** Thickness of Listed Material

FP533ADD

Fig. 24 Hearth extension material factors.

16

20005167

Image 16
Contents Homeowner’s Installation and Operating Manual EWF36A FireplaceDo Not Discard This Manual: Retain for Future Use Table of Contents IntroductionVermont Castings EWF36A 20005167Safety Information PrecautionsDescription DraftsSpecifications EWF36AEWF36A Woodburning Fireplace Vermont Castings EWF36AVermont Castings EWF36A Chase Installation20005167 Chimney Requirements - Offset Installations 30˚ Elbow OffsetsIllustration Key Vermont Castings EWF36APlanning Information Mounting the FireplacePlanning the Chimney Run The Ten Foot RuleInstallation Chase InstallationChimney Supports Insulating Fireplace Enclosure for Cold ClimatesStraight-UpChimney Installation Offset InstallationFraming EB1 Receptacle HookupPositioning, Safety Strips Securing the Fireplace Ceiling Chimney Hole Possible ObstructionsCutting the Hole Framing the Ceiling HoleInstallation Instructions Installating Outside Air KitInstallation Precautions Vermont Castings EWF36AVermont Castings EWF36A Installing the Chimney System20005167 Installing the Firestop Spacer Proper Firestop Spacer InstallationContinue Installing Pipe to Complete Run in the Ceiling HoleInstall Remainder of Chimney Sections Install Top Housing or TerminationInstalling Chimney in a Chase Penetrating the RoofFinish Wall MantelsSide Wall Protection Vermont Castings EWF36AHearth Installation COMMON MATERIALS AND FACTORSVermont Castings EWF36A 20005167Minimum Hearth Extension Dimensions Vermont Castings EWF36AMinimum Wall Clearances 20005167Operation Attach HandlesEWF36A Controls Primary Air ControlUse the Air Control Settings The FanGlass Doors Burn Only High-QualityWoodStarting and Maintaining a Wood Fire Reloading and Reviving a Wood FireSpecial Tactics for Cold-ClimateHeating Vermont Castings EWF36AVermont Castings EWF36A Remove and Store Ash Safely20005167 Maintenance Cleaning the GlassAdjust the Door Latch Periodically Inspection and CleaningWhen to Suspect a Combustor Problem Removing, Cleaning or Replacing the CombustorHow to Replace Gaskets Inspecting the CombustorA Clean Chimney System is Safer and Works Better The Chimney SystemReplacing the Door Gaskets Replace Damaged Door Glass ImmediatelyMaintenance Schedule Yearly Spring CleaningVermont Castings EWF36A Fireplace DailyVermont Castings EWF36A Chimney Components20005167 EWF36A Fireplace Vermont Castings EWF36A20005167 DescriptionEWF36A Fireplace continued Vermont Castings EWF36A20005167 DescriptionOptional Accessories Fan KitTrim Kits Screen KitVermont Castings EWF36A 20005167Limited 3 Year Warranty Warranty20005167 MHSC 149 Cleveland Drive • Paris, Kentucky