TABLE OF CONTENTS

Page

Safety Label

 

Specifications

2

Safety Label

4

Installation

 

General Installation Information

5

Installation Checklist

5

Minimum Clearances to Combustibles

6

Optional Outside Air

6

- Outside Air through Bottom of Pedestal

6

- Outside Air through Rear of Pedestal

7

Draft Hood

7

High Elevation

7

Venting

7

- Venting Requirements

7

- Flue Mounting Bracket

7

- Vent Terminations

7

- Installation into Existing Woodstove Flue System

7

Gas Connection

8

System Data

8

Gas Pressure Test

8

Conversion from Natural Gas to Propane

9

Conversion to Lower Btu

10

Log Installation

10

Door Installation and Door Latch

12

U38 Louver Installation

12

Test for Flue Spillage

12

Optional Wall Thermostat

12

Optional Remote Control Installation

13

Final Check

13

Wiring Diagram

13

 

Page

Operating Instructions

 

Operating Instructions

14

Lighting Instructions

14

Shutdown Instructions

14

First Fire

14

Convection Fan Operation

14

Flame Height Adjustment

14

Copy of Lighting Plate Instructions

15

Pilot Adjustment

16

Aeration Adjustment

16

Normal Operating Sounds of Gas Appliances

16

Maintenance

 

Maintenance Instructions

17

Log Replacement

17

Gold Plated Doors

17

Door and Glass Gasket

17

Glass Replacement

17

- Mitred Door

17

- Panel Door

18

Fan Maintenance

18

- Replacing Fan

18

RemovingValve

19

Parts List

20

Warranty

 

Warranty

23

Regency U38 ULTIMATE Freestanding Gas Heater

3

Image 3
Contents Ultimate U38 Freestanding Gas Stove To the New Owner U38-NG & U38-LPRegency U38 Ultimate Freestanding Gas Stove Table of Contents Copy of the Safety Label for the U38 Freestanding Gas Stove Safety LabelBefore YOU Start InstallationGeneral Safety Information Installation ChecklistU38-NG&U38-LPREFERENCE DimensionsOptional Outside AIR Clearances to CombustiblesHigh Elevation Draft Hood VentingGAS Pipe Pressure Testing GAS ConnectionHigh Elevation U38-NG Pilot assembly is now accessible for Steps 4 to Conversion from Natual GAS to PropaneBurner Orifice Propane Conversion Kit Contains LOG SET InstallationConversion to Lower BTU Rating for U38 Natural Gas Conversion Kit 730-920 ContainsNotch Pins on Rear Log SupportLava rock PinCutoutOptional Wall Thermostat Front Door InstallationLouver Installation Test for Flue SpillageFinal Check Optional Remote ControlWiring Thermostat Wire TableOperating Instructions To Turn OFF GAS Appliance For Your Safety Read Before LightingCopy of the Lighting Plate Instructions Lighting InstructionsPilot Adjustment Aeration AdjustmentNormal Operating Sounds GAS Appliances Maintenance FAN Maintenance Installing GlassPaneldoor Magnetic type screwdriver Removing ValveParts List U38 Main AssemblyDescription U38 Burner & LOG Assembly U38 Door Assemblies Warranty Lifetime WarrantyInstaller Please complete the following information