Regency Wraps U38-LP GAS Connection, GAS Pipe Pressure Testing, High Elevation U38-NG

Page 8

INSTALLATION

GAS CONNECTION

The gas line can be rigid pipe, or to make installation easier, use a listed flexible connec- tor if allowed by local codes. Copper may also be used if approved by local codes.

The gas connection at the valve is 3/8" NPT. For minimum and maximum supply pressure see the System Data Table.

System Data

U38 with 40,000 BTU

U38-NG: For 0 to 2000 feet altitude

U38-LP: For 0 to 4500 feet alttitude

Burner Inlet Orifice Sizes:

 

 

 

Natural Gas

Propane

Burner

#31

#50

 

 

 

 

 

Max. Input

 

 

 

Natural Gas

40,000 Btu/h

Propane

38,000 Btu/h

 

 

 

 

Min. Input

 

 

 

Natural Gas

22,000 Btu/h

Propane

20,000 Btu/h

 

 

 

Supply Pressure

 

 

Natural Gas

min. 5" w.c.

Propane

min. 12" w.c.

 

 

 

Manifold Pressure

 

 

Natural Gas

3.8"

+/- 0.2" w.c.

Propane

11"

+/- 0.2" w.c.

Electrical: 120 V. 1.13A 60Hz.

Circulation: Variable speed fan, 125/75 CFM.

Log Set: Ceramic fiber, 7 per set.

System Data:

HIGH ELEVATION - U38-NG

For 2,000 - 4,500 feet altitude

Burner Inlet Orifice Sizes:

Natural Gas Burner #33

Max. Input Rating 36,000 Btu/h

Min. Input Rating 19,000 Btu/h

System Data

U38 Converted to 30,000 Btu

For 0 to 4500 feet altitude

 

Burner Inlet Orifice Sizes:

 

 

 

Natural Gas

Propane

 

Burner

#37

#52

 

 

 

 

 

 

 

Max. Input

 

 

 

 

Natural Gas

30,000 Btu/h

 

Propane

30,000 Btu/h

 

 

 

 

 

 

Min. Input

 

 

 

 

Natural Gas

15,000 Btu/h

 

Propane

15,000 Btu/h

 

 

 

 

 

 

Supply Pressure

 

 

 

 

Natural Gas

min. 5" w.c.

 

Propane

min. 12" w.c.

 

 

 

 

 

Manifold Pressure

 

 

 

Natural Gas

3.8"

+/- 0.2" w.c.

 

Propane

11"

+/- 0.2" w.c.

Electrical: 120 V. 1.13A 60Hz.

Circulation: Variable speed fan, 125/75 CFM.

Log Set: Ceramic fiber, 7 per set.

GAS PIPE PRESSURE

TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pres- sures over 1/2 psig (14" w.c.).

The manifold pressure is controlled by a regu- lator built into the gas control, and should be checked at the pressure test point.

Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.

1)Make sure the valve is in the "OFF" position.

2)Loosen the "IN" (# 7) and/or "OUT" (# 6) pressure tap(s), turning counterclockwise with a 1/8" wide flat screwdriver.

3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.

4)Light the pilot and turn the valve to "ON" position.

5)The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label.

6)When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Screw should be snug, but do not over tighten.

S.I.T. Valve Description

1)Gas cock knob

2)Manual high/low adjustment

3)Pilot Adjustment

4)Thermocouple Connection

5)Main Operator

6)Outlet Pressure Tap

7)Inlet Pressure Tap

8)Pilot Outlet

9)Main Gas Outlet

10)Flange Securing Screw Holes

11)Alternative TC Connection Point

12)Thermoelectric Unit

13)Additional Valve Mounting Hole

8

Regency U38 ULTIMATE Freestanding Gas Stove

Image 8
Contents Ultimate U38 Freestanding Gas Stove Regency U38 Ultimate Freestanding Gas Stove To the New OwnerU38-NG & U38-LP Table of Contents Safety Label Copy of the Safety Label for the U38 Freestanding Gas StoveInstallation General Safety InformationInstallation Checklist Before YOU StartDimensions Optional Outside AIRClearances to Combustibles U38-NG&U38-LPREFERENCEDraft Hood Venting High ElevationHigh Elevation U38-NG GAS Pipe Pressure TestingGAS Connection Burner Orifice Pilot assembly is now accessible for Steps 4 toConversion from Natual GAS to Propane LOG SET Installation Conversion to Lower BTU Rating for U38Natural Gas Conversion Kit 730-920 Contains Propane Conversion Kit ContainsPins on Rear Log Support Lava rockPinCutout NotchFront Door Installation Louver InstallationTest for Flue Spillage Optional Wall ThermostatOptional Remote Control WiringThermostat Wire Table Final CheckOperating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsLighting Instructions To Turn OFF GAS ApplianceNormal Operating Sounds GAS Appliances Pilot AdjustmentAeration Adjustment Maintenance Paneldoor FAN MaintenanceInstalling Glass Removing Valve Magnetic type screwdriverDescription Parts ListU38 Main Assembly U38 Burner & LOG Assembly U38 Door Assemblies Warranty Warranty LifetimeInstaller Please complete the following information