Regency Wraps U38-NG, U38-LP installation manual Pilot Adjustment, Aeration Adjustment

Page 16

OPERATING INSTRUCTIONS

PILOT ADJUSTMENT

Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile and 1 around the thermo- couple, and 1 flowing across the rear of the burner (it does not have to be touching the burner).

Note: If you have an incorrect flame pattern, contact your Regency dealer for further instructions.

Top View of pilot flame

Incorrect flame pattern will have small, proba- bly yellow flames, not coming into proper con- tact with the rear of the burner or thermopile.

Top View of pilot flame

AERATION

ADJUSTMENT

The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.

 

U38 with 40,000 Btu/h

U38-NG

Natural Gas:

1/4" open

U38-LP

Propane:

1/2" open

 

U38 with 30,000 Btu/h

U38-NG

Natural Gas

3/16" open

U38-LP

Propane

3/8" open

The aeration adjustment gears are located on the right side of the burner box and can be accessed from the side or from the front when the louvers are removed.

To adjust the aeration: use the allen key to turn the turning gear which will adjust the air shutter. Open the air shutter for a blue flame or close it for a yellower flame.

Clockwise to open,

counter-clockwise to close.

Caution: Carbon will be produced if the air shutter is closed too much.

Note: Any damage due to carboning re- sulting from improperly setting the aeration controls is NOT covered under warranty.

Note: Aeration Adjustment should only be performed by an authorized Regency Installer at the time of installation or service.

NORMAL OPERATING

SOUNDS OF

GAS APPLIANCES

It is possible that you will hear some sounds from your gas appliance. This is perfectly nor- mal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are nor- mal operating sounds and should not be considered as defects in your appliance.

Blower:

Regency gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON. This sound will increase or decrease in volume depending on the speed setting of your fan speed control.

Burner Tray:

The burner tray is positioned directly under the burner tube(s) and logs and is made of a different gauge material from the rest of the firebox and body. Therefore, the varying thick- nesses of steel will expand and contract at slightly different rates which can cause "tick- ing" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fireboxes.

Blower Thermodisc:

When this thermally activated switch turns ON it will create a small "clicking" sound. This is the switch contacts closing and is normal.

Pilot Flame:

While the pilot flame is on it can make a very slight "whisper" sound.

Gas Control Valve:

As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.

Unit Body/Firebox:

Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.

16

Regency U38 ULTIMATE Freestanding Gas Stove

Image 16
Contents Ultimate U38 Freestanding Gas Stove U38-NG & U38-LP To the New OwnerRegency U38 Ultimate Freestanding Gas Stove Table of Contents Safety Label Copy of the Safety Label for the U38 Freestanding Gas StoveInstallation General Safety InformationInstallation Checklist Before YOU StartDimensions Optional Outside AIRClearances to Combustibles U38-NG&U38-LPREFERENCEDraft Hood Venting High ElevationGAS Connection GAS Pipe Pressure TestingHigh Elevation U38-NG Conversion from Natual GAS to Propane Pilot assembly is now accessible for Steps 4 toBurner Orifice LOG SET Installation Conversion to Lower BTU Rating for U38Natural Gas Conversion Kit 730-920 Contains Propane Conversion Kit ContainsPins on Rear Log Support Lava rockPinCutout NotchFront Door Installation Louver InstallationTest for Flue Spillage Optional Wall ThermostatOptional Remote Control WiringThermostat Wire Table Final CheckOperating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsLighting Instructions To Turn OFF GAS ApplianceAeration Adjustment Pilot AdjustmentNormal Operating Sounds GAS Appliances Maintenance Installing Glass FAN MaintenancePaneldoor Removing Valve Magnetic type screwdriverU38 Main Assembly Parts ListDescription U38 Burner & LOG Assembly U38 Door Assemblies Warranty Warranty LifetimeInstaller Please complete the following information