Regency Wraps U38-NG, U38-LP Copy of the Safety Label for the U38 Freestanding Gas Stove

Page 4

SAFETY LABEL

This is a copy of the label that accompanies each ULTIMATE Freestanding Gas Stove. We have printed a copy of the contents here for your review. The safety label is located on the inside of the drop down pedestal door.

NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Copy of the Safety Label for the U38 Freestanding Gas Stove

Listed: GAS FIRED VENTED ROOM HEATER

Tested to: CGA 2.17-M91, ANSI Z21.88-1998/ CSA 2.33-M98

Certified for/Certifiée pour: CANADA and USA Report No. 476-1846-00 (Oct. 2000)

DO NOT REMOVE THIS LABEL/NE PAS ENLEVER CETTEÉTIQUETTE

222

Serial No./No de serie

Model/Modele: U38-NG

Model/Modele: U38-LP

FACTORY EQUIPPED FOR NATURAL GAS: Model U38-NG

ÉQUIPÉ À L'UISINE POUR GAZ NATUREL:

Minimum

supply pressure 5"

WC/C.E.

(1.25kPa)

Pression d’alimentation minimum

 

 

 

 

 

 

 

 

 

Manifold pressure High

3.8"

 

 

WC/C.E.

(0.94kPa)

Pression

tubulure

d’échappement

 

élevée

Manifold pressure Low

1.1"

 

 

WC/C.E. (0.27kPa) Pression

tubulure

déchappement

 

basse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model U38

-NG: Factory Equipped for Altitude 0-2000 ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice size

#31

 

 

 

DMS

 

 

 

 

 

 

 

 

 

Dimensions de l’orifice

 

 

 

 

 

 

 

 

 

Altitude

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-2000

ft/pi

(0-610)

 

 

 

L'altitude

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum

 

Input

40,000

Btu/h

(11.73Kwh)

Débit calorifique maximum selon

 

 

 

 

 

 

 

 

 

Minimum Input

21,000

Btu/h

(6.15Kwh)

Débit calorifique minimum selon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model U38

-NG: Convertible for Altitude 2000-4500 ft.

Transforme en haute l'altitude Gaz Naturel:

Orifice size

#33

 

 

 

DMS

 

 

 

 

 

 

 

 

 

Dimensions de l’orifice

 

 

 

 

 

 

 

 

 

Altitude

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000-4500ft/pi

(610-1370m) L'altitude

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum

 

Input

36,000

Btu/h

(10.55Kw)

Débit calorifique maximum selon

 

 

 

 

 

 

 

 

 

Minimum

Input

19,000

Btu/h

(5.57Kwh)

Débit calorifique minimum selon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model U38-NG: Convertible to 30,000 Btu for Altitude 0-4500 ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice size

#37

 

 

 

DMS

 

 

 

 

 

 

 

 

 

Dimensions de l’orifice

 

 

 

 

 

 

 

 

 

Maximum

 

Input

30,000

Btu/h

(8.78Kwh)

Débit calorifique maximum selon

 

 

 

 

 

 

 

 

 

Minimum

Input

15,000

Btu/h

(4.39Kwh)

Débit calorifique minimum selon

 

 

 

 

 

 

 

 

 

FACTORY EQUIPPED FOR PROPANE GAS: Model U38-LP

ÉQUIPÉ À L'UISINE POUR GAZ PROPANE:

Minimum

supply pressure 12"

WC/C.E.

(3.00Kpa)

Pression d’alimentation minimum

 

 

 

 

 

 

 

 

 

Manifold pressure High

11"

 

 

 

WC/C.E.

(2.74Kpa)

Pression

tubulure

d’échappement

 

élevée

Manifold

pressure Low

2.9"

 

 

WC/C.E.

(0.72Kpa)

Pression

tubulure

d’échappement

 

basse

Orifice size

50

 

 

 

 

DMS

 

 

 

 

 

 

 

 

 

Dimensions de l’orifice

 

 

 

 

 

 

 

 

 

Altitude

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-2,000 ft/pi

(0-610m)

L’altitude

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum

 

Input

38,000

BTU/h

(11.14Kw/h) Débit calorifique maximum selon

 

 

 

 

 

 

 

 

 

Minimum Input

20,000

BTU/h

(5.86Kw/h)

Débit calorifique minimum selon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model U38-LP: Convertible to 30,000 Btu for Altitude 0-4500 ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice size

#52

 

 

 

DMS

 

 

 

 

 

 

 

 

 

Dimensions de l’orifice

 

 

 

 

 

 

 

 

 

Maximum

 

Input

30,000

Btu/h

(8.78Kwh)

Débit calorifique maximum selon

 

 

 

 

 

 

 

 

 

Minimum

Input

15,000

Btu/h

(4.39Kwh)

Débit calorifique minimum selon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Clearances

to Combustibles

Degagement minimum des materiaux combustibles:

A7-1/2" /190mm

B6" /155mm

E2" /50mm Min. Ceiling Height from top of unit / Min. Plafond Hauteur en haut de l'appareil: 36" / 914 mm

GAS FIRED VENTED ROOM HEATER

This appliance must be installed in accordance with local codes, if any; If not, follow: ANSI Z223.1/CAN/ CGA-B149 Electrical Supply (115 V, 1.13 A, 60 Hz)

Not for use with solid fuel.

POLE R GAZ RADIATEUR VENTILE

Cet appareil doit être installé conformement aux exigences des codes locaux, s'il n'existe aucun code local, se conformer à la norme: ANSI Z223.1 / CAN 1-B149 en vigueur. Alimentation électrique. Ne doit pas être utilisé avec un combustible solide.

FPI Fireplace Products International Ltd., Delta, BC, Canada Made in CANADA / FABRIQUE AU CANADA 918-029 rev. 10/03

For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts. For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.

4

Regency U38 ULTIMATE Freestanding Gas Stove

Image 4
Contents Ultimate U38 Freestanding Gas Stove U38-NG & U38-LP To the New OwnerRegency U38 Ultimate Freestanding Gas Stove Table of Contents Safety Label Copy of the Safety Label for the U38 Freestanding Gas StoveInstallation General Safety InformationInstallation Checklist Before YOU StartDimensions Optional Outside AIRClearances to Combustibles U38-NG&U38-LPREFERENCEDraft Hood Venting High ElevationGAS Connection GAS Pipe Pressure TestingHigh Elevation U38-NG Conversion from Natual GAS to Propane Pilot assembly is now accessible for Steps 4 toBurner Orifice LOG SET Installation Conversion to Lower BTU Rating for U38Natural Gas Conversion Kit 730-920 Contains Propane Conversion Kit ContainsPins on Rear Log Support Lava rockPinCutout NotchFront Door Installation Louver InstallationTest for Flue Spillage Optional Wall ThermostatOptional Remote Control WiringThermostat Wire Table Final CheckOperating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsLighting Instructions To Turn OFF GAS ApplianceAeration Adjustment Pilot AdjustmentNormal Operating Sounds GAS Appliances Maintenance Installing Glass FAN MaintenancePaneldoor Removing Valve Magnetic type screwdriverU38 Main Assembly Parts ListDescription U38 Burner & LOG Assembly U38 Door Assemblies Warranty Warranty LifetimeInstaller Please complete the following information