Regency Wraps U38-LP, U38-NG installation manual Removing Valve, Magnetic type screwdriver

Page 19

MAINTENANCE

If your valve requires maintenance or replace- ment, follow these instructions:

NOTE: Always shut off the gas supply before removing the valve.

1)Open front pedestal door and unhook chain. You may want to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn't scratch the paint. See diagram below.

2)Undo the six screws holding the control panel in place.

3)Disconnect all wires from the back of the panel and then remove panel. You should lay the panel on a soft cloth so it doesn't get marked up. See diagram below.

4)Remove the two outside frame pieces by removing two screws per side. See dia- gram below.

REMOVING VALVE

5) Carefully remove the logs and lava rock.

6)At this point you should disconnect the gas at the valve.

7)Remove the burner by removing the two 1/4" hex head screws. See diagram be- low.

Note: Use a

magnetic type screwdriver.

8)Remove eight 1/4" hex head screws hold- ing the burner tray assembly in place.

9)Carefully lift the burner tray assembly out.

10)To replace the burner tray assembly, sim- ply reverse these instructions.

Regency U38 ULTIMATE Freestanding Gas Heater

19

Image 19
Contents Ultimate U38 Freestanding Gas Stove U38-NG & U38-LP To the New OwnerRegency U38 Ultimate Freestanding Gas Stove Table of Contents Copy of the Safety Label for the U38 Freestanding Gas Stove Safety LabelBefore YOU Start InstallationGeneral Safety Information Installation ChecklistU38-NG&U38-LPREFERENCE DimensionsOptional Outside AIR Clearances to CombustiblesHigh Elevation Draft Hood VentingGAS Connection GAS Pipe Pressure TestingHigh Elevation U38-NG Conversion from Natual GAS to Propane Pilot assembly is now accessible for Steps 4 toBurner Orifice Propane Conversion Kit Contains LOG SET InstallationConversion to Lower BTU Rating for U38 Natural Gas Conversion Kit 730-920 ContainsNotch Pins on Rear Log SupportLava rock PinCutoutOptional Wall Thermostat Front Door InstallationLouver Installation Test for Flue SpillageFinal Check Optional Remote ControlWiring Thermostat Wire TableOperating Instructions To Turn OFF GAS Appliance For Your Safety Read Before LightingCopy of the Lighting Plate Instructions Lighting InstructionsAeration Adjustment Pilot AdjustmentNormal Operating Sounds GAS Appliances Maintenance Installing Glass FAN MaintenancePaneldoor Magnetic type screwdriver Removing ValveU38 Main Assembly Parts ListDescription U38 Burner & LOG Assembly U38 Door Assemblies Warranty Lifetime WarrantyInstaller Please complete the following information