Regency Wraps F38-LPG2 Installation Checklist, Clearances to Combustibles, Draft Diverter

Page 6

INSTALLATION

14)This unit can be installed on a solid combus- tible surface like a wood fl oor as well as on carpeting.

INSTALLATION

CHECKLIST

1)Check Clearances to Combustibles. Refer to the "Clearance to Combustibles" section.

2)Install flueing. Refer to the "Flueing" section.

3)Make gas connections. Refer to the "Gas Connection" section.

Test the pilot. Must be as per diagram in the "Pilot Adjustment" section.

4)If necessary, convert NG to LPG. Refer to the "Conversion from NG to LPG" section

5)Test Gas Pressure. Refer to the "Gas Pipe Pressure Testing" section.

6)Install log set. Refer to the "Log Set Installation" section.

7)Install Front Door. Refer to the "Front Door Installation" section.

8)Test for fl ue spillage (draft test). Refer to the "Test for Flue Spillage" section.

9)Install Optional Features. Refer to the following sections where applicable:

a.Optional Wall Thermostat

b.Optional Remote Control

10)Final check. Refer to the "Final Check" section.

Before leaving this unit with the customer, the installer must ensure that the appliance is fi r- ing correctly and operation fully explained to

CLEARANCES TO

COMBUSTIBLES

The clearances listed below are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. (The farthest distance is correct if the two clear- ances do not coincide.) For example, if the appliance is set as indicated in one of the fi gures but the connector is too close, move the stove until the correct clearance to the connector is obtained.

This unit can be installed on a solid combustible surface like a wood fl oor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with unit) is installed.

This appliance may be installed only with the clearances as shown in the situations pictured. Do not combine clearances from one type of installation with another in order to achieve closer clearances.

Use the minimum clearances shown in the diagrams below for all installations.

F38-NG2 & F38-LPG2 Clearances

A Side Wall to Unit

7-1/2" / 190 mm

B Back Wall to Unit

6" / 155 mm

E Side Wall to Unit

2" / 50 mm

F38-NG2 & F38-LPG2

Reference Dimensions

CBack Wall to Flue Centerline 10-3/4" / 273 mm D Side Wall to Flue Centerline 20-1/2" / 520 mm F Side Wall to Flue Centerline 11" / 280 mm

Minimum ceiling

height is 36" / 914 mm

from top of unit.

If further reduced clear-

ances are needed, ob-

tain requirements for

construction of a pro-

tected wall from your

local building authori-

ties and their allowable

reductions of the listed

clearances.

DRAFT DIVERTER

This heater has a draft diverter built in. It must not be altered, obstructed, or blocked in any way, and the unit must be installed so that the draft diverter is in the same atmospheric pressure zone as the combustion air inlet to the burner. This heater must be properly connected to a

ueing system. This heater is equipped with a

ue safety shutoff system.

WARNING: Operation of this heater when not connected to a properly installed and maintained flueing system or tampering with the flue safety shutoff system can result in carbon monoxide (CO) poisoning and pos- sible death.

FLUEING

This heater is a fl ued appliance and must be connected to a chimney/fl ue in accordance with the installation codes.

customer.

This includes:

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label) after burning appliance for 15 minutes.

2)If required, adjusting the primaryair to ensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning or that results in damage is not the responsibility of the manu- facturer.

Note: The rear pedestal cover plate must always be fitted for safety. Electrical connections inside.

For your safety this heater is equipped with a

ue safety switch designed to sense incorrect

ueing and react by shutting down the gas sup- ply. This thermally actuated switch is located within the draft diverter and will detect either a blockedchimneyorbackdraftconditionwherethe chimney fl ow has reversed. If this switch shuts the unit down, it indicates a drafting problem that

must be identifi ed and rectifi ed without delay

-the thermally activated switch must never be bypassed or disconnected as a hazardous or deadly condition can result.

6

Regency F38-2 Freestanding Gas Stove

Image 6
Contents Manual Please Keep These Instructions For Future ReferenceTo the New Owner Table of Contents Safety Label General Information InstallationGeneral Safety Information Before YOU StartDraft Diverter Installation ChecklistClearances to Combustibles FlueingFlueing Requirements GAS Pipe Pressure TestingGAS Connection T. Valve Description#52 and tighten Conversion KIT# 731-968 from NG to LPGLPG Conversion Kit Contains Qty Reverse steps 3 toAeration Adjustment LOG SET InstallationF38-2 with 38 mj E02-45 F02-47 A02-65 D02-46 B02-56 C02-44 Front Door Installation Test for Flue SpillageFinal Check 14 GA 15.24 16 GA 18 GA 20 GA 22 GAWiring Operating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsPilot Adjustment Normal Operating Sounds GAS AppliancesMaintenance Install door catch plate FAN MaintenanceInstalling Glass Withoutthefanaccesspanelsecurely Place and correctly sealedRemoving Valve Parts List F38-2 Main AssemblyPart# Aust. New Zealand Description F38-2 Burner & LOG Assembly F38-2 Door Assemblies DescriptionWarranty Western Australia Eastern Australia

F38-NG2, F38-LPG2 specifications

Regency Wraps is known for its innovative approach to creating stylish and functional clothing storage solutions. Among their notable offerings are the F38-NG2 and F38-LPG2 garment bags. These bags blend practicality and aesthetics, catering to the needs of individuals looking to store and transport their garments with care and style.

The F38-NG2 is designed with a focus on durability and protection. Made from high-quality nylon fabric, it provides excellent resistance to wear and tear while also being lightweight for easy handling. One of the key features of this garment bag is its spacious interior, allowing users to store multiple garments without worrying about creasing or damage. The innovative design includes breathable ventilation that helps prevent odors and keeps clothes fresh during travel or storage. Additionally, the translucent window enables quick visibility of the contents, eliminating the hassle of searching through a packed bag.

On the other hand, the F38-LPG2 caters to a slightly different demographic with its luxurious polyester fabric. This elegant material not only enhances the bag’s aesthetic appeal but also adds a layer of protection against dust, dirt, and moisture. The F38-LPG2 is particularly well-suited for formal attire, such as evening gowns and suits. Its padded interior offers extra cushioning for delicate fabrics, ensuring that garments remain in pristine condition. Like its counterpart, this bag features a convenient clear window, allowing users to identify garments at a glance.

Both the F38-NG2 and F38-LPG2 incorporate advanced technologies, such as anti-static linings. These linings help reduce static cling, providing an extra level of care for garments made from synthetic materials. Additionally, both bags come with sturdy zippers and reinforced handles for enhanced durability, ensuring that they can withstand the rigors of frequent use.

In conclusion, the Regency Wraps F38-NG2 and F38-LPG2 garment bags are ideal choices for individuals seeking quality and functionality in their clothing storage solutions. With their thoughtful designs, high-quality materials, and protective features, these bags are perfect for traveling, seasonal storage, or simply keeping your wardrobe organized. Whether you prefer the rugged advantage of the F38-NG2 or the sophisticated elegance of the F38-LPG2, both options reflect Regency Wraps' commitment to quality and innovation in garment care.