Regency FG37-NG, FG37-LPG installation manual Operating Instructions

Page 19

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

Before operating this appliance, proceed through the following check list.

1)Read and understand these Instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the three pieces of door glass are properly positioned. Never operate the appliance with any of the glass removed or with the door open.

5)Verify that all flueing and the cap is unob- structed.

6)Verify log placement.

RESETTING

THE UNIT

1)Open the pedestal door on the unit.

2)Press the reset button for approximately 3 seconds and release. The reset button is located on the unit's control panel.

3)Wait for approximately 3 seconds and the pilot sparks can be heard and seen. It would take 2 to 3 seconds for the flame to be lit.

SHUTDOWN

INSTRUCTIONS

1)Press the ON/OFF button once.

2)Turn off all electric power to the appliance if service is to be performed.

FAN OPERATION

Set the fan speed on the control panel located in behind the pedestal door to adjust fan to the desired speed.

Control Panel

Pressing and releasing the plus (+) FAN button will change the fan speed as follows:

OFF -> LOW -> MEDIUM -> HIGH -> OFF, etc.

Pressing and releasing the minus (-) FAN button will be the reverse of the above.

LIGHTING

INSTRUCTIONS

1)Plug the power cord into a power outlet.

2)Press and release the ON/OFF button once to start the unit.

3)After approximately 3 seconds the spark ignition system will spark for 40 seconds to light the main burner.

4)If the main burner does not light, reset the unit.

FIRST FIRE

The FIRST FIRE in your heater is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with the fan on.

When first operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac- turing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.

NOTE: The main burner will always start on "HIGH" and resume it's last setting after 20 seconds of operation.

NOTE: When the glass is cold and the appli- ance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DONOTATTEMPTTOCLEANTHEGLASS WHILE IT IS STILL HOT!

DO NOT BURN THE APPLIANCE WITH- OUTTHEGLASSFRONTINPLACE.

ADJUSTING FLAME

HEIGHT

There are six flame settings that can be adjust- ed by pressing and releasing the plus (+) and minus (-) FLAME button.

The FLAME setting button is located on the control panel in behind the pedestal door.

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

19

Image 19
Contents Please Keep These Instructions For Future Reference ManualTo the New Owner Table of Contents Data Plate Save These Instructions InstallationSpecifications General Safety InformationCombustion and Ventilation AIR Installation ChecklistLocating Your Regency GAS Stove Clearances to CombustiblesClearance k in mm Exterior Flue Termination LocationsFluing Fluing Installation PrecautionsSafety Precautions for Installer Planning Your Fluing InstallationOffset to Vertical Terminations Vertical Terminations With Co-linear Flex SystemFlue Restrictor Position Snorkel Terminations Horizontal InstallationsDiagram Optional ComponentsHint Apply sealant to female end Below Grade Snorkel InstallationGAS Connection Vertical Termination with CO-LINEAR Flex SystemJumper Location Pilot Orifice Extrusion Assembly TubeBurner Orifice Antenna Control Box CoverCable Electric Modulator Adjusting the Outlet PressureLOG SET Installation Aeration AdjustmentNG 10mm open LPG 10mm open Notch Cutout PinCutoutNotch Louvre Installation GAS Pipe Pressure TestingT. Valve Description Wiring Optional Remote ControlFinal Check Operating Instructions Summary Controls Pilot AdjustmentNormal Operating Sounds GAS Appliances Settle on the floor Copy of the Lighting Plate Instructions918-332a Maintenance Instructions MaintenanceGOLD-PLATED Doors LOG Replacement Latch AdjustmentGlass Replacement Rectly sealed FAN MaintenanceManual Switch Reset Cables Pin Ground Molex Connector WireRemoving Valve Tray Electronic Components Parts List Parts ListFG37 Main Assembly FG37 Burner & LOG Assembly FG37 Door Assemblies FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater Exclusions WarrantyWarranty Lifetime Conditions

FG37-NG, FG37-LPG specifications

The Regency FG37-LPG and FG37-NG are premium gas fireplaces that blend elegance with cutting-edge technology, making them ideal for modern homes. Designed by Regency, a leader in the fireplace industry, these models offer both aesthetic appeal and highly efficient heating capabilities.

The FG37-LPG is powered by liquid propane, while the FG37-NG utilizes natural gas, providing versatile options to meet different customer needs. Both models feature a sleek, contemporary design that complements various interior styles, making them a focal point in any living space. The large viewing area allows for an expansive display of flames, contributing to a warm, inviting atmosphere.

One of the standout features of the Regency FG37 series is its advanced heating technology. The fireplaces employ a high-efficiency burner system that maximizes heat output while minimizing gas consumption. This efficiency not only leads to lower energy bills but also reduces environmental impact, aligning with sustainability goals.

Additionally, the Regency FG37 models feature advanced flame control technology. Users can easily adjust the flame intensity, allowing for a custom heating experience that suits personal preferences and room sizes. This versatility makes them suitable for a variety of applications, from cozy family rooms to expansive open-concept spaces.

For added convenience, the fireplaces are equipped with a modern electronic ignition system, ensuring reliable and hassle-free startup. Customers appreciate the included remote control, which provides effortless operation from the comfort of their seats. As an optional upgrade, the Regency Smart Home Control system allows for integration with smart home devices, enabling users to manage their fireplace from their smartphones or tablets.

Safety is paramount in the design of the FG37-LPG and FG37-NG. Both models come with a built-in safety shutoff valve, ensuring that the gas supply is automatically cut off in the event of an emergency. The units also feature a glass door that remains cool to the touch, providing peace of mind for households with pets and children.

Overall, the Regency FG37-LPG and FG37-NG epitomize the perfect merger of style, efficiency, and safety. With their striking design, advanced technologies, and user-friendly features, these gas fireplaces are an excellent choice for anyone seeking to enhance their home with the luxury and warmth of a modern fireplace.